17 resultados para projection package
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Negative-ion mode electrospray ionization, ESI(-), with Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) was coupled to a Partial Least Squares (PLS) regression and variable selection methods to estimate the total acid number (TAN) of Brazilian crude oil samples. Generally, ESI(-)-FT-ICR mass spectra present a power of resolution of ca. 500,000 and a mass accuracy less than 1 ppm, producing a data matrix containing over 5700 variables per sample. These variables correspond to heteroatom-containing species detected as deprotonated molecules, [M - H](-) ions, which are identified primarily as naphthenic acids, phenols and carbazole analog species. The TAN values for all samples ranged from 0.06 to 3.61 mg of KOH g(-1). To facilitate the spectral interpretation, three methods of variable selection were studied: variable importance in the projection (VIP), interval partial least squares (iPLS) and elimination of uninformative variables (UVE). The UVE method seems to be more appropriate for selecting important variables, reducing the dimension of the variables to 183 and producing a root mean square error of prediction of 0.32 mg of KOH g(-1). By reducing the size of the data, it was possible to relate the selected variables with their corresponding molecular formulas, thus identifying the main chemical species responsible for the TAN values.
Resumo:
This article aimed at comparing the accuracy of linear measurement tools of different commercial software packages. Eight fully edentulous dry mandibles were selected for this study. Incisor, canine, premolar, first molar and second molar regions were selected. Cone beam computed tomography (CBCT) images were obtained with i-CAT Next Generation. Linear bone measurements were performed by one observer on the cross-sectional images using three different software packages: XoranCat®, OnDemand3D® and KDIS3D®, all able to assess DICOM images. In addition, 25% of the sample was reevaluated for the purpose of reproducibility. The mandibles were sectioned to obtain the gold standard for each region. Intraclass coefficients (ICC) were calculated to examine the agreement between the two periods of evaluation; the one-way analysis of variance performed with the post-hoc Dunnett test was used to compare each of the software-derived measurements with the gold standard. The ICC values were excellent for all software packages. The least difference between the software-derived measurements and the gold standard was obtained with the OnDemand3D and KDIS3D (-0.11 and -0.14 mm, respectively), and the greatest, with the XoranCAT (+0.25 mm). However, there was no statistical significant difference between the measurements obtained with the different software packages and the gold standard (p> 0.05). In conclusion, linear bone measurements were not influenced by the software package used to reconstruct the image from CBCT DICOM data.
Resumo:
This research studied the effect of low density polyethylene packaging and storage temperature on the preservation of fresh-cut (minimally processed) cabbage. The cabbages, previously cooled to a temperature of 10 ºC, were selected, washed, cut in four parts (with the central stalk removed), sanitized, cut in strips, rinsed, put in the centrifuge, weighed and stored in plastic packaging of low density polyethylene (70 µm), and then stored in cold chambers at temperatures of 1 and 10 ºC for 20 days. The following aspects were evaluated: carbon dioxide, oxygen and ethylene in the internal atmosphere of the package as well as, pH, titratable acidity, total soluble solids, vitamin C, loss of fresh mass and the total soluble solids/acidity in the fresh-cut cabbage ratio. The experimental design was entirely casual, with three repetitions. The analysis parameters, except for the vitamin C, loss of fresh mass and ethylene, presented significant variation between the temperatures and days of storage. The cabbage stored at a temperature of 1 ºC presented a shelf life of around 15 days, significantly higher than that stored at 10 ºC. At this temperature, on the 8th day of storage, the product was completely decayed, unfit for commercialization or consumption.
Resumo:
The MINUS system was developed as a minimally invasive procedure that uses a diaphyseal cephalic extramedullary implant for the treatment of transtrochanteral fractures of the femur in elderly patients. The implant consists of a sliding screw coupled to a plate adapted to the minimally invasive technique. The surgical access is approximately three centimeters in length located on the lateral surface of the hip, below the projection of the small trochanter. A perfectly adapted instrument was used for the procedure, which also requires the use of an image intensifier, reducing surgery time and rate of bleeding. The objective of this study is to present a new instrument and implant, developed specifically for treatment with the minimally invasive technique, reducing the length of the conventional surgical access from 10 to three centimetres. This new implant was given the commercial name of MINUS System.
Resumo:
In this paper we present a study of reading comprehension based on a contrastive argumentative-discursive approach. We examine the relationship between linguistic materiality and discursive processes, observing the connection between reading in a foreign language, writing production and textual memories in the mother tongue. In addition to an interest in practical language teaching and learning processes (in this case of Spanish and Portuguese), we investigate the question of politeness and the theoretical relationship between subjectivity, language, and textuality. The latter, being understood as the result of discourse regularities, is unique for each and every production, yet is also conditioned by plural discursive memories resulting from contradictory social relationships in a specific historical context (Foucault, 1986; Pêcheux, 1990). In the experiment presented here, we follow some of the procedures of the methodology applied in the European Galatea Project developed for the study of reading strategies in the inter-comprehension between Romance languages (Dabène, 1996). We use the procedure of simulation and the subjective projection of participants as well as the notion of discursive resonance in the analysis. The results, having to do with directness and indirectness in speech and the question of politeness in two typologically close languages, lead to the conclusion that the concept of politeness goes beyond a pragmatic strategy used to avoid conflicts to be approached as a marker of cultural identity constitution. The relevance of discursive awareness and its theoretical and practical consequences are then emphasized.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Fisica
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física