2 resultados para Collaborative Software
em Reposit
Resumo:
The purpose of this study was to evaluate the presence of myofibroblasts, frequently associated with a more aggressive neoplastic behavior, in oral tongue squamous cell carcinoma (TSCC) of young patients and to compare with the distribution observed in older patients. Tumor samples from 29 patients younger than 40 years old affected by TSCC were retrieved and investigated for the presence of stromal myofibroblasts by immunohistochemical reactions against α smooth muscle actin, and the results obtained were compared to TSCC cases affecting older patients. No positive reaction could be found in the stromal areas devoid of neoplastic tissue, whereas myofibroblasts were present in 58.6% of the lesions in young patients and in 75.9% of the older ones. No significant difference was found when comparing the invasive front and the overall stroma of both groups, and no correlation could be obtained with stromal α smooth muscle actin expression, higher tumor grades or clinical stage (P > .05). There was no significant difference between the presence of stromal myofibroblasts of TSCC affecting young and old individuals.
Resumo:
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.