4 resultados para Ordem SV(O) e VS

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física