10 resultados para Limit of a function schema
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
To assess sexual function (SF) and quality of life (QOL) in women with polycystic ovary syndrome (PCOS). A cross-sectional study was conducted to assess 56 women with PCOS and 102 control women with regular menstrual cycles. To assess SF and QOL in Brazilian women with PCOS with Female Sexual Function Index (FSFI) and the WHOQOL-bref questionnaires. Women with PCOS had a worse evaluation to arousal, lubrication, satisfaction, pain and total FSFI, and there was no difference in sexual desire and orgasm. Besides, they had a worse evaluation concerning health status than controls. The body mass index was inversely correlated to the QOL, especially to the physical, psychological, environment aspects and self-assessment of QOL, but it did not show correlation to the SF. Women with PCOS had a worse sexual function and self-assessment of health condition in comparison to controls. The body weight as isolated symptom was correlated to the worsening in quality of life, but not with the worsening of sexual function.
Resumo:
Women with premature ovarian failure (POF) often manifest complaints involving different aspects of sexual function (SF), regardless of using hormone therapy. SF involves a complex interaction between physical, psychological, and sociocultural aspects. There are doubts about the impact of different complaints on the global context of SF of women with POF. To evaluate the percentage of influence of each of the sexuality domains on the SF in women with POF. Cross-sectional study with 80 women with POF, matched by age to 80 women with normal gonadal function. We evaluated SF through the Female Sexual Function Index (FSFI), a comparison between the POF and control groups using the Mann-Whitney test. Component exploratory factor analysis was used to assess the proportional influence of each domain on the composition of the overall SF for women in the POF group. SF was evaluated using FSFI. Exploratory Factor Analysis for components was used to evaluate the role of each domain on the SF of women with POF. The FSFI score was significantly worse for women with POF, with a decrease in arousal, lubrication, orgasm, satisfaction, and dyspareunia. Exploratory factor analysis of SF showed that the domain with greater influence in the SF was arousal, followed by desire, together accounting for 41% of the FSFI. The domains with less influence were dyspareunia and lubrication, which together accounted for 25% of the FSFI. Women with POF have impaired SF, determined mainly by changes in arousal and desire. Aspects related to lubrication and dyspareunia complaints have lower determination coefficient in SF. These results are important in adapting the approach of sexual disorders in this group of women. Benetti-Pinto CL, Soares PM, Giraldo HPD, and Yela DA. Role of the different sexuality domains on the sexual function of women with premature ovarian failure. J Sex Med 2015;12:685-689.
Resumo:
The present paper describes a novel, simple and reliable differential pulse voltammetric method for determining amitriptyline (AMT) in pharmaceutical formulations. It has been described for many authors that this antidepressant is electrochemically inactive at carbon electrodes. However, the procedure proposed herein consisted in electrochemically oxidizing AMT at an unmodified carbon nanotube paste electrode in the presence of 0.1 mol L(-1) sulfuric acid used as electrolyte. At such concentration, the acid facilitated the AMT electroxidation through one-electron transfer at 1.33 V vs. Ag/AgCl, as observed by the augmentation of peak current. Concerning optimized conditions (modulation time 5 ms, scan rate 90 mV s(-1), and pulse amplitude 120 mV) a linear calibration curve was constructed in the range of 0.0-30.0 μmol L(-1), with a correlation coefficient of 0.9991 and a limit of detection of 1.61 μmol L(-1). The procedure was successfully validated for intra- and inter-day precision and accuracy. Moreover, its feasibility was assessed through analysis of commercial pharmaceutical formulations and it has been compared to the UV-vis spectrophotometric method used as standard analytical technique recommended by the Brazilian Pharmacopoeia.
Resumo:
Plackett-Burman experimental design was applied for the robustness assessment of GC×GC-qMS (Comprehensive Two-Dimensional Gas Chromatography with Fast Quadrupolar Mass Spectrometric Detection) in quantitative and qualitative analysis of volatiles compounds from chocolate samples isolated by headspace solid-phase microextraction (HS-SPME). The influence of small changes around the nominal level of six factors deemed as important on peak areas (carrier gas flow rate, modulation period, temperature of ionic source, MS photomultiplier power, injector temperature and interface temperature) and of four factors considered as potentially influential on spectral quality (minimum and maximum limits of the scanned mass ranges, ions source temperature and photomultiplier power). The analytes selected for the study were 2,3,5-trimethylpyrazine, 2-octanone, octanal, 2-pentyl-furan, 2,3,5,6-tetramethylpyrazine, and 2-nonanone e nonanal. The factors pointed out as important on the robustness of the system were photomultiplier power for quantitative analysis and lower limit of mass scanning range for qualitative analysis.
