6 resultados para artificial saliva

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the corrosion kinetics and surface topography of Ti-6Al-4V alloy exposed to mouthwash solutions (0.12% chlorhexidine digluconate, 0.053% cetylpyridinium chloride and 3% hydrogen peroxide) compared to artificial saliva (pH6.5) (control). Twenty Ti-6Al-4V alloy disks were used and divided into 4 groups (n=5). For the electrochemical assay, standard tests as open circuit potential and electrochemical impedance spectroscopy (EIS) were applied at baseline, 7 and 14days after immersion in the solutions. Scanning electron microscopy, atomic force microscopy and profilometry (average roughness - Ra) were used for surface characterization. Total weight loss of disks was calculated. Data were analyzed by ANOVA and Bonferroni's test (α=0.05). Hydrogen peroxide generated the lowest polarization resistance (Rp) values for all periods (P<0.05). For the capacitance (Cdl), similar results were observed among groups at baseline (P=0.098). For the 7 and 14-day periods, hydrogen peroxide promoted the highest Cdl values (P<0.0001). Hydrogen peroxide promoted expressive superficial changes and greater Ra values than the others (P<0.0001). It could be concluded that solutions containing cetylpyridinium chloride and chlorhexidine digluconate might be the mouthwashes of choice during the post-operatory period of dental implants. However, hydrogen peroxide is counter-indicated in these situations. Further studies evaluating the dynamics of these solutions (tribocorrosion) and immersing the disks in daily cycles (two or three times a day) to mimic a clinical situation closest to the application of mouthwashes in the oral cavity are warranted to prove our results.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study evaluated the dentine bond strength (BS) and the antibacterial activity (AA) of six adhesives against strict anaerobic and facultative bacteria. Three adhesives containing antibacterial components (Gluma 2Bond (glutaraldehyde)/G2B, Clearfil SE Protect (MDPB)/CSP and Peak Universal Bond (PUB)/chlorhexidine) and the same adhesive versions without antibacterial agents (Gluma Comfort Bond/GCB, Clearfil SE Bond/CSB and Peak LC Bond/PLB) were tested. The AA of adhesives and control groups was evaluated by direct contact method against four strict anaerobic and four facultative bacteria. After incubation, according to the appropriate periods of time for each microorganism, the time to kill microorganisms was measured. For BS, the adhesives were applied according to manufacturers' recommendations and teeth restored with composite. Teeth (n=10) were sectioned to obtain bonded beams specimens, which were tested after artificial saliva storage for one week and one year. BS data were analyzed using two-way ANOVA and Tukey test. Saliva storage for one year reduces the BS only for GCB. In general G2B and GCB required at least 24h for killing microorganisms. PUB and PLB killed only strict anaerobic microorganisms after 24h. For CSP the average time to eliminate the Streptococcus mutans and strict anaerobic oral pathogens was 30min. CSB showed no AA against facultative bacteria, but had AA against some strict anaerobic microorganisms. Storage time had no effect on the BS for most of the adhesives. The time required to kill bacteria depended on the type of adhesive and never was less than 10min. Most of the adhesives showed stable bond strength after one year and the Clearfil SE Protect may be a good alternative in restorative procedures performed on dentine, considering its adequate bond strength and better antibacterial activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Friction coefficient (FC) was quantified between titanium-titanium (Ti-Ti) and titanium-zirconia (Ti-Zr), materials commonly used as abutment and implants, in the presence of a multispecies biofilm (Bf) or salivary pellicle (Pel). Furthermore, FC was used as a parameter to evaluate the biomechanical behavior of a single implant-supported restoration. Interface between Ti-Ti and Ti-Zr without Pel or Bf was used as control (Ctrl). FC was recorded using tribometer and analyzed by two-way Anova and Tukey test (p<0.05). Data were transposed to a finite element model of a dental implant-supported restoration. Models were obtained varying abutment material (Ti and Zr) and FCs recorded (Bf, Pel, and Ctrl). Maximum and shear stress were calculated for bone and equivalent von Misses for prosthetic components. Data were analyzed using two-way ANOVA (p<0.05) and percentage of contribution for each condition (material and FC) was calculated. FC significant differences were observed between Ti-Ti and Ti-Zr for Ctrl and Bf groups, with lower values for Ti-Zr (p<0.05). Within each material group, Ti-Ti differed between all treatments (p<0.05) and for Ti-Zr, only Pel showed higher values compared with Ctrl and Bf (p<0.05). FC contributed to 89.83% (p<0.05) of the stress in the screw, decreasing the stress when the FC was lower. FC resulted in an increase of 59.78% of maximum stress in cortical bone (p=0.05). It can be concluded that the shift of the FC due to the presence of Pel or Bf is able to jeopardize the biomechanical behavior of a single implant-supported restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solar radiation, especially ultraviolet A (UVA) and ultraviolet B (UVB), can cause damage to the human body, and exposure to the radiation may vary according to the geographical location, time of year and other factors. The effects of UVA and UVB radiation on organisms range from erythema formation, through tanning and reduced synthesis of macromolecules such as collagen and elastin, to carcinogenic DNA mutations. Some studies suggest that, in addition to the radiation emitted by the sun, artificial sources of radiation, such as commercial lamps, can also generate small amounts of UVA and UVB radiation. Depending on the source intensity and on the distance from the source, this radiation can be harmful to photosensitive individuals. In healthy subjects, the evidence on the danger of this radiation is still far from conclusive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective Adapt the 6 minutes walking test (6MWT) to artificial gait in complete spinal cord injured (SCI) patients aided by neuromuscular electrical stimulation. Method Nine male individuals with paraplegia (AIS A) participated in this study. Lesion levels varied between T4 and T12 and time post injured from 4 to 13 years. Patients performed 6MWT 1 and 6MWT 2. They used neuromuscular electrical stimulation, and were aided by a walker. The differences between two 6MWT were assessed by using a paired t test. Multiple r-squared was also calculated. Results The 6MWT 1 and 6MWT 2 were not statistically different for heart rate, distance, mean speed and blood pressure. Multiple r-squared (r2 = 0.96) explained 96% of the variation in the distance walked. Conclusion The use of 6MWT in artificial gait towards assessing exercise walking capacity is reproducible and easy to apply. It can be used to assess SCI artificial gait clinical performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the need for artificial tears by glaucoma patients under topical hypotensive treatment and to identify risk factors associated with it. METHODS: The charts of 175 glaucoma patients under medical treatment and 175 age-matched controls were reviewed. Age, gender, use of artificial tears, number of glaucoma medications used, and duration of treatment were recorded. RESULTS: Significantly more glaucoma patients (n=92; 52.6%) used artificial tears compared to age-matched controls (n=31; 17.7%) (p<0.001). Significantly more females (n=81; 39%) than males (n=42; 28.9%) used artificial tears (p=0.036). When the whole population was analyzed, female gender (OR=1.63) and the presence of glaucoma (OR= 5.14) were risk factors for the use of artificial tears (p<0.05). When the glaucoma population was analyzed, female gender (OR=2.57), number of medications >2 (OR=1.92), and duration of treatment >5 years (OR=2.93) were risk factors for the use of artificial tears (p<0.05). CONCLUSIONS: Topical treatment with antiglaucoma medication is a risk factor for the use of artificial tears. Female gender and long-term treatment of glaucoma with two or more medications were aggravating factors for the need for artificial tears.