12 resultados para test device

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the study was to develop a culturally adapted translation of the 12-item smell identification test from Sniffin' Sticks (SS-12) for the Estonian population in order to help diagnose Parkinson's disease (PD). A standard translation of the SS-12 was created and 150 healthy Estonians were questioned about the smells used as response options in the test. Unfamiliar smells were replaced by culturally familiar options. The adapted SS-12 was applied to 70 controls in all age groups, and thereafter to 50 PD patients and 50 age- and sex-matched controls. 14 response options from 48 used in the SS-12 were replaced with familiar smells in an adapted version, in which the mean rate of correct response was 87% (range 73-99) compared to 83% with the literal translation (range 50-98). In PD patients, the average adapted SS-12 score (5.4/12) was significantly lower than in controls (average score 8.9/12), p < 0.0001. A multiple linear regression using the score in the SS-12 as the outcome measure showed that diagnosis and age independently influenced the result of the SS-12. A logistic regression using the SS-12 and age as covariates showed that the SS-12 (but not age) correctly classified 79.0% of subjects into the PD and control category, using a cut-off of <7 gave a sensitivity of 76% and specificity of 86% for the diagnosis of PD. The developed SS-12 cultural adaption is appropriate for testing olfaction in Estonia for the purpose of PD diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An unfavorable denture-bearing area could compromise denture retention and stability, limit mastication, and possibly alter masticatory motion. The purpose of this study was to evaluate the masticatory movements of denture wearers with normal and resorbed denture-bearing areas. Completely edentulous participants who received new complete dentures were selected and divided into 2 groups (n=15) according to the condition of their denture-bearing areas as classified by the Kapur method: a normal group (control) (mean age, 65.9 ± 7.8 years) and a resorbed group (mean age, 70.2 ± 7.6 years). Masticatory motion was recorded and analyzed with a kinesiographic device. The patients masticated peanuts and Optocal. The masticatory movements evaluated were the durations of opening, closing, and occlusion; duration of the masticatory cycle; maximum velocities and angles of opening and closing; total masticatory area; and amplitudes of the masticatory cycle. The data were analyzed by 2-way ANOVA and the Tukey honestly significant difference post hoc test (α=.05). The group with a resorbed denture-bearing area had a smaller total masticatory area in the frontal plane and shorter horizontal masticatory amplitude than the group with normal denture-bearing area (P<.05). Denture wearers with resorbed denture-bearing areas showed reduced jaw motion during mastication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with myofascial pain experience impaired mastication, which might also interfere with their sleep quality. The purpose of this study was to evaluate the jaw motion and sleep quality of patients with myofascial pain and the impact of a stabilization device therapy on both parameters. Fifty women diagnosed with myofascial pain by the Research Diagnostic Criteria were enrolled. Pain levels (visual analog scale), jaw movements (kinesiography), and sleep quality (Epworth Sleepiness Scale; Pittsburgh Sleep Quality Index) were evaluated before (control) and after stabilization device use. Range of motion (maximum opening, right and left excursions, and protrusion) and masticatory movements during Optosil mastication (opening, closing, and total cycle time; opening and closing angles; and maximum velocity) also were evaluated. Repeated-measures analysis of variance in a generalized linear mixed models procedure was used for statistical analysis (α=.05). At baseline, participants with myofascial pain showed a reduced range of jaw motion and poorer sleep quality. Treatment with a stabilization device reduced pain (P<.001) and increased both mouth opening (P<.001) and anteroposterior movement (P=.01). Also, after treatment, the maximum opening (P<.001) and closing (P=.04) velocities during mastication increased, and improvements in sleep scores for the Pittsburgh Sleep Quality Index (P<.001) and Epworth Sleepiness Scale (P=.04) were found. Myofascial pain impairs jaw motion and quality of sleep; the reduction of pain after the use of a stabilization device improves the range of motion and sleep parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess binocular detection grating acuity using the LEA GRATINGS test to establish age-related norms in healthy infants during their first 3 months of life. In this prospective, longitudinal study of healthy infants with clear red reflex at birth, responses to gratings were measured at 1, 2, and 3 months of age using LEA gratings at a distance of 28 cm. The results were recorded as detection grating acuity values, which were arranged in frequency tables and converted to a one-octave scale for statistical analysis. For the repeated measurements, analysis of variance (ANOVA) was used to compare the detection grating acuity results between ages. A total of 133 infants were included. The binocular responses to gratings showed development toward higher mean values and spatial frequencies, ranging from 0.55 ± 0.70 cycles per degree (cpd), or 1.74 ± 0.21 logMAR, in month 1 to 3.11 ± 0.54 cpd, or 0.98 ± 0.16 logMAR, in month 3. Repeated ANOVA