4 resultados para SAMPLE INJECTION

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to report the outcome of a patient who developed compartment syndrome after South American rattlesnake (Crotalus durissus terrificus) envenomation, confirmed by subfascial pressure measurement and magnetic resonance imaging (MRI). A 63-year-old male was admitted 1 h after being bitten on the right elbow by a large snake, which was not brought for identification. Physical and laboratory features upon admission revealed two fang marks, local tense swelling, paresthesia, intense local pain, hypertension, coagulopathy, and CK = 1530 U/L (RV < 170 U/L). The case was initially treated with bothropic antivenom (80 mL, intravenously), with no improvement. Evolution within 13-14 h post-bite revealed generalized myalgia, muscle weakness, palpebral ptosis, and severe rhabdomyolysis (CK = 126,160 U/L) compatible with envenoming by C. d. terrificus. The patient was then treated with crotalic antivenom (200 mL, intravenously), fluid replacement, and urine alkalinization. Twenty-four-hour post-bite MRI showed marked muscular edema in the anterior compartment of the right forearm, with a high subfascial pressure (40 mmHg) being detected 1 h later. ELISA of a blood sample obtained upon admission, before antivenom infusion, revealed a high serum concentration of C. d. terrificus venom. No fasciotomy was performed and the patient was discharged seven days later without sequelae. Snakebite by C. d. terrificus with subfascial venom injection may lead to increased intracompartmental pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current data indicate that the size of high-density lipoprotein (HDL) may be considered an important marker for cardiovascular disease risk. We established reference values of mean HDL size and volume in an asymptomatic representative Brazilian population sample (n=590) and their associations with metabolic parameters by gender. Size and volume were determined in HDL isolated from plasma by polyethyleneglycol precipitation of apoB-containing lipoproteins and measured using the dynamic light scattering (DLS) technique. Although the gender and age distributions agreed with other studies, the mean HDL size reference value was slightly lower than in some other populations. Both HDL size and volume were influenced by gender and varied according to age. HDL size was associated with age and HDL-C (total population); non- white ethnicity and CETP inversely (females); HDL-C and PLTP mass (males). On the other hand, HDL volume was determined only by HDL-C (total population and in both genders) and by PLTP mass (males). The reference values for mean HDL size and volume using the DLS technique were established in an asymptomatic and representative Brazilian population sample, as well as their related metabolic factors. HDL-C was a major determinant of HDL size and volume, which were differently modulated in females and in males.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow injection method for the quantitative analysis of ketoconazole in tablets, based on the reaction with iron (III) ions, is presented. Ketoconazole forms a red complex with iron ions in an acid medium, with maximum absorbance at 495 nm. The detection limit was estimated to be 1×10--4 mol L-1; the quantitation limit is about 3×10--4 mol L-1 and approximately 30 determinations can be performed in an hour. The results were compared with those obtained with a reference HPLC method. Statistical comparisons were done using the Student's t procedure and the F test. Complete agreement was found at the 0.95 significance level between the proposed flow injection and the HPLC procedures. The two methods present similar precision, i.e., for HPLC the mean relative standard deviation was ca. 1.2% and for FIA ca. 1.6%.