6 resultados para Joint element

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although various abutment connections and materials have recently been introduced, insufficient data exist regarding the effect of stress distribution on their mechanical performance. The purpose of this study was to investigate the effect of different abutment materials and platform connections on stress distribution in single anterior implant-supported restorations with the finite element method. Nine experimental groups were modeled from the combination of 3 platform connections (external hexagon, internal hexagon, and Morse tapered) and 3 abutment materials (titanium, zirconia, and hybrid) as follows: external hexagon-titanium, external hexagon-zirconia, external hexagon-hybrid, internal hexagon-titanium, internal hexagon-zirconia, internal hexagon-hybrid, Morse tapered-titanium, Morse tapered-zirconia, and Morse tapered-hybrid. Finite element models consisted of a 4×13-mm implant, anatomic abutment, and lithium disilicate central incisor crown cemented over the abutment. The 49 N occlusal loading was applied in 6 steps to simulate the incisal guidance. Equivalent von Mises stress (σvM) was used for both the qualitative and quantitative evaluation of the implant and abutment in all the groups and the maximum (σmax) and minimum (σmin) principal stresses for the numerical comparison of the zirconia parts. The highest abutment σvM occurred in the Morse-tapered groups and the lowest in the external hexagon-hybrid, internal hexagon-titanium, and internal hexagon-hybrid groups. The σmax and σmin values were lower in the hybrid groups than in the zirconia groups. The stress distribution concentrated in the abutment-implant interface in all the groups, regardless of the platform connection or abutment material. The platform connection influenced the stress on abutments more than the abutment material. The stress values for implants were similar among different platform connections, but greater stress concentrations were observed in internal connections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the peripheral effect of 15-deoxy-Δ12,14-prostaglandin J2 (15d-PGJ2) in albumin-induced arthritis in temporomandibular joint (TMJ) of rats. Antigen-induced arthritis (AIA) was generated in rats with methylated bovine serum albumin (mBSA) diluted in complete Freund׳s adjuvant. Pretreatment with an intra-articular injection of 15d-PGJ2 (100 ng/TMJ) before mBSA intra-articular injection (10 µg/TMJ) (challenge) in immunized rats significantly reduced the albumin-induced arthritis inflammation. The results demonstrated that 15d-PGJ2 was able to inhibit plasma extravasation, leukocyte migration and the release of inflammatory cytokines IL-6, IL-12, IL-18 and the chemokine CINC-1 in the TMJ tissues. In addition, 15d-PGJ2 was able to increase the expression of the anti-adhesive molecule CD55 and the anti-inflammatory cytokine IL-10. Taken together, it is possible to suggest that 15d-PGJ2 inhibit leukocyte infiltration and subsequently inflammatory process, through a shift in the balance of the pro- and anti-adhesive properties. Thus, 15d-PGJ2 might be used as a potential anti-inflammatory drug to treat arthritis-induced inflammation of the temporomandibular joint.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously demonstrated that blockade of β-adrenoreceptors (β-AR) located in the temporomandibular joint (TMJ) of rats suppresses formalin-induced TMJ nociceptive behaviour in both male and female rats, but female rats are more responsive. In this study, we investigated whether gonadal hormones modulate the responsiveness to local β-blocker-induced antinociception in the TMJ of rats. Co-administration of each of the selective β1 (atenolol), β2 (ICI 118.551) and β3 (SR59230A)-AR antagonists with equi-nociceptive concentrations of formalin in the TMJ of intact, gonadectomized and hormone-treated gonadectomized male and female rats. Atenolol, ICI 118.551 and SR59230A significantly reduced formalin-induced TMJ nociception in a dose response fashion in all groups tested. However, a lower dose of each β-AR antagonist was sufficient to significantly reduce nociceptive responses in gonadectomized but not in intact and testosterone-treated gonadectomized male rats. In the female groups, a lower dose of β1 -AR antagonist was sufficient to significantly reduce nociceptive responses in gonadectomized but not in intact or gonadectomized rats treated with progesterone or a high dose of oestradiol; a lower dose of β2 -AR antagonist was sufficient to significantly reduce nociceptive responses in gonadectomized but not in intact and gonadectomized rats treated with low or high dose of oestradiol. Gonadal hormones may reduce the responsiveness to local β-blocker-induced antinociception in the TMJ of male and female rats. However, their effect depends upon their plasma level, the subtype of β-AR and the dose of β-blockers used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study