19 resultados para Norbert Elias.

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Button battery ingestion is a frequent pediatric complaint. The serious complications resulting from accidental ingestion have increased significantly over the last two decades due to easy access to gadgets and electronic toys. Over recent years, the increasing use of lithium batteries of diameter 20 mm has brought new challenges, because these are more detrimental to the mucosa, compared with other types, with high morbidity and mortality. The clinical complaints, which are often nonspecific, may lead to delayed diagnosis, thereby increasing the risk of severe complications. A five-year-old boy who had been complaining of abdominal pain for ten days, was brought to the emergency service with a clinical condition of hematemesis that started two hours earlier. On admission, he presented pallor, tachycardia and hypotension. A plain abdominal x-ray produced an image suggestive of a button battery. Digestive endoscopy showed a deep ulcerated lesion in the esophagus without active bleeding. After this procedure, the patient presented profuse hematemesis and severe hypotension, followed by cardiorespiratory arrest, which was reversed. He then underwent emergency exploratory laparotomy and presented a new episode of cardiorespiratory arrest, which he did not survive. The battery was removed through rectal exploration. This case describes a fatal evolution of button battery ingestion with late diagnosis and severe associated injury of the digestive mucosa. A high level of clinical suspicion is essential for preventing this evolution. Preventive strategies are required, as well as health education, with warnings to parents, caregivers and healthcare professionals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate central auditory processing in children with unilateral stroke and to verify whether the hemisphere affected by the lesion influenced auditory competence. 23 children (13 male) between 7 and 16 years old were evaluated through speech-in-noise tests (auditory closure); dichotic digit test and staggered spondaic word test (selective attention); pitch pattern and duration pattern sequence tests (temporal processing) and their results were compared with control children. Auditory competence was established according to the performance in auditory analysis ability. Was verified similar performance between groups in auditory closure ability and pronounced deficits in selective attention and temporal processing abilities. Most children with stroke showed an impaired auditory ability in a moderate degree. Children with stroke showed deficits in auditory processing and the degree of impairment was not related to the hemisphere affected by the lesion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of screening techniques, such as an alternative light source (ALS), is important for finding biological evidence at a crime scene. The objective of this study was to evaluate whether biological fluid (blood, semen, saliva, and urine) deposited on different surfaces changes as a function of the age of the sample. Stains were illuminated with a Megamaxx™ ALS System and photographed with a Canon EOS Utility™ camera. Adobe Photoshop™ was utilized to prepare photographs for analysis, and then ImageJ™ was used to record the brightness values of pixels in the images. Data were submitted to analysis of variance using a generalized linear mixed model with two fixed effects (surface and fluid). Time was treated as a random effect (through repeated measures) with a first-order autoregressive covariance structure. Means of significant effects were compared by the Tukey test. The fluorescence of the analyzed biological material varied depending on the age of the sample. Fluorescence was lower when the samples were moist. Fluorescence remained constant when the sample was dry, up to the maximum period analyzed (60 days), independent of the substrate on which the fluid was deposited, showing the novelty of this study. Therefore, the forensic expert can detect biological fluids at the crime scene using an ALS even several days after a crime has occurred.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This postdoctoral study on the application of the RIME intervention in women that had undergone mastectomy and were in treatment, aimed to promote psychospiritual and social transformations to improve the quality of life, self-esteem and hope. A total of 28 women participated and were randomized into two groups. Brief Psychotherapy (PB) (average of six sessions) was administered in the Control Group, and RIME (three sessions) and BP (average of five sessions) were applied in the RIME Group. The quantitative results indicated a significant improvement (38.3%) in the Perception of Quality of Life after RIME according to the WHOQOL, compared both to the BP of the Control Group (12.5%), and the BP of the RIME Group (16.2%). There was a significant improvement in Self-esteem (Rosenberg) after RIME (14.6%) compared to the BP of the Control Group (worsened 35.9%), and the BP of the RIME Group (8.3%). The improvement in well-being, considering the focus worked on (Visual Analog Scale), was significant in the RIME Group (bad to good), as well as in the Control Group (unpleasant to good). The qualitative results indicated that RIME