6 resultados para Válvula Mitral

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

From December-1965 to November-1969, 95 hydrocephalic infants have been operated upon using ventriculoperitoneal shunt with valve (88 cases with a Spitz-Holter valve, 6 cases with a Hakim valve and one case with a Pudenz-Heyer valve). Up to the present time (December, 1970) a total of 54 children are alive with a compensated hydrocephalus and 9 patients died, being impossible to follow-up the 32 remaining cases. The use of the ventriculoperitoneal shunt has eliminated all cardiovascular-pulmonary complications and reduced the number for surgical revisions. Besides, infections involving the draining system are less severe and more easily controlled than those occurring in the ventriculoatrial shunts. After analysis of the surgical techniques as well as complications and results the following conclusions are stated: 1) the use of a valve in the ventriculoperitoneal shunt difficults the oclusion of the peritoneal end of the draining system; 2) good results can be expected without reoperations in about 42,35% of hydrocephalus cases treated by ventriculoperitoneal shunt with valve; 3) ventriculoperitoneal shunts with valve showed better results when compared to ventriculoatrial shunts. This statement is made comparing two groups of hydrocephalic infants submitted to surgery at the same Service and in the same conditions, with the same follow-up period; 4) the cases presented permit to state that at present time the ventriculoperitoneal shunt with valve is the most suitable surgical procedure for hydrocephalus.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study tested whether myocardial extracellular volume (ECV) is increased in patients with hypertension and atrial fibrillation (AF) undergoing pulmonary vein isolation and whether there is an association between ECV and post-procedural recurrence of AF. Hypertension is associated with myocardial fibrosis, an increase in ECV, and AF. Data linking these findings are limited. T1 measurements pre-contrast and post-contrast in a cardiac magnetic resonance (CMR) study provide a method for quantification of ECV. Consecutive patients with hypertension and recurrent AF referred for pulmonary vein isolation underwent a contrast CMR study with measurement of ECV and were followed up prospectively for a median of 18 months. The endpoint of interest was late recurrence of AF. Patients had elevated left ventricular (LV) volumes, LV mass, left atrial volumes, and increased ECV (patients with AF, 0.34 ± 0.03; healthy control patients, 0.29 ± 0.03; p < 0.001). There were positive associations between ECV and left atrial volume (r = 0.46, p < 0.01) and LV mass and a negative association between ECV and diastolic function (early mitral annular relaxation [E'], r = -0.55, p < 0.001). In the best overall multivariable model, ECV was the strongest predictor of the primary outcome of recurrent AF (hazard ratio: 1.29; 95% confidence interval: 1.15 to 1.44; p < 0.0001) and the secondary composite outcome of recurrent AF, heart failure admission, and death (hazard ratio: 1.35; 95% confidence interval: 1.21 to 1.51; p < 0.0001). Each 10% increase in ECV was associated with a 29% increased risk of recurrent AF. In patients with AF and hypertension, expansion of ECV is associated with diastolic function and left atrial remodeling and is a strong independent predictor of recurrent AF post-pulmonary vein isolation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work aimed the development of a low cost servo-valve that answers to an electronic control signal, for variable rates liquid inputs application. A literature research to define which valve type should be used was made. A mechanically activated proportional valve with an electronically controlled servo-engine was designed and evaluated. Since developed the servo-valve, the system was submited to a number of tests .The evaluation of its behavior was obtained in terms of repeatability, hystheresis and linearity. The test was accomplished in a bench, specially developed for this aim. As a result, were obtained three curves of opening percentage as function of flow rate, describing three opening and closing increments in two different work pressures. The servo-valve presented a good repeatability, reasonable hysteresis and a typically quadratic curve. This one maintained the low cost target. These results were very satisfied because the non-linearity and the hysteresis could be easily corrected by software.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física