12 resultados para Maxillofacial prostheses
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Harmony is one of the main objectives in surgical and orthodontic treatment and this harmony must be present in the smile, as well as in the face. The aim of the present study was to assess the perceptions of professionals and laypersons in relation to the harmony of the smile of patients with or without vertical maxillary alterations. Sixty observers (oral and maxillofacial surgeons, orthodontists and laypersons) reported the degree of harmony of six smiles using an objective questionnaire and the participants indicated if there was a need for corrective surgery or not. The classification of observers was recorded on a Likert scale from 1 to 5. Mixed regression was used to determine differences between the three groups. Statistically significant differences were found only for the harmony of the smile between the oral and maxillofacial surgeons and laypersons, with laypersons being more critical when assessing the smile. There was no statistical difference between the other groups for the harmony of the smile or the indication of corrective surgery. The patterns of greater or lesser harmony determined by observers during the smile were similar to those found in the literature as the ideal standard in relation to vertical maxillary positioning. Laypersons had a tendency to be more critical in relation to facial harmony than surgeons, although no statistical differences were found in the other groups in relation to the harmony of the smile or indication for the corrective surgery. In addition, the patterns of greater or lesser harmony of the smile determined by the participants were similar to those found in the literature as the ideal standard in relation to vertical maxillary positioning. Overall, the present study demonstrates that adequate interaction between surgeons, orthodontists and laypersons is essential in order to achieve facial harmony with orthodontic and/or surgical treatment. Opinion of specialists and laypersons about the smile in relation to the vertical positioning of the maxilla.
Resumo:
Bisphosphonates (BPs) are a class of drugs used to treat osteoporosis and malignant bone metastasis. BPs show high binding capacity to the bone matrix, especially in sites of active bone metabolism. The American Society for Bone and Mineral Research defines BRONJ as an area of exposed bone in the maxillofacial region that has not healed within 8 weeks after identification by a healthcare provider in a patient who is receiving or has been exposed to a bisphosphonate and has not had radiation therapy to the craniofacial region. Bisphosphonate-related osteonecrosis of the jaw (BRONJ) can adversely affect quality of life, as it may produce significant morbidity. The American Association of Oral and Maxillofacial Surgeons (AAOMS) considers as vitally important that information on BRONJ be disseminated to other dental and medical specialties. The purpose of this work is to offer a perspective on how dentists should manage patients on BPs, to show the benefits of accurately diagnosing BRONJ, and to present diagnostic aids and treatments strategies for the condition.
Resumo:
The aim of this study was to evaluate by photoelastic analysis stress distribution on short and long implants of two dental implant systems with 2-unit implant-supported fixed partial prostheses of 8 mm and 13 mm heights. Sixteen photoelastic models were divided into 4 groups: I: long implant (5 × 11 mm) (Neodent), II: long implant (5 × 11 mm) (Bicon), III: short implant (5 × 6 mm) (Neodent), and IV: short implants (5 × 6 mm) (Bicon). The models were positioned in a circular polariscope associated with a cell load and static axial (0.5 Kgf) and nonaxial load (15°, 0.5 Kgf) were applied to each group for both prosthetic crown heights. Three-way ANOVA was used to compare the factors implant length, crown height, and implant system (α = 0.05). The results showed that implant length was a statistically significant factor for both axial and nonaxial loading. The 13 mm prosthetic crown did not result in statistically significant differences in stress distribution between the implant systems and implant lengths studied, regardless of load type (P > 0.05). It can be concluded that short implants showed higher stress levels than long implants. Implant system and length was not relevant factors when prosthetic crown height were increased.
Resumo:
Abstract The aim of this study was to evaluate three transfer techniques used to obtain working casts of implant-supported prostheses through the marginal misfit and strain induced to metallic framework. Thirty working casts were obtained from a metallic master cast, each one containing two implant analogues simulating a clinical situation of three-unit implant-supported fixed prostheses, according to the following transfer impression techniques: Group A, squared transfers splinted with dental floss and acrylic resin, sectioned and re-splinted; Group B, squared transfers splinted with dental floss and bis-acrylic resin; and Group N, squared transfers not splinted. A metallic framework was made for marginal misfit and strain measurements from the metallic master cast. The misfit between metallic framework and the working casts was evaluated with an optical microscope following the single-screw test protocol. In the same conditions, the strain was evaluated using strain gauges placed on the metallic framework. The data was submitted to one-way ANOVA followed by the Tukey's test (α=5%). For both marginal misfit and strain, there were statistically significant differences between Groups A and N (p<0.01) and Groups B and N (p<0.01), with greater values for the Group N. According to the Pearson's test, there was a positive correlation between the variables misfit and strain (r=0.5642). The results of this study showed that the impression techniques with splinted transfers promoted better accuracy than non-splinted one, regardless of the splinting material utilized.
Resumo:
A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.
Resumo:
This study involved a retrospective evaluation of patients subjected to surgery for dentofacial deformities treated without induced controlled hypotension (group I, n=50) and a prospective evaluation of patients who were subjected to surgery under hypotensive general anaesthesia (group II, n=50). No statistical differences were found between the study groups with regard to the duration of surgery. However, there were statistically significant differences in the need for blood transfusion and the occurrence of bradycardia during the maxillary down-fracture. Hypotensive anaesthesia decreased the need for a blood transfusion and the occurrence of bradycardia, and is therefore considered highly beneficial for patients undergoing orthognathic surgery.
