6 resultados para Symmetry Ratio Algorithm
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Lipidic mixtures present a particular phase change profile highly affected by their unique crystalline structure. However, classical solid-liquid equilibrium (SLE) thermodynamic modeling approaches, which assume the solid phase to be a pure component, sometimes fail in the correct description of the phase behavior. In addition, their inability increases with the complexity of the system. To overcome some of these problems, this study describes a new procedure to depict the SLE of fatty binary mixtures presenting solid solutions, namely the Crystal-T algorithm. Considering the non-ideality of both liquid and solid phases, this algorithm is aimed at the determination of the temperature in which the first and last crystal of the mixture melts. The evaluation is focused on experimental data measured and reported in this work for systems composed of triacylglycerols and fatty alcohols. The liquidus and solidus lines of the SLE phase diagrams were described by using excess Gibbs energy based equations, and the group contribution UNIFAC model for the calculation of the activity coefficients of both liquid and solid phases. Very low deviations of theoretical and experimental data evidenced the strength of the algorithm, contributing to the enlargement of the scope of the SLE modeling.
Resumo:
This study aimed to describe the distribution of waist-to-height ratio (WHtR) percentiles and cutoffs for obesity in Brazilian adolescents. A cross-sectional study including adolescents aged 10 to 15 years was conducted in the city of São Paulo, Brazil; anthropometric measurements (weight, height, and waist-circumference) were taken, and WHtRs were calculated and then divided into percentiles derived by using Least Median of Squares (LMS) regression. The receiver operating characteristic (ROC) curve was used in determining cutoffs for obesity (BMI ≥ 97th percentile) and Mann-Whitney and Kruskal-Wallis tests were used for comparing variables. The study included 8,019 adolescents from 43 schools, of whom 54.5% were female, and 74.8% attended public schools. Boys had higher mean WHtR than girls (0.45 ± 0.06 vs 0.44 ± 0.05; p=0.002) and higher WHtR at the 95th percentile (0.56 vs 0.54; p<0.05). The WHtR cutoffs according to the WHO criteria ranged from 0.467 to 0.506 and 0.463 to 0.496 among girls and boys respectively, with high sensitivity (82.8-95%) and specificity (84-95.5%). The WHtR was significantly associated with body adiposity measured by BMI. Its age-specific percentiles and cutoffs may be used as additional surrogate markers of central obesity and its co-morbidities.
Resumo:
Primary X-ray spectra were measured in the range of 80-150kV in order to validate a computer program based on a semiempirical model. The ratio between the characteristic and total air Kerma was considered to compare computed results and experimental data. Results show that the experimental spectra have higher first HVL and mean energy than the calculated ones. The ratios between the characteristic and total air Kerma for calculated spectra are in good agreement with experimental results for all filtrations used.
Resumo:
Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions. Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high-performance liquid chromatography (HPLC) and high-resolution electrospray ionization mass spectrometry (ESI-(+)-MS) and characterized according to US Pharmacopeia. There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high-resolution ESI-(+)-MS analyses show that brand B contains approximately 2.7 times more hydrolysed cisplatin than brand A. The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high-resolution ESI-(+)-MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.
Resumo:
Annona dioica St. Hil. is a species that grows to approximately 2 m tall and is very widespread in the cerrados. Individual plants of this androdioecious species produce numerous hermaphroditic or male flowers, but few fruits. The aim of this study was to determine the sex ratio among the plants and to compare the frequency of herbivory between male and hermaphroditic flowers. The fieldwork was done by studying flowering plants in grasslands used as pasture for cattle at Fazenda Nhumirim. One hundred and forty-seven male plants and 71 hermaphroditic plants were examined and produced a total of 194 and 94 flowers, respectively, during the study period. The male:hermaphrodite sex ratio was 2.07:1, and was similar to the male:hermaphrodite flower ratio of 2.06:1. The frequency of florivory rate in hermaphrodites was significantly higher than in male flowers (33.0%, n = 31, and 25.7%, n = 50, respectively; G = 14.83; d.f. = 1; p < 0.001). The mean fresh weights of male and hermaphroditic flowers were significantly different (8.38 ± 2.40 g vs. 6.93 ± 2.68 g, respectively; 0 ± SEM; n = 50 each; t = 2.479; d.f. = 49; p = 0.017). These results indicate that the low fruit set in this species can be explained by the sex ratio, the greater herbivory of hermaphroditic flowers and the probable absence of pollinators.
Resumo:
PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.