3 resultados para Minimum Spouting Velocity
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
The spouted and fluidized bed technologies are usually employed in operations of drying, coating and granulation of particles by the chemical and pharmaceutical industries. The use of these techniques in agronomy is limited to the treatment of some species of seeds. In this work, the objective was to analyse the fluid-dynamics of fluidized and spouted beds when broccoli (Brassica oleracea L. var. Italica) seeds are used and also to verify the influence on seed germination after 60 min of seed exposition to spouting or fluidization, at room temperature. The fluid-dynamics was defined by the measurements of the bed pressure drop as a function of the air flow rate for different seeds loads. The experimental conditions were based on the physical properties of the seeds and were limited by the apparatus dimensions. The cone-cylindrical bed was constructed in plexyglass to permit flow visualization. The values of the parameters: maximum pressure drop, minimum spouting flow rate and pressure drop, and stable spout pressure drop were experimentally obtained from the fluid-dynamic analysis and were compared with the values calculated by empirical equations found in the literature. The same procedure was carried out with the fluidized bed and the important parameters for this regime were the air velocity and the bed pressure drop at minimum fluidization. The analysis of seed germination indicated that no damage was caused to the seeds by the spout or fluidization processes.
Resumo:
Application of mechanical vibration to aid fluidization and to improve heat, mass and momentum transfer are usual processes in agricultural industry and it has found nowadays extensive applications in particle processing of materials difficult-to-fluidized. Equations and experimental data found in literature for the aerodynamics characteristics of vibro-fluidized beds are presented and discussed, emphasizing the vibration effect in the bed.
Resumo:
OBJECTIVE: To adapted the critical velocity (CV), RAST test and lactate minimum (LM) to evaluation of female basketball players. METHODS: Twelve well-trained female basketball players (19 ± 1yrs) were submitted to four intensities running (10 - 14 km/h) at shuttle exercise until exhaustion, applied on alternate days. The linear model 'velocity vs. 1/tlim' was adopted to determine the aerobic (CV) and anaerobic (CCA) parameters. The lactate minimum test consisted of two phases: 1) hiperlactatemia induction using the RAST test and 2) incremental test composed by five shuttle run (20-m) at 7, 8, 9, 10, and 12 km/h. Blood samples were collected at the end of each stage. RESULTS: The velocity (vLM) and blood lactate concentration at LM were obtained by two polynomial adjustments: lactate vs. intensity (LM1) and lactate vs. time (LM2). ANOVA one-way, Student t-test and Pearson correlation were used for statistical analysis. The CV was obtained at 10.3 ± 0.2 km/h and the CCA estimated at 73.0 ± 3.4 m. The RAST was capable to induce the hiperlactatemia and to determine the Pmax (3.6 ± 0.2 W/kg), Pmed (2.8 ± 0.1 W/kg), Pmin (2.3 ± 0.1 W/kg) and FI (30 ± 3%). The vLM1 and vLM2 were obtained, respectively, at 9.47 ±0.13 km/h and 9.8 ± 0.13 km/h, and CV was higher than vLM1. CONCLUSION: The results suggest that the non-invasive model can be used to determine the aerobic and anaerobic parameters. Furthermore, the LM test adapted to basketball using RAST and progressive phase was effective to evaluate female athletes considering the specificity of modality, with high success rates observed in polynomial adjustment 'lactate vs. time' (LM2).