proposed to evaluate the mandibular biomechanics in the posterior dentition based on experimental and computational analyses. The analyses were performed on a model of human mandible, which was modeled by epoxy resin for photoelastic analysis and by computer-aided design for finite element analysis. To standardize the evaluation, specific areas were determined at the lateral surface of mandibular body. The photoelastic analysis was configured through a vertical load on the first upper molar and fixed support at the ramus of mandible. The same configuration was used in the computer simulation. Force magnitudes of 50, 100, 150, and 200 N were applied to evaluate the bone stress. The stress results presented similar distribution in both analyses, with the more intense stress being at retromolar area and oblique line and alveolar process at molar level. This study presented the similarity of results in the experimental and computational analyses and, thus, showed the high importance of morphology biomechanical characterization at posterior dentition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Maxillofacial trauma resulting from falls in elderly patients is a major social and health care concern. Most of these traumatic events involve mandibular fractures. The aim of this study was to analyze stress distributions from traumatic loads applied on the symphyseal, parasymphyseal, and mandibular body regions in the elderly edentulous mandible using finite-element analysis (FEA). Computerized tomographic analysis of an edentulous macerated human mandible of a patient approximately 65 years old was performed. The bone structure was converted into a 3-dimensional stereolithographic model, which was used to construct the computer-aided design (CAD) geometry for FEA. The mechanical properties of cortical and cancellous bone were characterized as isotropic and elastic structures, respectively, in the CAD model. The condyles were constrained to prevent free movement in the x-, y-, and z-axes during simulation. This enabled the simulation to include the presence of masticatory muscles during trauma. Three different simulations were performed. Loads of 700 N were applied perpendicular to the surface of the cortical bone in the symphyseal, parasymphyseal, and mandibular body regions. The simulation results were evaluated according to equivalent von Mises stress distributions. Traumatic load at the symphyseal region generated low stress levels in the mental region and high stress levels in the mandibular neck. Traumatic load at the parasymphyseal region concentrated the resulting stress close to the mental foramen. Traumatic load in the mandibular body generated extensive stress in the mandibular body, angle, and ramus. FEA enabled precise mapping of the stress distribution in a human elderly edentulous mandible (neck and mandibular angle) in response to 3 different traumatic load conditions. This knowledge can help guide emergency responders as they evaluate patients after a traumatic event.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To characterize cumulative joint damage (CJD) patterns in rheumatoid arthritis (RA) and determine their associations with demographic/clinical features and HLA-DRB1 gene polymorphism. Hand and foot radiographs were obtained from 404 patients with RA. CJD patterns were determined by 3 derivations from Sharp/van der Heijde scores, obtained by the mathematical division of scores for hands/feet (Sharp-h/f score), fingers/wrists (Sharp-f/w score), and erosion/space narrowing (Sharp-e/sn score), respectively. DNA and serum were obtained for determination of HLA-DRB1 polymorphism, rheumatoid factor (RF), and anticitrullinated protein antibodies (ACPA). Patients with wrist-dominant CJD pattern were more likely to have severe RA than those with finger-dominant pattern (68.4% vs 46.0%; p = 0.036) as were those with foot-dominant vs hand-dominant CJD pattern (76.5% vs 56.4%; p = 0.044). HLA-DRB1 shared epitope (SE) alleles were associated with erosion-dominant CJD pattern (p = 0.021). Patients with erosion-dominant CJD pattern had higher levels of RF and ACPA than those with space-narrowing-dominant CJD pattern (median RF 71.35 U/ml vs 22.05 U/ml, respectively; p = 0.003; median ACPA 187.9 U/ml vs 143.2 U/ml, respectively; p < 0.001). The majority of triple-positive patients (SE+, RF+, ACPA+) had erosion-dominant CJD pattern (62.3%) while the majority of triple-negative patients (SE-, FR-, ACPA-) had space narrowing-dominant CJD pattern (75%; p = 0.017). ACPA was associated with HLA-DRB1 SE alleles (p < 0.05). Patients with foot-dominant CJD pattern were taller than those with hand-dominant CJD pattern (p = 0.002); those with erosion-dominant CJD pattern had higher weight and body mass index than those with space narrowing-dominant CJD pattern (p = 0.014, p = 0.001). CJD patterns were associated with disease severity, HLA-DRB1 SE status, presence and titer of ACPA and RF, and morphometric features.