10 resultados para vacuum-pump

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two single crystalline surfaces of Au vicinal to the (111) plane were modified with Pt and studied using scanning tunneling microscopy (STM) and X-ray photoemission spectroscopy (XPS) in ultra-high vacuum environment. The vicinal surfaces studied are Au(332) and Au(887) and different Pt coverage (θPt) were deposited on each surface. From STM images we determine that Pt deposits on both surfaces as nanoislands with heights ranging from 1 ML to 3 ML depending on θPt. On both surfaces the early growth of Pt ad-islands occurs at the lower part of the step edge, with Pt ad-atoms being incorporated into the steps in some cases. XPS results indicate that partial alloying of Pt occurs at the interface at room temperature and at all coverage, as suggested by the negative chemical shift of Pt 4f core line, indicating an upward shift of the d-band center of the alloyed Pt. Also, the existence of a segregated Pt phase especially at higher coverage is detected by XPS. Sample annealing indicates that the temperature rise promotes a further incorporation of Pt atoms into the Au substrate as supported by STM and XPS results. Additionally, the catalytic activity of different PtAu systems reported in the literature for some electrochemical reactions is discussed considering our findings.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Asthma, laryngitis and chronic cough are atypical symptoms of the gastroesophageal reflux disease. To analyze the efficacy of laparoscopic surgery in the remission of extra-esophageal symptoms in patients with gastroesophageal reflux, related to asthma. Were reviewed the medical records of 400 patients with gastroesophageal reflux disease submitted to laparoscopic Nissen fundoplication from 1994 to 2006, and identified 30 patients with extra-esophageal symptoms related to asthma. The variables considered were: gender, age, gastroesophageal symptoms (heartburn, acid reflux and dysphagia), time of reflux disease, treatment with proton pump inhibitor, use of specific medications, treatment and evolution, number of attacks and degree of esophagitis. Data were subjected to statistical analysis, comparing the pre- and post-surgical findings. The comparative analysis before surgery (T1) and six months after surgery (T2) showed a significant reduction on heartburn and reflux symptoms. Apart from that, there was a significant difference between the patients with daily crises of asthma (T1 versus T2, 45.83% to 16.67%, p=0.0002) and continuous crises (T1, 41.67% versus T2, 8.33%, p=0.0002). Laparoscopic Nissen fundoplication was effective in improving symptoms that are typical of reflux disease and clinical manifestations of asthma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report the STAR measurements of dielectron (e(+)e(-)) production at midrapidity (|y(ee)|<1) in Au+Au collisions at √[s(NN)]=200  GeV. The measurements are evaluated in different invariant mass regions with a focus on 0.30-0.76 (ρ-like), 0.76-0.80 (ω-like), and 0.98-1.05 (ϕ-like)   GeV/c(2). The spectrum in the ω-like and ϕ-like regions can be well described by the hadronic cocktail simulation. In the ρ-like region, however, the vacuum ρ spectral function cannot describe the shape of the dielectron excess. In this range, an enhancement of 1.77±0.11(stat)±0.24(syst)±0.33(cocktail) is determined with respect to the hadronic cocktail simulation that excludes the ρ meson. The excess yield in the ρ-like region increases with the number of collision participants faster than the ω and ϕ yields. Theoretical models with broadened ρ contributions through interactions with constituents in the hot QCD medium provide a consistent description of the dilepton mass spectra for the measurement presented here and the earlier data at the Super Proton Synchrotron energies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most important properties of quantum dots (QDs) is their size. Their size will determine optical properties and in a colloidal medium their range of interaction. The most common techniques used to measure QD size are transmission electron microscopy (TEM) and X-ray diffraction. However, these techniques demand the sample to be dried and under a vacuum. This way any hydrodynamic information is excluded and the preparation process may alter even the size of the QDs. Fluorescence correlation spectroscopy (FCS) is an optical technique with single molecule sensitivity capable of extracting the hydrodynamic radius (HR) of the QDs. The main drawback of FCS is the blinking phenomenon that alters the correlation function implicating in a QD apparent size smaller than it really is. In this work, we developed a method to exclude blinking of the FCS and measured the HR of colloidal QDs. We compared our results with TEM images, and the HR obtained by FCS is higher than the radius measured by TEM. We attribute this difference to the cap layer of the QD that cannot be seen in the TEM images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The establishment of the most stable structures of eight membered rings is a challenging task to the field of conformational analysis. In this work, a series of 2-halocyclooctanones were synthesized (including fluorine, chlorine, bromine and iodine derivatives) and