11 resultados para Surgical implants

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electroacoustic stimulation is an excellent option for people with residual hearing in the low frequencies, who obtain insufficient benefit with hearing aids. To be effective, the subject's residual hearing should be preserved during cochlear implant surgery. To evaluate the hearing preservation in patients that underwent implant placement and to compare the results in accordance with the approach to the inner ear. 19 subjects underwent a soft surgical technique, and the electrode MED-EL FLEX™ EAS, designed to be atraumatic, was used. We evaluated pre- and postoperative tonal audiometric tests with an average of 18.4 months after implantation, to measure the rate of hearing preservation. 17 patients had total or partial preservation of residual hearing; 5 had total hearing preservation and two individuals had no preservation of hearing. The insertion of the electrode occurred through a cochleostomy in 3 patients, and in 2 of these there was no hearing preservation; the other 16 patients experienced electrode insertion through a round window approach. All patients benefited from the cochlear implant, even those who are only using electrical stimulation. The hearing preservation occurred in 89.4% of cases. There was no significant difference between the forms of inner ear approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-acting reversible contraceptives (LARCs) include the copper-releasing intrauterine device (IUD), the levonorgestrel-releasing intrauterine system (LNG-IUS) and implants. Despite the high contraceptive efficacy of LARCs, their prevalence of use remains low in many countries. The objective of this study was to assess the main reasons for switching from contraceptive methods requiring daily or monthly compliance to LARC methods within a Brazilian cohort. Women of 18-50 years of age using different contraceptives and wishing to switch to a LARC method answered a questionnaire regarding their motivations for switching from their current contraceptive. Continuation rates were evaluated 1 year after method initiation. Sample size was calculated at 1040 women. Clinical performance was evaluated by life table analysis. The cutoff date for analysis was May 23, 2013. Overall, 1167 women were interviewed; however, after 1 year of use, the medical records of only 1154 women were available for review. The main personal reason for switching, as reported by the women, was fear of becoming pregnant while the main medical reasons were nausea and vomiting and unscheduled bleeding. No pregnancies occurred during LARC use, and the main reasons for discontinuation were expulsion (in the case of the IUD and LNG-IUS) and a decision to undergo surgical sterilization (in the case of the etonogestrel-releasing implant). Continuation rate was ~95.0/100 women/year for the three methods. Most women chose a LARC method for its safety and for practical reasons, and after 1 year of use, most women continued with the method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Basilar invagination (BI) is a congenital craniocervical junction (CCJ) anomaly represented by a prolapsed spine into the skull-base that can result in severe neurological impairment. In this paper, we retrospective evaluate the surgical treatment of 26 patients surgically treated for symptomatic BI. BI was classified according to instability and neural abnormalities findings. Clinical outcome was evaluated using the Nürick grade system. A total of 26 patients were included in this paper. Their age ranged from 15 to 67 years old (mean 38). Of which, 10 patients were male (38%) and 16 (62%) were female. All patients had some degree of tonsillar herniation, with 25 patients treated with foramen magnum decompression. Nine patients required a craniocervical fixation. Six patients had undergone prior surgery and required a new surgical procedure for progression of neurological symptoms associated with new compression or instability. Most of patients with neurological symptoms secondary to brainstem compression had some improvement during the follow-up. There was mortality in this series, 1 month after surgery, associated with a late removal of the tracheal cannula. Management of BI requires can provide improvements in neurological outcomes, but requires analysis of the neural and bony anatomy of the CCJ, as well as occult instability. The complexity and heterogeneous presentation requires attention to occult instability on examination and attention to airway problems secondary to concomitant facial malformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical site infections (SSIs) can affect body tissues, cavities, or organs manipulated in surgery and constitute 14% to 16% of all infections. This study aimed to determine the incidence of SSIs in women following their discharge from a gynecology outpatient clinic, to survey different types of SSIs among women, and to verify the association of SSIs with comorbidities and clinical conditions. Data were collected via analytical observation with a cross-sectional design, and the study was conducted in 1,026 women who underwent gynecological surgery in a teaching hospital in the municipality of Teresina, in the northeast Brazilian State of Piauí, from June 2011 to March 2013. The incidence of SSIs after discharge was 5.8% among the women in the outpatient clinic. The most prevalent surgery among the patients was hysterectomy, while the most prevalent type of SSI was superficial incisional. Comorbidities in women with SSIs included cancer, diabetes mellitus, and hypertension. Surveillance of SSIs during the post-discharge period is critical for infection prevention and control. It is worth reflecting on the planning of surgical procedures for patients who have risk factors for the development of SSIs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the osseointegration properties of prototyped implants with tridimensionally interconnected pores made of the Ti6Al4V alloy and the influence of a thin calcium phosphate coating. Bilateral critical size calvarial defects were created in thirty Wistar rats and filled with coated and uncoated implants in a randomized fashion. The animals were kept for 