Resumo:
The aim of this retrospective study was to compare the peculiarities of maxillofacial injuries caused by interpersonal violence with other etiologic factors. Medical records of 3,724 patients with maxillofacial injuries in São Paulo state (Brazil) were retrospectively analyzed. The data were submitted to statistical analysis (simple descriptive statistics and Chi-squared test) using SPSS 18.0 software. Data of 612 patients with facial injuries caused by violence were analyzed. The majority of the patients were male (81%; n = 496), with a mean age of 31.28 years (standard deviation of 13.33 years). These patients were more affected by mandibular and nose fractures, when compared with all other patients (P < 0.01), although fewer injuries were recorded in other body parts (χ(2) = 17.54; P < 0.01); Victims of interpersonal violence exhibited more injuries when the neurocranium was analyzed in isolation (χ(2) = 6.85; P < 0.01). Facial trauma due to interpersonal violence seem to be related to a higher rate of facial fractures and lacerations when compared to all patients with facial injuries. Prominent areas of the face and neurocranium were more affected by injuries.
Resumo:
Maxillofacial trauma resulting from falls in elderly patients is a major social and health care concern. Most of these traumatic events involve mandibular fractures. The aim of this study was to analyze stress distributions from traumatic loads applied on the symphyseal, parasymphyseal, and mandibular body regions in the elderly edentulous mandible using finite-element analysis (FEA). Computerized tomographic analysis of an edentulous macerated human mandible of a patient approximately 65 years old was performed. The bone structure was converted into a 3-dimensional stereolithographic model, which was used to construct the computer-aided design (CAD) geometry for FEA. The mechanical properties of cortical and cancellous bone were characterized as isotropic and elastic structures, respectively, in the CAD model. The condyles were constrained to prevent free movement in the x-, y-, and z-axes during simulation. This enabled the simulation to include the presence of masticatory muscles during trauma. Three different simulations were performed. Loads of 700 N were applied perpendicular to the surface of the cortical bone in the symphyseal, parasymphyseal, and mandibular body regions. The simulation results were evaluated according to equivalent von Mises stress distributions. Traumatic load at the symphyseal region generated low stress levels in the mental region and high stress levels in the mandibular neck. Traumatic load at the parasymphyseal region concentrated the resulting stress close to the mental foramen. Traumatic load in the mandibular body generated extensive stress in the mandibular body, angle, and ramus. FEA enabled precise mapping of the stress distribution in a human elderly edentulous mandible (neck and mandibular angle) in response to 3 different traumatic load conditions. This knowledge can help guide emergency responders as they evaluate patients after a traumatic event.
Resumo:
The aim of this study was to evaluate the microscopic structure and chemical composition of titanium bone plates and screws retrieved from patients with a clinical indication and to relate the results to the clinical conditions associated with the removal of these devices. Osteosynthesis plates and screws retrieved from 30 patients between January 2010 and September 2013 were studied by metallographic, gas, and energy dispersive X-ray (EDX) analyses and the medical records of these patients were reviewed. Forty-eight plates and 238 screws were retrieved. The time elapsed between plate and screw insertion and removal ranged between 11 days and 10 years. Metallographic analysis revealed that all the plates were manufactured from commercially pure titanium (CP-Ti). The screw samples analyzed consisted of Ti-6Al-4V alloy, except four samples, which consisted of CP-Ti. Titanium plates studied by EDX analysis presented greater than 99.7% titanium by mass. On gas analysis of Ti-6Al-4V screws, three samples were outside the standard values. One CP-Ti screw sample and one plate sample also presented an oxygen analysis value above the standard. The results indicated that the physical properties and chemical compositions of the plates and screws did not correspond with the need to remove these devices or the time of retention.
Resumo:
This study was designed to evaluate the correlation between computed tomography findings and data from the physical examination and the Friedman Staging System (FSS) in patients with obstructive sleep apnea (OSA). We performed a retrospective evaluation by reviewing the medical records of 33 patients (19 male and 14 female patients) with a mean body mass index of 30.38 kg/m(2) and mean age of 49.35 years. Among these patients, 14 presented with severe OSA, 7 had moderate OSA, 7 had mild OSA, and 5 were healthy. The patients were divided into 2 groups according to the FSS: Group A comprised patients with FSS stage I or II, and group B comprised patients with FSS stage III. By use of the Fisher exact test, a positive relationship between the FSS stage and apnea-hypopnea index (P = .011) and between the FSS stage and body mass index (P = .012) was found. There was no correlation between age (P = .55) and gender (P = .53) with the FSS stage. The analysis of variance test comparing the upper airway volume between the 2 groups showed P = .018. In this sample the FSS and upper airway volume showed an inverse correlation and were useful in analyzing the mechanisms of airway collapse in patients with OSA.
Resumo:
Perineural invasion (PNI) and lymphovascular invasion (LVI) have been associated with the risk of local recurrences and lymph node metastasis. The aim of this study was to evaluate the prognostic impact of PNI and LVI in patients with advanced stage squamous cell carcinoma of the tongue and floor of the mouth. One hundred and forty-two patients without previous treatment were selected. These patients underwent radical surgery with neck dissection and adjuvant treatment. Clinicopathological data were retrieved from the medical charts, including histopathology and surgery reports. Univariate analysis was performed to assess the impact of studied variables on survival. Overall survival was negatively influenced by six tumour-related factors: increasing T stage (P = 0.003), more than two clinically positive nodes (P = 0.002), extracapsular spread of lymph node metastasis (P < 0.001), tumour thickness (P = 0.04), PNI (P < 0.001), and LVI (P = 0.012). Disease-free survival was influenced by PNI (P = 0.04), extracapsular spread of lymph node metastasis (P = 0.008), and N stage (P = 0.006). Multivariate analysis showed PNI to be an independent predictor for overall survival (P = 0.01) and disease-free survival (P = 0.03). Thus the presence of PNI in oral carcinoma surgical specimens has a significant impact on survival outcomes in patients with advanced stage tumours submitted to radical surgery and adjuvant radiotherapy/radiochemotherapy.
Resumo:
The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction