9 resultados para Refractive index sensor

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This chapter provides a short review of quantum dots (QDs) physics, applications, and perspectives. The main advantage of QDs over bulk semiconductors is the fact that the size became a control parameter to tailor the optical properties of new materials. Size changes the confinement energy which alters the optical properties of the material, such as absorption, refractive index, and emission bands. Therefore, by using QDs one can make several kinds of optical devices. One of these devices transforms electrons into photons to apply them as active optical components in illumination and displays. Other devices enable the transformation of photons into electrons to produce QDs solar cells or photodetectors. At the biomedical interface, the application of QDs, which is the most important aspect in this book, is based on fluorescence, which essentially transforms photons into photons of different wavelengths. This chapter introduces important parameters for QDs' biophotonic applications such as photostability, excitation and emission profiles, and quantum efficiency. We also present the perspectives for the use of QDs in fluorescence lifetime imaging (FLIM) and Förster resonance energy transfer (FRET), so useful in modern microscopy, and how to take advantage of the usually unwanted blinking effect to perform super-resolution microscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bariatric surgery is considered an effective method for sustained weight loss, but may cause various nutritional complications. The aim of this study was to evaluate the nutritional status of minerals and vitamins, food consumption, and to monitor physiologic parameters in patients with obesity before and 6 months after Roux-en-Y gastric bypass surgery (RYGB). Thirty-six patients who had undergone RYGB were prospectively evaluated before and 6 months after surgery. At each phase their weight, height, body mass index (BMI), Electro Sensor Complex (ES Complex) data, food consumption, and total protein serum levels, albumin, prealbumin, parathyroid hormone (PTH), zinc (Zn), B12 vitamin (VitB12), iron (Fe), ferritin, copper (Cu), ionic calcium (CaI), magnesium (Mg), and folic acid were assessed. The mean weight loss from baseline to 6 months after surgery was 35.34±4.82%. Markers of autonomic nervous system balance (P<.01), stiffness index (P<.01), standard deviation of normal-to-normal R-R intervals (SDNN) (P<.01), and insulin resistance (P<.001) were also improved. With regard to the micronutrients measured, 34 patients demonstrated some kind of deficiency. There was a high percentage of Zn deficiency in both pre- (55.55%) and postoperative (61.11%) patients, and 33.33% of the patients were deficient in prealbumin postoperatively. The protein intake after 6 months of surgery was below the recommended intake (<70 g/d) for 88.88% of the patients. Laboratory analyses demonstrated an average decrease in total protein (P<.05), prealbumin (P = .002), and PTH (P = .008) between pre- and postsurgery, and a decrease in the percentage of deficiencies for Mg (P<.05), CaI (P<.05), and Fe (P = .021). Despite improvements in the autonomic nervous system balance, stiffness index markers and insulin resistance, we found a high prevalence of hypozincemia at 6 months post-RYGB. Furthermore, protein supplements were needed to maintain an adequate protein intake up to 6 months postsurgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

77

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze the relationship between parity, pre-pregnancy body mass index (BMI), and gestational weight gain (GWG). This observational controlled study was conducted from November 2013 to April 2014, with postpartum women who started antenatal care up to 14 weeks and had full-term births. Data were collected from medical records and antenatal cards. Descriptive and bivariate analyses were performed. The significance level was 5%. Data were collected from 130 primiparous and 160 multiparous women. At the beginning of prenatal care, 54.62% of the primiparous were eutrophic, while the majority of multiparous were overweight or obese (62.51%). Multiparas are two times more likely to be obese at the beginning of their pregnancies, when compared to primiparas. The average pre-pregnancy weight and final pregnancy weight was significantly higher in multiparous, however, the mean GWG was higher among primiparous. We found an inverse correlation between parity and the total GWG, but initial BMI was significantly higher in multiparas. Nevertheless, monitoring of the GWG through actions that promote a healthier lifestyle is needed, regardless of parity and nutritional status, in order to prevent excessive GWG and postpartum weight retention and consequently inadequate pre-pregnancy nutritional status in future pregnancies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nutrients composition, phenolic compounds, antioxidant activity and estimated glycemic index (EGI) were evaluated in sorghum bran (SB) and decorticated sorghum flour (DSF), obtained by a rice-polisher, as well as whole sorghum flour (WSF). Correlation between EGI and the studied parameters were determined. SB presented the highest protein, lipid, ash, β-glucan, total and insoluble dietary fiber contents; and the lowest non-resistant and total starch contents. The highest carbohydrate and resistant starch contents were in DSF and WSF, respectively. Phenolic compounds and antioxidant activities were concentrated in SB. The EGI values were: DSF 84.5±0.41; WSF 77.2±0.33; and SB 60.3±0.78. Phenolic compounds, specific flavonoids and antioxidant activities, as well as total, insoluble and soluble dietary fiber and β-glucans of sorghum flour samples were all negatively correlated to EGI. RS content was not correlated to EGI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this work was to compare the soybean crop mapping in the western of Parana State by MODIS/Terra and TM/Landsat 5 images. Firstly, it was generated a soybean crop mask using six TM images covering the crop season, which was used as a reference. The images were submitted to Parallelepiped and Maximum Likelihood digital classification algorithms, followed by visual inspection. Four MODIS images, covering the vegetative peak, were classified using the Parallelepiped method. The quality assessment of MODIS and TM classification was carried out through an Error Matrix, considering 100 sample points between soybean or not soybean, randomly allocated in each of the eight municipalities within the study area. The results showed that both the Overall Classification (OC) and the Kappa Index (KI) have produced values ranging from 0.55 to 0.80, considered good to very good performances, either in TM or MODIS images. When OC and KI, from both sensors were compared, it wasn't found no statistical difference between them. The soybean mapping, using MODIS, has produced 70% of reliance in terms of users. The main conclusion is that the mapping of soybean by MODIS is feasible, with the advantage to have better temporal resolution than Landsat, and to be available on the internet, free of charge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To establish the prevalence of refractive errors and ocular disorders in preschool and schoolchildren of Ibiporã, Brazil. Methods: A survey of 6 to 12-year-old children from public and private elementary schools was carried out in Ibiporã between 1989 and 1996. Visual acuity measurements were performed by trained teachers using Snellen's chart. Children with visual acuity <0.7 in at least one eye were referred to a complete ophthalmologic examination. Results: 35,936 visual acuity measurements were performed in 13,471 children. 1.966 children (14.59%) were referred to an ophthalmologic examination. Amblyopia was diagnosed in 237 children (1.76%), whereas strabismus was observed in 114 cases (0.84%). Cataract (n=17) (0.12%), chorioretinitis (n=38) (0.28%) and eyelid ptosis (n=6) (0.04%) were also diagnosed. Among the 614 (4.55%) children who were found to have refractive errors, 284 (46.25%) had hyperopia (hyperopia or hyperopic astigmatism), 206 (33.55%) had myopia (myopia or myopic astigmatism) and 124 (20.19%) showed mixed astigmatism. Conclusions: The study determined the local prevalence of amblyopia, refractive errors and eye disorders among preschool and schoolchildren.