15, 45 and 90 days. Implant mechanical integration was evaluated with a push-out test. Bone-implant interface was analyzed using scanning electron microscopy. The maximum force to produce initial displacement of the implants increased during the study period, reaching values around 100N for both types of implants. Intimate contact between bone and implant was present, with progressive bone growth into the pores. No significant differences were seen between coated and uncoated implants. Adequate osseointegration can be achieved in calvarial reconstructions using prototyped Ti6Al4V Implants with the described characteristics of surface and porosity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims to assess the clinical and physiological effects of Roux-en-Y gastric bypass (RYGBP) on type 2 diabetes associated with mild obesity (body mass index [BMI] 30-34.9 kg/m(2)) over 24 months postsurgery. In this prospective trial, 36 mildly obese subjects (19 males) with type 2 diabetes using oral antidiabetic drugs with (n = 24) or without insulin (n = 12) underwent RYGBP. Follow-up was conducted at baseline and 3, 6, 12, and 24 months postsurgery. The following endpoints were considered: changes in HbA1c, fasting glucose and insulin, antidiabetic therapy, BMI, oral glucose insulin sensitivity [OGIS, from meal tolerance test (MTT)], beta-cell secretory function [ΔCP(0-30)/ΔGlu(0-30) (ΔC-peptide/Δglucose ratio, MTT 0-30 min), disposition index (DI = OGIS [Symbol: see text] ΔCP(0-30)/ΔGlu(0-30)], glucagon-like peptide (GLP-1) and glucose-dependent insulinotropic polypeptide (GIP) [incremental area under the curve (AUCi)], adiponectin, C-reactive protein, and lipids. All subjects achieved normal-to-overweight BMI after 3 months. Over 24 months, 31/36 (86 %) subjects presented HbA1c <7 % [complete and partial remission of diabetes in 9/36 (22 %) and 1/36 (3 %), respectively]. Since 3 months postsurgery, improvements were observed in OGIS [290 (174) to 373 (77) ml/min/m(2), P = 0.009], ΔCP(0-30)/ΔGlu(0-30) [0.24 (0.19) to 0.52 (0.34) ng/mg, P = 0.001], DI [7.16 (8.53) to 19.8 (15.4) (ng/mg) (ml/min/m(2)), P = 0.001], GLP-1 AUCi [0.56 (0.64) to 3.97 (3.86) ng/dl [Symbol: see text] 10 min [Symbol: see text] 103, P = 0.000], and GIP AUCi [30.2 (12.6) to 27.0 (20.2) ng/dl [Symbol: see text] 10 min [Symbol: see text] 103, P = 0.004]. At baseline and after 12 months, subjects with diabetes nonremission had longer diabetes duration, higher HbA1c, lower beta-cell secretory function, and higher first 30-min GIP AUCi, compared with those with remission. RYGBP improves the glucose metabolism in subjects with type 2 diabetes and mild obesity. This effect is associated with improvement of insulin sensitivity, beta-cell secretory function, and incretin secretion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Friction coefficient (FC) was quantified between titanium-titanium (Ti-Ti) and titanium-zirconia (Ti-Zr), materials commonly used as abutment and implants, in the presence of a multispecies biofilm (Bf) or salivary pellicle (Pel). Furthermore, FC was used as a parameter to evaluate the biomechanical behavior of a single implant-supported restoration. Interface between Ti-Ti and Ti-Zr without Pel or Bf was used as control (Ctrl). FC was recorded using tribometer and analyzed by two-way Anova and Tukey test (p<0.05). Data were transposed to a finite element model of a dental implant-supported restoration. Models were obtained varying abutment material (Ti and Zr) and FCs recorded (Bf, Pel, and Ctrl). Maximum and shear stress were calculated for bone and equivalent von Misses for prosthetic components. Data were analyzed using two-way ANOVA (p<0.05) and percentage of contribution for each condition (material and FC) was calculated. FC significant differences were observed between Ti-Ti and Ti-Zr for Ctrl and Bf groups, with lower values for Ti-Zr (p<0.05). Within each material group, Ti-Ti differed between all treatments (p<0.05) and for Ti-Zr, only Pel showed higher values compared with Ctrl and Bf (p<0.05). FC contributed to 89.83% (p<0.05) of the stress in the screw, decreasing the stress when the FC was lower. FC resulted in an increase of 59.78% of maximum stress in cortical bone (p=0.05). It can be concluded that the shift of the FC due to the presence of Pel or Bf is able to jeopardize the biomechanical behavior of a single implant-supported restoration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate pathologic features with implications on surgical radicality in women treated with radical hysterectomy and pelvic lymphadenectomy for cervical cancer stage IA1 with lymph vascular space invasion (LVSI) and stage IA2 by correlating findings in conization and hysterectomy specimens. Women with cervical cancer stage IA1 with LVSI and stage IA2 diagnosed by loop electrosurgical excisional procedure or cold knife conization were treated with radical hysterectomy and pelvic lymphadenectomy from January 1999 to December 2011 in 2 institutions. Fifty patients were enrolled: 40 with stage IA2 and 10 with stage IA1 with LVSI. Median age was 43 (30-67) years. All patients underwent cervical conization for diagnosis (45 loop electrosurgical excisional procedure, 5 cold knife). Lymph vascular space invasion was detected in 15 patients (30%). Two patients had positive pelvic nodes. No parametrial involvement was detected in the entire cohort. Positive margins were present in 35 patients, and residual disease was detected in 22 patients (44%). Positive margins predicted residual disease at radical hysterectomy (P = 0.02). Medium follow-up time was 51 months. One patient developed a pelvic recurrence, and there were no disease-related deaths. Patients with positive margins in cone biopsy specimens have an increased risk of residual disease at radical hysterectomy and require careful evaluation before conservative surgery. Pelvic lymph node evaluation is essential because lymph node metastasis may occur even in early stages. The lack of parametrial invasion in this study reinforces the knowledge that the select group of patients with microinvasive cervical carcinoma stages IA1 LVSI and stage IA2 have a very low risk of parametrial infiltration. Less radical surgery can be carefully considered for these patients.