3 resultados para Water treatment plant residues
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
A fosmid metagenomic library was constructed with total community DNA obtained from a municipal wastewater treatment plant (MWWTP), with the aim of identifying new FeFe-hydrogenase genes encoding the enzymes most important for hydrogen metabolism. The dataset generated by pyrosequencing of a fosmid library was mined to identify environmental gene tags (EGTs) assigned to FeFe-hydrogenase. The majority of EGTs representing FeFe-hydrogenase genes were affiliated with the class Clostridia, suggesting that this group is the main hydrogen producer in the MWWTP analyzed. Based on assembled sequences, three FeFe-hydrogenase genes were predicted based on detection of the L2 motif (MPCxxKxxE) in the encoded gene product, confirming true FeFe-hydrogenase sequences. These sequences were used to design specific primers to detect fosmids encoding FeFe-hydrogenase genes predicted from the dataset. Three identified fosmids were completely sequenced. The cloned genomic fragments within these fosmids are closely related to members of the Spirochaetaceae, Bacteroidales and Firmicutes, and their FeFe-hydrogenase sequences are characterized by the structure type M3, which is common to clostridial enzymes. FeFe-hydrogenase sequences found in this study represent hitherto undetected sequences, indicating the high genetic diversity regarding these enzymes in MWWTP. Results suggest that MWWTP have to be considered as reservoirs for new FeFe-hydrogenase genes.
Resumo:
Current Brazilian law regarding water fluoridation classification is dichotomous with respect to the risks of and benefits for oral diseases, and fluoride (F) concentrations less than 0.6 or above 0.8 mg F/L are considered outside the normal limits. Thus, the law does not consider that both caries and fluorosis are dependent on the dosage and duration of fluoride exposure because they are both chronic diseases. Therefore, this study evaluated the quality of water fluoridation in Maringá, PR, Brazil, considering a new classification for the concentration of F in water the supply, based on the anticaries benefit and risk of fluorosis (CECOL/USP, 2011). Water samples (n = 325) were collected monthly over one year from 28 distribution water networks: 20 from treatment plants and 8 from artesian wells. F concentrations were determined using a specific ion electrode. The average F concentration was 0.77 mg F/L (ppm F), ranging from 0.44 to 1.22 mg F/L. Considering all of the water samples analyzed, 83.7% of them presented from 0.55 to 0.84 mg F/L, and according to the new classification used, they would provide maximum anticaries benefit with a low risk of fluorosis. This percentage was lower (75.4%) in the water samples supplied from artesian wells than from those distributed by the treatment plant (86%). In conclusion, based on the new classification of water F concentrations, the quality of water fluoridation in Maringá is adequate and is within the range of the best balance between risk and benefit.
Resumo:
A novel capillary electrophoresis method using capacitively coupled contactless conductivity detection is proposed for the determination of the biocide tetrakis(hydroxymethyl)phosphonium sulfate. The feasibility of the electrophoretic separation of this biocide was attributed to the formation of an anionic complex between the biocide and borate ions in the background electrolyte. Evidence of this complex formation was provided by (11) B NMR spectroscopy. A linear relationship (R(2) = 0.9990) between the peak area of the complex and the biocide concentration (50-900 μmol/L) was found. The limit of detection and limit of quantification were 15.0 and 50.1 μmol/L, respectively. The proposed method was applied to the determination of tetrakis(hydroxymethyl)phosphonium sulfate in commercial formulations, and the results were in good agreement with those obtained by the standard iodometric titration method. The method was also evaluated for the analysis of tap water and cooling water samples treated with the biocide. The results of the recovery tests at three concentration levels (300, 400, and 600 μmol/L) varied from 75 to 99%, with a relative standard deviation no higher than 9%.