indicated differences among grating acuity values in the three age groups. The LEA GRATINGS test allowed assessment of detection grating acuity and its development in a cohort of healthy infants during their first 3 months of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data on record regarding weight variation in depot-medroxyprogesterone acetate (DMPA) and levonorgestrel-releasing intrauterine system (LNG-IUS) users are controversial. To date, no studies have yet evaluated weight variation in DMPA and LNG-IUS users in up to ten years of use compared to non-hormonal contraceptive users. A retrospective study analysed weight variations in 2138 women using uninterruptedly DMPA (150 mg intramuscularly, three-monthly; n = 714), the LNG-IUS (n = 701) or a copper-intrauterine device (Cu-IUD; n = 723). At the end of the first year of use, there was a mean weight increase of 1.3 kg, 0.7 kg and 0.2 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively, compared to weight at baseline (p < 0.0001). After ten years of use, the mean weight had risen by 6.6 kg, 4.0 and 4.9 kg among the DMPA-, LNG-IUS- and Cu-IUD users, respectively. DMPA-users had gained more weight than LNG-IUS- (p = 0.0197) and than Cu-IUD users (p = 0.0294), with the latter two groups not differing significantly from each other in this respect (p = 0.5532). Users of hormonal and non-hormonal contraceptive methods gained a significant amount of weight over the years. DMPA users gained more weight over the treatment period of up to ten years than women fitted with either a LNG-IUS or a Cu-IUD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study sought to analyse the behaviour of the average spinal posture using a novel investigative procedure in a maximal incremental effort test performed on a treadmill. Spine motion was collected via stereo-photogrammetric analysis in thirteen amateur athletes. At each time percentage of the gait cycle, the reconstructed spine points were projected onto the sagittal and frontal planes of the trunk. On each plane, a polynomial was fitted to the data, and the two-dimensional geometric curvature along the longitudinal axis of the trunk was calculated to quantify the geometric shape of the spine. The average posture presented at the gait cycle defined the spine Neutral Curve. This method enabled the lateral deviations, lordosis, and kyphosis of the spine to be quantified noninvasively and in detail. The similarity between each two volunteers was a maximum of 19% on the sagittal plane and 13% on the frontal (p<0.01). The data collected in this study can be considered preliminary evidence that there are subject-specific characteristics in spinal curvatures during running. Changes induced by increases in speed were not sufficient for the Neutral Curve to lose its individual characteristics, instead behaving like a postural signature. The data showed the descriptive capability of a new method to analyse spinal postures during locomotion; however, additional studies, and with larger sample sizes, are necessary for extracting more general information from this novel methodology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To assess the neurodevelopmental functions (cognition, language and motor function) of survivors of twin-twin transfusion syndrome (TTTS). Method Observational cross-sectional study of a total of 67 monochorionic diamniotic twins who underwent fetoscopic laser coagulation (FLC) for treatment of TTTS. The study was conducted at the Center for Investigation in Pediatrics (CIPED), Universidade Estadual de Campinas. Ages ranged from one month and four days to two years four months. Bayley Scales of Infant and Toddler Development Screening Test-III, were used for evaluation. Results Most children reached the competent category and were classified as having appropriate performance. The preterm children scored worse than term infants for gross motor subtest (p = 0.036). Conclusion The majority of children reached the expected development according to their age. Despite the good neurodevelopment, children classified at risk should be monitored for development throughout childhood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigated the cytotoxic and genotoxic potential of water from the River Paraíba do Sul (Brazil) using Allium cepa roots. An anatomo-morphological parameter (root length), mitotic indices, and frequency of micronuclei were analysed. Eight bulbs were chosen at random for treatment for 24 to 120 hours with the River water collected in the years of 2005 and 2006 from sites in the cities of Tremembé and Aparecida (São Paulo state, Brazil). Daily measurements of the length of the roots grown from each bulb were carried out throughout the experiment. Mitotic index (MI) and frequency of micronuclei (MN) were determined for 2000 cells per root, using 3-5 root tips from other bulbs (7-10). Only in the roots treated with samples of the River water collected in 2005 in Tremembé city was there a decrease in the root length growth compared to the respective control. However, a reduction in MI values was verified for both sites analysed for that year. Considering the data involving root length growth and especially MI values, a cytotoxic potential is suggested for the water of the River Paraíba do Sul at Tremembé and Aparecida, in the year of 2005. On the other hand, since in this year the MN frequency was not affected with the river water treatments, genotoxicity is not assumed for the river water sampled at the aforementioned places.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física