16 resultados para High-performance liquid chromatographic

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, sensitive and specific method for quantifying propylthiouracil in human plasma using methylthiouracil as the internal standard (IS) is described. The analyte and the IS were extracted from plasma by liquid-liquid extraction using an organic solvent (ethyl acetate). The extracts were analyzed by high performance liquid chromatography coupled with electrospray tandem mass spectrometry (HPLC-MS/MS) in negative mode (ES-). Chromatography was performed using a Phenomenex Gemini C18 5μm analytical column (4.6mm×150mm i.d.) and a mobile phase consisting of methanol/water/acetonitrile (40/40/20, v/v/v)+0.1% of formic acid. For propylthiouracil and I.S., the optimized parameters of the declustering potential, collision energy and collision exit potential were -60 (V), -26 (eV) and -5 (V), respectively. The method had a chromatographic run time of 2.5min and a linear calibration curve over the range 20-5000ng/mL. The limit of quantification was 20ng/mL. The stability tests indicated no significant degradation. This HPLC-MS/MS procedure was used to assess the bioequivalence of two propylthiouracil 100mg tablet formulations in healthy volunteers of both sexes in fasted and fed state. The geometric mean and 90% confidence interval CI of Test/Reference percent ratios were, without and with food, respectively: 109.28% (103.63-115.25%) and 115.60% (109.03-122.58%) for Cmax, 103.31% (100.74-105.96%) and 103.40% (101.03-105.84) for AUClast. This method offers advantages over those previously reported, in terms of both a simple liquid-liquid extraction without clean-up procedures, as well as a faster run time (2.5min). The LOQ of 20ng/mL is well suited for pharmacokinetic studies. The assay performance results indicate that the method is precise and accurate enough for the routine determination of the propylthiouracil in human plasma. The test formulation with and without food was bioequivalent to reference formulation. Food administration increased the Tmax and decreased the bioavailability (Cmax and AUC).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of antioxidants either to prevent or retard food's lipids oxidation was approved after inquires that verified their security within a daily intake limit. In this study, the methodology was developed and validated for the analysis of synthetic antioxidants: propylgallate (PG), tert-butylhydroquinone (TBHQ), butylhydroxyanisole (BHA), octylgallate (OG) and butylhydroxytoluene (BHT) in vegetables oils, margarine and hydrogenated fats by high performance liquid chromatographic. The methodology revealed itself efficient, with recovery rates above 90% for all antioxidant substances, besides good linearity in concentration range of 40-240 mg kg-1 (r = 0,999), repeatability with CV < 3,7% and limit of quantification 16.55, 10.32, 1.40, 3.76 and 9.30 mg/kg for BHT, BHA, PG, OG and TBHQ, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Monolithic stationary phases represent a new generation of chromatographic separation media. These phases consist of a continuous separation bed prepared by in situ polymerization or consolidation inside the column tubing. In recent years, their simple preparation procedure, unique properties and excellent performance have attracted quite remarkable attention in liquid chromatography and capillary electrochromatography. This review summarizes the preparation, characterization and applications of monolithic stationary phases. The analytical potential of these columns is demonstrated with separations involving various families of compounds in different separation modes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study analyzed metallothionein (MT) excretion from liver to bile in Nile Tilapia (Oreochromis niloticus) exposed to sub-lethal copper concentrations (2mgL(-1)) in a laboratory setting. MTs in liver and bile were quantified by spectrophotometry after thermal incubation and MT metal-binding profiles were characterized by size exclusion high performance liquid chromatography coupled to ICP-MS (SEC-HPLC-ICP-MS). Results show that liver MT is present in approximately 250-fold higher concentrations than bile MT in non-exposed fish. Differences between the MT profiles from the control and exposed group were observed for both matrices, indicating differential metal-binding behavior when comparing liver and bile MT. This is novel data regarding intra-organ MT comparisons, since differences between organs are usually present only with regard to quantification, not metal-binding behavior. Bile MT showed statistically significant differences between the control and exposed group, while the same did not occur with liver MT. This indicates that MTs synthesized in the liver accumulate more slowly than MTs excreted from liver to bile, since the same fish presented significantly higher MT levels in liver when compared to bile. We postulate that bile, although excreted in the intestine and partially reabsorbed by the same returning to the liver, may also release MT-bound metals more rapidly and efficiently, which may indicate an efficient detoxification route. Thus, we propose that the analysis of bile MTs to observe recent metal exposure may be more adequate than the analysis of liver MTs, since organism responses to metals are more quickly observed in bile, although further studies are necessary.