Resumo:
The objective of this study was to analyze the prevalence of diabetes in older people and the adopted control measures. Data regarding older diabetic individuals who participated in the Health Surveys conducted in the Municipality of Sao Paulo, SP, ISA-Capital, in 2003 and 2008, which were cross-sectional studies, were analyzed. Prevalences and confidence intervals were compared between 2003 and 2008, according to sociodemographic variables. The combination of the databases was performed when the confidence intervals overlapped. The Chi-square (level of significance of 5%) and the Pearson's Chi-square (Rao-Scott) tests were performed. The variables without overlap between the confidence intervals were not tested. The age of the older adults was 60-69 years. The majority were women, Caucasian, with an income of between > 0.5 and 2.5 times the minimum salary and low levels of schooling. The prevalence of diabetes was 17.6% (95%CI 14.9;20.6) in 2003 and 20.1% (95%CI 17.3;23.1) in 2008, which indicates a growth over this period (p at the limit of significance). The most prevalent measure adopted by the older adults to control diabetes was hypoglycemic agents, followed by diet. Physical activity was not frequent, despite the significant differences observed between 2003 and 2008 results. The use of public health services to control diabetes was significantly higher in older individuals with lower income and lower levels of education. Diabetes is a complex and challenging disease for patients and the health systems. Measures that encourage health promotion practices are necessary because they presented a smaller proportion than the use of hypoglycemic agents. Public health policies should be implemented, and aimed mainly at older individuals with low income and schooling levels. These changes are essential to improve the health condition of older diabetic patients.
Resumo:
Purpose After a successful pyeloplasty at 3 to 6 months, the question remains whether children need a long follow-up. Methods The medical charts of patients with long-term follow-up (> 5 years), who underwent dismembered pyeloplasty for uretero-pelvic junction obstruction (UPJO) from May 1998 to May 2007, excluding those with bilateral UPJO, solitary kidney, associated vesicoureteral reflux or other abnormalities, and inconclusive renogram due to poor renal function, were retrospectively reviewed. Ultrasonography, differential renal function (DRF, DMSA), and renal drainage on diuretic renography (diethylene-triamine-pentaacetate technetium-99 or DTPA-Tc99) were performed at 3 and 6 months every year. Results Complete data were available for 28 consecutive patients (28 renal unities) with 2 months to 12 years (mean age, 2.4 years) at surgery, of whom 21 (75%) were boys, 17 diagnosed prenatally (61%) and 18 unities (64.3%) were left, with median follow-up of 10.7 years. Images were graded according to the Society for Fetal Urology grading system: Grade III in 11 (49%) and grade IV in 17 (61%). All cases presented > 10% DRF (DMSA) and obstructed DTPA-Tc99. The T1/2 (the half-time of drainage) less than 20 minutes at 3 months was found in 21 cases (75%) and less than 25 minutes in 7 cases (25%). Renal function and patency were maintained during follow-up for all units with 8% maximum fluctuation of DRF. One index case (3.6%) of renal function deterioration presented DRF fluctuation > 8% at 3 months (from 23 to 32%) and progressive hydronephrosis and indeterminate DTPA at 6 months. Conclusions Satisfactory diuretic renogram at 3 to 6 months after pyeloplasty with maintained renal function and stable hydronephrosis suggests no need for further follow-up and indicates no functional loss with time. More than 8% DRF fluctuation might be a significant cutoff for further intervention aiming nephron preservation.
