9 resultados para Loop closing

em Reposit


Relevância:

10.00% 10.00%

Publicador:

Resumo:

An unfavorable denture-bearing area could compromise denture retention and stability, limit mastication, and possibly alter masticatory motion. The purpose of this study was to evaluate the masticatory movements of denture wearers with normal and resorbed denture-bearing areas. Completely edentulous participants who received new complete dentures were selected and divided into 2 groups (n=15) according to the condition of their denture-bearing areas as classified by the Kapur method: a normal group (control) (mean age, 65.9 ± 7.8 years) and a resorbed group (mean age, 70.2 ± 7.6 years). Masticatory motion was recorded and analyzed with a kinesiographic device. The patients masticated peanuts and Optocal. The masticatory movements evaluated were the durations of opening, closing, and occlusion; duration of the masticatory cycle; maximum velocities and angles of opening and closing; total masticatory area; and amplitudes of the masticatory cycle. The data were analyzed by 2-way ANOVA and the Tukey honestly significant difference post hoc test (α=.05). The group with a resorbed denture-bearing area had a smaller total masticatory area in the frontal plane and shorter horizontal masticatory amplitude than the group with normal denture-bearing area (P<.05). Denture wearers with resorbed denture-bearing areas showed reduced jaw motion during mastication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Patients with myofascial pain experience impaired mastication, which might also interfere with their sleep quality. The purpose of this study was to evaluate the jaw motion and sleep quality of patients with myofascial pain and the impact of a stabilization device therapy on both parameters. Fifty women diagnosed with myofascial pain by the Research Diagnostic Criteria were enrolled. Pain levels (visual analog scale), jaw movements (kinesiography), and sleep quality (Epworth Sleepiness Scale; Pittsburgh Sleep Quality Index) were evaluated before (control) and after stabilization device use. Range of motion (maximum opening, right and left excursions, and protrusion) and masticatory movements during Optosil mastication (opening, closing, and total cycle time; opening and closing angles; and maximum velocity) also were evaluated. Repeated-measures analysis of variance in a generalized linear mixed models procedure was used for statistical analysis (α=.05). At baseline, participants with myofascial pain showed a reduced range of jaw motion and poorer sleep quality. Treatment with a stabilization device reduced pain (P<.001) and increased both mouth opening (P<.001) and anteroposterior movement (P=.01). Also, after treatment, the maximum opening (P<.001) and closing (P=.04) velocities during mastication increased, and improvements in sleep scores for the Pittsburgh Sleep Quality Index (P<.001) and Epworth Sleepiness Scale (P=.04) were found. Myofascial pain impairs jaw motion and quality of sleep; the reduction of pain after the use of a stabilization device improves the range of motion and sleep parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A monomeric basic PLA2 (PhTX-II) of 14149.08 Da molecular weight was purified to homogeneity from Porthidium hyoprora venom. Amino acid sequence by in tandem mass spectrometry revealed that PhTX-II belongs to Asp49 PLA2 enzyme class and displays conserved domains as the catalytic network, Ca2+-binding loop and the hydrophobic channel of access to the catalytic site, reflected in the high catalytic activity displayed by the enzyme. Moreover, PhTX-II PLA2 showed an allosteric behavior and its enzymatic activity was dependent on Ca2+. Examination of PhTX-II PLA2 by CD spectroscopy indicated a high content of alpha-helical structures, similar to the known structure of secreted phospholipase IIA group suggesting a similar folding. PhTX-II PLA2 causes neuromuscular blockade in avian neuromuscular preparations with a significant direct action on skeletal muscle function, as well as, induced local edema and myotoxicity, in mice. The treatment of PhTX-II by BPB resulted in complete loss of their catalytic activity that was accompanied by loss of their edematogenic effect. On the other hand, enzymatic activity of PhTX-II contributes to this neuromuscular blockade and local myotoxicity is dependent not only on enzymatic activity. These results show that PhTX-II is a myotoxic Asp49 PLA2 that contributes with toxic actions caused by P. hyoprora venom.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Human Neks are a conserved protein kinase family related to cell cycle progression and cell division and are considered potential drug targets for the treatment of cancer and other pathologies. We screened the activation loop mutant kinases hNek1 and hNek2, wild-type hNek7, and five hNek6 variants in different activation/phosphorylation statesand compared them against 85 compounds using thermal shift denaturation. We identified three compounds with significant Tm shifts: JNK Inhibitor II for hNek1(Δ262-1258)-(T162A), Isogranulatimide for hNek6(S206A), andGSK-3 Inhibitor XIII for hNek7wt. Each one of these compounds was also validated by reducing the kinases activity by at least 25%. The binding sites for these compounds were identified by in silico docking at the ATP-binding site of the respective hNeks. Potential inhibitors were first screened by thermal shift assays, had their efficiency tested by a kinase assay, and were finally analyzed by molecular docking. Our findings corroborate the idea of ATP-competitive inhibition for hNek1 and hNek6 and suggest a novel non-competitive inhibition for hNek7 in regard to GSK-3 Inhibitor XIII. Our results demonstrate that our approach is useful for finding promising general and specific hNekscandidate inhibitors, which may also function as scaffolds to design more potent and selective inhibitors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate pathologic features with implications on surgical radicality in women treated with radical hysterectomy and pelvic lymphadenectomy for cervical cancer stage IA1 with lymph vascular space invasion (LVSI) and stage IA2 by correlating findings in conization and hysterectomy specimens. Women with cervical cancer stage IA1 with LVSI and stage IA2 diagnosed by loop electrosurgical excisional procedure or cold knife conization were treated with radical hysterectomy and pelvic lymphadenectomy from January 1999 to December 2011 in 2 institutions. Fifty patients were enrolled: 40 with stage IA2 and 10 with stage IA1 with LVSI. Median age was 43 (30-67) years. All patients underwent cervical conization for diagnosis (45 loop electrosurgical excisional procedure, 5 cold knife). Lymph vascular space invasion was detected in 15 patients (30%). Two patients had positive pelvic nodes. No parametrial involvement was detected in the entire cohort. Positive margins were present in 35 patients, and residual disease was detected in 22 patients (44%). Positive margins predicted residual disease at radical hysterectomy (P = 0.02). Medium follow-up time was 51 months. One patient developed a pelvic recurrence, and there were no disease-related deaths. Patients with positive margins in cone biopsy specimens have an increased risk of residual disease at radical hysterectomy and require careful evaluation before conservative surgery. Pelvic lymph node evaluation is essential because lymph node metastasis may occur even in early stages. The lack of parametrial invasion in this study reinforces the knowledge that the select group of patients with microinvasive cervical carcinoma stages IA1 LVSI and stage IA2 have a very low risk of parametrial infiltration. Less radical surgery can be carefully considered for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed the development of a low cost servo-valve that answers to an electronic control signal, for variable rates liquid inputs application. A literature research to define which valve type should be used was made. A mechanically activated proportional valve with an electronically controlled servo-engine was designed and evaluated. Since developed the servo-valve, the system was submited to a number of tests .The evaluation of its behavior was obtained in terms of repeatability, hystheresis and linearity. The test was accomplished in a bench, specially developed for this aim. As a result, were obtained three curves of opening percentage as function of flow rate, describing three opening and closing increments in two different work pressures. The servo-valve presented a good repeatability, reasonable hysteresis and a typically quadratic curve. This one maintained the low cost target. These results were very satisfied because the non-linearity and the hysteresis could be easily corrected by software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article deals with the theme of teacher training from the historical and theoretical perspectives. In the first part, the historical focus is introduced and the trajectory of teacher training in Brazil is examined, dividing it into six periods beginning with the passing of the Law of Schools of First Letters in 1827 and closing with the promulgation of the new law for national education in 1996. The second part deals with theoretical aspects, considering the two basic models of teacher training, their implications for the training of teachers of primary and pre-school education, the dilemma resulting from the contraposition between the two models and the way for overcoming it and concluding with observations on the training of teachers for special education.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different brands and batches of brazilian regular and instant coffee were purchased in supermarkets of Campinas? city and analysed for caffeine content. The method used involved extraction with boiling water, clarification with saturated basic acetate and determination by high performance liquid cromatography. Analysis was carried out using a Model 6000 A solvent delivery system (Waters associates), and a Model 7125 sample injector system (Reodyne, Inc.) with a 5µl sample loop. The system was also equipped with a Waters Model M440 absorbance detector set at 254 nm. A Merck ODS 5µm column (15 cm x 4.6 mm i.d.) was used to separate the caffeine. The mobile phase was methanol:water (25:75, v/v). The caffeine content varied for different brands and types of coffee and according to the beverage preparation technique. Values in the range of 0.43 to 0.85 mg/ml and 0.61 to 0.82 mg/ml were determined in regular and instant coffee, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física