3 resultados para agitação psicomotora

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report on two epileptic patients who developed acute psychosis after the use of topiramate (TPM). One patient exhibited severe psychomotor agitation, heteroaggressiveness, auditory and visual hallucinations as well as severe paranoid and mystic delusions. The other patient had psychomotor agitation, depersonalization, derealization, severe anxiety and deluded that he was losing his memory. Both patients had to be taken to the casualty room. After interruption of TPM in one patient and reduction of dose in the other, a full remission of the psychotic symptoms was obtained without the need of antipsychotic drugs. Clinicians should be aware of the possibility of development of acute psychotic symptoms in patients undergoing TPM treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The biodegradability of animal wastes production was evaluated through a simplified methodology that allowed the verification of the applicability of anaerobic processes. The experiments were performed in bath reactors, with granular sludge of three origins: UASB reactor treating dairy effluent, UASB reactor treating swine effluent and UASB reactor treating effluent of slaughterhouse of poultry. The experiments (1) - dairy effluent and poultry slaughterhouse non-adapted sludge; (2) -swine effluent and poultry slaughterhouse non-adapted sludge; (3) - dairy effluent and poultry slaughterhouse adapted sludge; (4) - swine effluent and poultry slaughterhouse adapted sludge; (5) - dairy effluent and dairy sludge, and (6) - swine effluent and swine sludge were performed in Incubator Shaker, at a temperature of 35 °C, under agitation at a 150 rpm, for 5 minutes, every 1 hour. A substrat:biomass relationship of 0.5 was used. Kinetic models of Monod, Zero Order, First and Second Order were tested and it was verified that the First Order model provided the best adjustment. The apparent First Order kinetic parameter (k1) was estimated for the experiments 1; 2; 3; 4; 5, and 6, as 2.51 x 10-2; 2.49 x 10-2; 1.90 x 10-2; 3.09 x 10-2; 2.54 x 10-2; 4.09 x 10-2 h-1, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A wild strain of Streptococcus thermophilus isolated from pasteurized milk was evaluated using an experimental model with respect to its adhesion onto stainless steel surfaces and its behaviour when submitted to cleansing and sanification. In milk, the adhesion of the microorganism on to stainless steel surfaces was studied after 6 hours of contact at 45°C with agitation, and after a cleansing process involving cleaning stages with alkaline and acid detergents followed by sanification, in order to evaluate the resistance of the adhered cells. The microorganism adhered to stainless steel surfaces producing a cell load of 10(4) CFU/cm². After alkaline cleansing, no adhered cells were detected but 6 CFU/cm² were still detected on the surfaces after acid cleansing. Cleansing, followed by sanification with sodium hypochlorite, was sufficient to reduce the load of wild S. thermophilus on the stainless steel surfaces to non-detectable levels. The experimental model proved adequate for the study indicating that the wild microorganism S. thermophilus produces biofilms on stainless steel surfaces. Alkaline cleansing remove more that 99.9% of the adhered cells. The few cells adhered on the surface are removed by acid cleansing demonstrating the need to use different steps and types of detergent for efficient cleansing. The best results for the removal of these biofilms are obtained by using alkaline cleansing followed by acid cleaning, this procedure being more efficient when complemented by sanification with sodium hypochlorite.