4 resultados para Water Distribution Networks Leak Detection I

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

100.00% 100.00%

Publicador:

Resumo:

As a way to reduce water losses in furrow irrigation systems, used in fresh market tomato production, farmers are improperly distributing water into the field using plastic hose. The objective of this work was to study the suitability of using quick coupler sprinkler as hose connectors for water distribution in tomato plantation. The first step of the study was to assess the current hose field operation for tomato growers. Subsequently, four models of quick couplers sprinklers available in the market were tested in laboratory to determine the coefficient of resistance, the equivalent tube length, the head loss curve and the linking efficiency. As result, a structural design for hose connectors was presented using the model of coupling with the best hydraulic performance. Additionally, some technical recommendations on its use in irrigation water distribution are highlighted. Despite the requirement for additional field trials, the proposed system has potential to optimize the water use efficiency, to improve workers ergonomic conditions, and ensure good profitability to the producer.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Different types of water bodies, including lakes, streams, and coastal marine waters, are often susceptible to fecal contamination from a range of point and nonpoint sources, and have been evaluated using fecal indicator microorganisms. The most commonly used fecal indicator is Escherichia coli, but traditional cultivation methods do not allow discrimination of the source of pollution. The use of triplex PCR offers an approach that is fast and inexpensive, and here enabled the identification of phylogroups. The phylogenetic distribution of E. coli subgroups isolated from water samples revealed higher frequencies of subgroups A1 and B23 in rivers impacted by human pollution sources, while subgroups D1 and D2 were associated with pristine sites, and subgroup B1 with domesticated animal sources, suggesting their use as a first screening for pollution source identification. A simple classification is also proposed based on phylogenetic subgroup distribution using the w-clique metric, enabling differentiation of polluted and unpolluted sites.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel capillary electrophoresis method using capacitively coupled contactless conductivity detection is proposed for the determination of the biocide tetrakis(hydroxymethyl)phosphonium sulfate. The feasibility of the electrophoretic separation of this biocide was attributed to the formation of an anionic complex between the biocide and borate ions in the background electrolyte. Evidence of this complex formation was provided by (11) B NMR spectroscopy. A linear relationship (R(2) = 0.9990) between the peak area of the complex and the biocide concentration (50-900 μmol/L) was found. The limit of detection and limit of quantification were 15.0 and 50.1 μmol/L, respectively. The proposed method was applied to the determination of tetrakis(hydroxymethyl)phosphonium sulfate in commercial formulations, and the results were in good agreement with those obtained by the standard iodometric titration method. The method was also evaluated for the analysis of tap water and cooling water samples treated with the biocide. The results of the recovery tests at three concentration levels (300, 400, and 600 μmol/L) varied from 75 to 99%, with a relative standard deviation no higher than 9%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Current Brazilian law regarding water fluoridation classification is dichotomous with respect to the risks of and benefits for oral diseases, and fluoride (F) concentrations less than 0.6 or above 0.8 mg F/L are considered outside the normal limits. Thus, the law does not consider that both caries and fluorosis are dependent on the dosage and duration of fluoride exposure because they are both chronic diseases. Therefore, this study evaluated the quality of water fluoridation in Maringá, PR, Brazil, considering a new classification for the concentration of F in water the supply, based on the anticaries benefit and risk of fluorosis (CECOL/USP, 2011). Water samples (n = 325) were collected monthly over one year from 28 distribution water networks: 20 from treatment plants and 8 from artesian wells. F concentrations were determined using a specific ion electrode. The average F concentration was 0.77 mg F/L (ppm F), ranging from 0.44 to 1.22 mg F/L. Considering all of the water samples analyzed, 83.7% of them presented from 0.55 to 0.84 mg F/L, and according to the new classification used, they would provide maximum anticaries benefit with a low risk of fluorosis. This percentage was lower (75.4%) in the water samples supplied from artesian wells than from those distributed by the treatment plant (86%). In conclusion, based on the new classification of water F concentrations, the quality of water fluoridation in Maringá is adequate and is within the range of the best balance between risk and benefit.