submitted to conformational studies using a combination of theoretical calculation and infrared spectroscopy. For each compound, four conformations were identified as the most important ones. These conformations are derived from the chair-boat conformation of cyclooctanone. The pseudo-equatorial (with respect to the halogen) conformer is preferred in vacuum and in low polarity solvents for chlorine, bromine and iodine derivatives. For 2-fluorocyclooctanone, the preferred conformation in vacuum is pseudo-axial. In acetonitrile, the pseudo-axial conformer becomes the most stable for the chlorine derivative. According to NBO calculations, the conformational preference is not dictated by electron delocalization, but by classical electrostatic repulsions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this work is to study theoretically stereoelectronic aspects of the interaction between heme and artemisinin in the transitional heme-artemisinin complex. Through semi-empirical calculations using the PM3 method, the potential energy barrier of artemisinin rotation relative to heme in the heme-artemisinin complex was studied in vacuum and in the partially solvated state. The minimum heat of formation obtained for the complex with and without water molecules is -702.39 and -100.86 kcal mol-1, respectively, which corresponds to the dihedral angle C-Fe-O1-O2 of 43.93º and 51.90º around the iron-oxygen O1 bond, respectively. The water molecules bind to heme via 13 hydrogen bonds and O-H O and 6 C-H O interactions, which accounts for -67.23 kcal mol-1. It is observed that the inclusion of water molecules does not affect significantly the stability of the heme-artemisinin complex.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A solid-phase in-line extraction system for water samples containing low levels of emerging contaminants is described. The system was specially developed for large volume samples (up to 4 L) using commercial solid-phase extraction (SPE) cartridges. Four sets containing PTFE-made connectors, brass adapters and ball valves were used to fit SPE cartridges and sample bottles to a 4-port manifold attached to a 20 L carboy. A lab-made vacuum device was connected to the manifold cap. The apparatus is robust and less expensive than the typical available system. Its also provides less experimental handling, avoiding cross contamination and sample losses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of vegetal impurities in sugarcane delivered to sugarmills as green and dry leaves is a problem not only because they are non-value materials to be processed along with sugarcane stalks, but also because they can rise the color of the clarified juice and, consequently, the color of the sugar produced, with a reduction of its quality for the market. Another problem is the mud volume sedimented in the clarifiers, which also can result in a larger recirculation and greater volume of filtrate juice, with higher losses of sucrose and utilization of the vacuum rotary filters. The objective of this work was to observe the effect of the presence of green and dry leaves on sugarcane juice clarification, related to a control treatment with the addition of fiber extracted from the stalks. The experiments were planned based on the addition of quantities of fibrous sources in order to formulate samples with absolute increase of 0.25 , 0.50 and 0.75 percentual points over the fiber content of the sugarcane stalks (control treatment). The juice clarification was conducted with a laboratory clarifier. The clarified juice color and the mud volume were evaluated. The presence of green leaves caused higher color and mud volume due to the extraction of non-sucrose components of the leaves. Soluble compounds of dry leaves were also extracted, though not detected by juice analysis. The addition of the fiber extracted from the stalks did not induce alterations in the clarification process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Quality traits of boneless rib cut (L. dorsi muscle) from Nelore young bulls. To study the meat quality traits of Nelore breed young bulls, and the effect of age (690-780 days) on them, 113 animals were slaughtered after 109 days of intensive feeding with 20% concentrate and 80% roughage. All the carcasses were graded at the slaughter floor by the Federal Inspection and chilled for 24 hours (Tinitial=5°C, Tfinal=2°C). Fifty one half carcasses (right side), type B - B R A S I L `s grading system - from animals of 23 to 26 months were boned and separated into commercial cuts. Two steaks (2.5cm thick) were removed from each boneless rib cut (m. L. dorsi), vacuum packaged and aged for 7 days (0-2°C). The pH varied from 5.44 to 5.83 and only two samples had pH ³ 5.70. The L* (brightness) average value was 34.85. The water and fat content were 75.65% and 1.71%, respectively. The average WB shear force was 6.70kg, and it was not affected by age (690-734 days), but presented a trend (t test, p=0.22) for increasing values between 735 and 780 days. Animal age did not affect other quality traits (t test, p>0.20). It was concluded that the rib cut from Nelore young bulls may not have a good acceptability in exigent markets, and that carcasses graded B, presumed to be the best grade, do not necessarily present the best meat quality characteristics.