promotes creative transformations in the intrapsychic and interpersonal dimensions, so that new meanings and/or new attitudes emerge into the consciousness. It was observed that RIME has more strength of psychic structure, ego strengthening and provides a faster transformation that BP, therefore it can be indicated for crisis treatment in the hospital environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mechanically evoked reflexes have been postulated to be less sensitive to presynaptic inhibition (PSI) than the H-reflex. This has implications on investigations of spinal cord neurophysiology that are based on the T-reflex. Preceding studies have shown an enhanced effect of PSI on the H-reflex when a train of ~10 conditioning stimuli at 1 Hz was applied to the nerve of the antagonist muscle. The main questions to be addressed in the present study are if indeed T-reflexes are less sensitive to PSI and whether (and to what extent and by what possible mechanisms) the effect of low frequency conditioning, found previously for the H-reflex, can be reproduced on T-reflexes from the soleus muscle. We explored two different conditioning-to-test (C-T) intervals: 15 and 100 ms (corresponding to D1 and D2 inhibitions, respectively). Test stimuli consisted of either electrical pulses applied to the posterior tibial nerve to elicit H-reflexes or mechanical percussion to the Achilles tendon to elicit T-reflexes. The 1 Hz train of conditioning electrical stimuli delivered to the common peroneal nerve induced a stronger effect of PSI as compared to a single conditioning pulse, for both reflexes (T and H), regardless of C-T-intervals. Moreover, the conditioning train of pulses (with respect to a single conditioning pulse) was proportionally more effective for T-reflexes as compared to H-reflexes (irrespective of the C-T interval), which might be associated with the differential contingent of Ia afferents activated by mechanical and electrical test stimuli. A conceivable explanation for the enhanced PSI effect in response to a train of stimuli is the occurrence of homosynaptic depression at synapses on inhibitory interneurons interposed within the PSI pathway. The present results add to the discussion of the sensitivity of the stretch reflex pathway to PSI and its functional role.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the occurrence of severe obstetric complications associated with antepartum and intrapartum hemorrhage among women from the Brazilian Network for Surveillance of Severe Maternal Morbidity. Multicenter cross-sectional study. Twenty-seven obstetric referral units in Brazil between July 2009 and June 2010. A total of 9555 women categorized as having obstetric complications. The occurrence of potentially life-threatening conditions, maternal near miss and maternal deaths associated with antepartum and intrapartum hemorrhage was evaluated. Sociodemographic and obstetric characteristics and the use of criteria for management of severe bleeding were also assessed in these women. The prevalence ratios with their respective 95% confidence intervals adjusted for the cluster effect of the design, and multiple logistic regression analysis were performed to identify factors independently associated with the occurrence of severe maternal outcome. Antepartum and intrapartum hemorrhage occurred in only 8% (767) of women experiencing any type of obstetric complication. However, it was responsible for 18.2% (140) of maternal near miss and 10% (14) of maternal death cases. On multivariate analysis, maternal age and previous cesarean section were shown to be independently associated with an increased risk of severe maternal outcome (near miss or death). Severe maternal outcome due to antepartum and intrapartum hemorrhage was highly prevalent among Brazilian women. Certain risk factors, maternal age and previous cesarean delivery in particular, were associated with the occurrence of bleeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To assess the occurrence of severe maternal complications owing to postpartum hemorrhage (PPH) and its associated factors. A secondary analysis of data from a multicenter cross-sectional prospective surveillance study included 9555 cases of severe maternal morbidity at 27 centers in Brazil between July 2009 and June 2010. Complications of PPH, conditions of severity management, and sociodemographic and obstetric characteristics were assessed. Factors independently associated with severe maternal outcome (SMO) were identified using multiple regression analysis. Overall, 1192 (12.5%) of the 9555 women experienced complications owing to PPH (981 had potentially life-threatening conditions, 181 maternal near miss, and 30 had died). The SMO ratio was 2.6 per 1000 live births among women with PPH and 8.5 per 1000 live births among women with other complications. Women with PPH had a higher risk of blood transfusion and return to the operating theater than did those with complications from other causes. Maternal age, length of pregnancy, previous uterine scar, and cesarean delivery were the main factors associated with an increased risk of SMO secondary to PPH. PPH frequently leads to severe maternal morbidity. A surveillance system can identify the main causes of morbidity and could help to improve care, especially among women identified as being at high risk of PPH.