6 resultados para land evaluate system

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the antimicrobial efficacy of Clearfil SE Protect (CP) and Clearfil SE Bond (CB) after curing and rinsed against five individual oral microorganisms as well as a mixture of bacterial culture prepared from the selected test organisms. Bacterial suspensions were prepared from single species of Streptococcus mutans, Streptococcus sobrinus, Streptococcus gordonii, Actinomyces viscosus and Lactobacillus lactis, as well as mixed bacterial suspensions from these organisms. Dentin bonding system discs (6 mm×2 mm) were prepared, cured, washed and placed on the bacterial suspension of single species or multispecies bacteria for 15, 30 and 60 min. MTT, Live/Dead bacterial viability (antibacterial effect), and XTT (metabolic activity) assays were used to test the two dentin system's antibacterial effect. All assays were done in triplicates and each experiment repeated at least three times. Data were submitted to ANOVA and Scheffe's f-test (5%). Greater than 40% bacteria killing was seen within 15 min, and the killing progressed with increasing time of incubation with CP discs. However, a longer (60 min) period of incubation was required by CP to achieve similar antimicrobial effect against mixed bacterial suspension. CB had no significant effect on the viability or metabolic activity of the test microorganisms when compared to the control bacterial culture. CP was significantly effective in reducing the viability and metabolic activity of the test organisms. The results demonstrated the antimicrobial efficacy of CP both on single and multispecies bacterial culture. CP may be beneficial in reducing bacterial infections in cavity preparations in clinical dentistry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper examines the spatial pattern of ill-defined causes of death across Brazilian regions, and its relationship with the evolution of completeness of the deaths registry and changes in the mortality age profile. We make use of the Brazilian Health Informatics Department mortality database and population censuses from 1980 to 2010. We applied demographic methods to evaluate the quality of mortality data for 137 small areas and correct for under-registration of death counts when necessary. The second part of the analysis uses linear regression models to investigate the relationship between, on the one hand, changes in death counts coverage and age profile of mortality, and on the other, changes in the reporting of ill-defined causes of death. The completeness of death counts coverage increases from about 80% in 1980-1991 to over 95% in 2000-2010 at the same time the percentage of ill-defined causes of deaths reduced about 53% in the country. The analysis suggests that the government's efforts to improve data quality are proving successful, and they will allow for a better understanding of the dynamics of health and the mortality transition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Improve the content validity of the instrument for classification of pediatric patients and evaluate its construct validity. A descriptive exploratory study in the measurement of the content validity index, and correlational design for construct validation through exploratory factor analysis. The content validity index for indicators was 0.99 and it was 0.97 for graded situations. Three domains were extracted in the construct validation, namely: patient, family and therapeutic procedures, with 74.97% of explained variance. The instrument showed evidences of content and construct validity. The validation of the instrument occurred under the approach of family-centered care, and allowed incorporating some essential needs of childhood such as playing, interaction and affection in the content of the instrument.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the microtensile bond strength (µTBS) of a fluoride-containing adhesive system submitted to a pH-cycling and storage time regimen for primary outcomes. As secondary outcomes the fluoride released amount was evaluated. Twelve dentin surfaces from sound third molar were divided into 2 groups according to adhesive systems: Clearfil SE Protect (PB) and Clearfil SE Bond (SE). Sticks obtained (1.0 mm2) from teeth were randomly divided into 3 subgroups according to storage regimen model: immediate (24h); 5-month deionized water (W); and pH-cycling model (C). All sticks were tested for µTBS in a universal testing machine. Fluoride concentration was obtained from 1-4 days and 30-day in W and 1-4 days in demineralization (DE)/remineralization (RE) solutions from C, using a fluoride-specific electrode. µTBS and fluoride released data were, respectively, submitted to ANOVA in a split plot design and Tukey, and Friedman' tests (a=0.05). There was no significant interaction between adhesive system and storage regimen for µTBS. W showed the lowest µTBS values. There was no significant difference between 24 h and C models for µTBS. There was no significant difference between adhesive systems. Failure mode was predominantly cohesive within composite for the 24 h and W, for the C group it was mixed for SE and cohesive within composite for PB adhesive system. Fluoride concentrations in the DE/RE solutions were less than 0.03125 ppm and not detected in W. In conclusion, the fluoride-containing adhesive system performed similarly to the regular one. Hydrolytic degradation is the main problem with both adhesive systems, regardless of fluoride contents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To evaluate the distribution of women according to the Robson 10-group classification system (RTGCS) and the occurrence of severe maternal morbidity (SMM) by mode of delivery at a tertiary referral hospital. A retrospective cross-sectional study was conducted of all women admitted to the Women's Hospital at the University of Campinas (Campinas, Brazil) for delivery between January 2009 and July 2013. Women were grouped according to RTGCS. Mode of delivery and SMM (defined as need for admission to the intensive care unit) were assessed. Among 12 771 women, 5957 (46.6%) delivered by cesarean. Overall, 3594 (28.1%) women were in group 1 (nulliparous, single pregnancy, cephalic, term, spontaneous labor), 2328 (18.2%) in group 5 (≥1 previous cesarean, single pregnancy, cephalic, term), and 2112 (16.5%) in group 3 (multiparous excluding previous cesarean, single pregnancy, cephalic, term, spontaneous labor). Group 5 contributed the most cesarean deliveries (1626 [27.3%]), followed by group 2 (nulliparous, single pregnancy, cephalic, term, induced labor or cesarean before labor; 1049 [17.6%]). SMM was more common among women undergoing cesarean delivery than among those delivering vaginally in groups 1-5. The RTGCS allowed the identification of groups with the highest frequency of cesarean delivery and an assessment of SMM. This should be considered in related health policies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m(2) and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index (P = .011) and between the FSS stage and body mass index (P = .012) was found. There was no correlation between age (P = .55) and gender (P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P = .018. In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.