Resumo:
Nanorap is a new nanotechnological formulation for topical anesthesia composed of lidocaine (2.5%) and prilocaine (2.5%). The present study evaluated the pharmacokinetics (PK) of Nanorap. For the determination of lidocaine and prilocaine in human plasma a new method using high-performance liquid-chromatography coupled to tandem mass spectrometry was developed. Nanorap pharmacodynamic (PD) and its physical proprieties were also evaluated. Nanorap was administered by topical application of 2g to healthy volunteers and blood samples were collected for the PK analysis. The drugs were extracted from plasma by liquid-liquid extraction with ether/hexane (80/20, v/v). The chromatography separation was performed on a Genesis C18 analytical column 4 µm (100 x 2.1 mm i.d.) with a mobile phase of methanol/acetonitrile/water (40/30/30, for lidocaine, and 50/30/20, for prilocaine, v/v/v) + 2 mM of ammonium acetate and ropivacaine as internal standard. The drugs were quantified using a mass spectrometer with an electrospray source in the ESI positive mode (ES+) configured for multiple reaction monitoring. The PD of Nanorap was evaluated with the use of a visual analogue scale. Nanorap was characterized by cryofracture. The chromatography run time was 5.5 min for lidocaine and 3.3 min for prilocaine and the lower limit of quantification was 0.05 ng/mL for both drugs. Mean Cmax was 6.62 and 1.72 ng/mL for lidocaine and prilocaine, respectively. Median Tmax was 6.5 hours for both drugs. Nanocapsules had a mean size of 88nm and mean drug association of 92.5% and 89% for lidocaine and prilocaine, respectively. The PD study showed that Nanorap has a sufficient analgesic effect (>30% reduction in pain) after 10 minutes of application. A new simple, selective and sensitive method for determination of lidocaine and prilocaine in human plasma was developed. Nanorap generated safe plasma levels of the drugs and satisfactory analgesic effect.
Resumo:
A novel capillary electrophoresis method using capacitively coupled contactless conductivity detection is proposed for the determination of the biocide tetrakis(hydroxymethyl)phosphonium sulfate. The feasibility of the electrophoretic separation of this biocide was attributed to the formation of an anionic complex between the biocide and borate ions in the background electrolyte. Evidence of this complex formation was provided by (11) B NMR spectroscopy. A linear relationship (R(2) = 0.9990) between the peak area of the complex and the biocide concentration (50-900 μmol/L) was found. The limit of detection and limit of quantification were 15.0 and 50.1 μmol/L, respectively. The proposed method was applied to the determination of tetrakis(hydroxymethyl)phosphonium sulfate in commercial formulations, and the results were in good agreement with those obtained by the standard iodometric titration method. The method was also evaluated for the analysis of tap water and cooling water samples treated with the biocide. The results of the recovery tests at three concentration levels (300, 400, and 600 μmol/L) varied from 75 to 99%, with a relative standard deviation no higher than 9%.
Resumo:
The aim of this study was to develop a methodology using Raman hyperspectral imaging and chemometric methods for identification of pre- and post-blast explosive residues on banknote surfaces. The explosives studied were of military, commercial and propellant uses. After the acquisition of the hyperspectral imaging, independent component analysis (ICA) was applied to extract the pure spectra and the distribution of the corresponding image constituents. The performance of the methodology was evaluated by the explained variance and the lack of fit of the models, by comparing the ICA recovered spectra with the reference spectra using correlation coefficients and by the presence of rotational ambiguity in the ICA solutions. The methodology was applied to forensic samples to solve an automated teller machine explosion case. Independent component analysis proved to be a suitable method of resolving curves, achieving equivalent performance with the multivariate curve resolution with alternating least squares (MCR-ALS) method. At low concentrations, MCR-ALS presents some limitations, as it did not provide the correct solution. The detection limit of the methodology presented in this study was 50μgcm(-2).
Resumo:
Although Brazil is the third largest fruit producer in the world, several specimens consumed are not well studied from the chemical viewpoint, especially for quantitative analysis. For this reason and the crescent employment of mass spectrometry (MS) techniques in food science we selected twenty-two phenolic compounds with important biological activities and developed an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method using electrospray (ESI) in negative ion mode aiming their quantification in largely consumed Brazilian fruits (açaí-do-Amazonas, acerola, cashew apple, camu-camu, pineapple and taperebá). Multiple reaction monitoring (MRM) was applied and the selection of proper product ions for each transition assured high selectivity. Linearity (0.995