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Extracts from malagueta pepper (Capsicum frutescens L.) were obtained using supercritical fluid extraction (SFE) assisted by ultrasound, with carbon dioxide as solvent at 15MPa and 40°C. The SFE global yield increased up to 77% when ultrasound waves were applied, and the best condition of ultrasound-assisted extraction was ultrasound power of 360W applied during 60min. Four capsaicinoids were identified in the extracts and quantified by high performance liquid chromatography. The use of ultrasonic waves did not influence significantly the capsaicinoid profiles and the phenolic content of the extracts. However, ultrasound has enhanced the SFE rate. A model based on the broken and intact cell concept was adequate to represent the extraction kinetics and estimate the mass transfer coefficients, which were increased with ultrasound. Images obtained by field emission scanning electron microscopy showed that the action of ultrasonic waves did not cause cracks on the cell wall surface. On the other hand, ultrasound promoted disturbances in the vegetable matrix, leading to the release of extractable material on the solid surface. The effects of ultrasound were more significant on SFE from larger solid particles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nanorap is a new nanotechnological formulation for topical anesthesia composed of lidocaine (2.5%) and prilocaine (2.5%). The present study evaluated the pharmacokinetics (PK) of Nanorap. For the determination of lidocaine and prilocaine in human plasma a new method using high-performance liquid-chromatography coupled to tandem mass spectrometry was developed. Nanorap pharmacodynamic (PD) and its physical proprieties were also evaluated. Nanorap was administered by topical application of 2g to healthy volunteers and blood samples were collected for the PK analysis. The drugs were extracted from plasma by liquid-liquid extraction with ether/hexane (80/20, v/v). The chromatography separation was performed on a Genesis C18 analytical column 4 µm (100 x 2.1 mm i.d.) with a mobile phase of methanol/acetonitrile/water (40/30/30, for lidocaine, and 50/30/20, for prilocaine, v/v/v) + 2 mM of ammonium acetate and ropivacaine as internal standard. The drugs were quantified using a mass spectrometer with an electrospray source in the ESI positive mode (ES+) configured for multiple reaction monitoring. The PD of Nanorap was evaluated with the use of a visual analogue scale. Nanorap was characterized by cryofracture. The chromatography run time was 5.5 min for lidocaine and 3.3 min for prilocaine and the lower limit of quantification was 0.05 ng/mL for both drugs. Mean Cmax was 6.62 and 1.72 ng/mL for lidocaine and prilocaine, respectively. Median Tmax was 6.5 hours for both drugs. Nanocapsules had a mean size of 88nm and mean drug association of 92.5% and 89% for lidocaine and prilocaine, respectively. The PD study showed that Nanorap has a sufficient analgesic effect (>30% reduction in pain) after 10 minutes of application. A new simple, selective and sensitive method for determination of lidocaine and prilocaine in human plasma was developed. Nanorap generated safe plasma levels of the drugs and satisfactory analgesic effect.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this research was to investigate the antiproliferative and anticholinesterase activities of 11 extracts from 5 Annonaceae species in vitro. Antiproliferative activity was assessed using 10 human cancer cell lines. Thin-layer chromatography and a microplate assay were used to screen the extracts for acetylcholinesterase (AchE) inhibitors using Ellman's reagent. The chemical compositions of the active extracts were investigated using high performance liquid chromatography. Eleven extracts obtained from five Annonaceae plant species were active and were particularly effective against the UA251, NCI-470 lung, HT-29, NCI/ADR, and K-562 cell lines with growth inhibition (GI50) values of 0.04-0.06, 0.02-0.50, 0.01-0.12, 0.10-0.27, and 0.02-0.04 µg/mL, respectively. In addition, the Annona crassiflora and A. coriacea seed extracts were the most active among the tested extracts and the most effective against the tumor cell lines, with GI50 values below 8.90 µg/mL. The A. cacans extract displayed the lowest activity. Based on the microplate assay, the percent AchE inhibition of the extracts ranged from 12 to 52%, and the A. coriacea seed extract resulted in the greatest inhibition (52%). Caffeic acid, sinapic acid, and rutin were present at higher concentrations in the A. crassiflora seed samples. The A. coriacea seeds contained ferulic and sinapic acid. Overall, the results indicated that A. crassiflora and A. coriacea extracts have antiproliferative and anticholinesterase properties, which opens up new possibilities for alternative pharmacotherapy drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although Brazil is the third largest fruit producer in the world, several specimens consumed are not well studied from the chemical viewpoint, especially for quantitative analysis. For this reason and the crescent employment of mass spectrometry (MS) techniques in food science we selected twenty-two phenolic compounds with important biological activities and developed an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method using electrospray (ESI) in negative ion mode aiming their quantification in largely consumed Brazilian fruits (açaí-do-Amazonas, acerola, cashew apple, camu-camu, pineapple and taperebá). Multiple reaction monitoring (MRM) was applied and the selection of proper product ions for each transition assured high selectivity. Linearity (0.99580%), precision (CV<20%) and extraction recovery rate (>80%) were satisfactory and showed that the method provides an efficient protocol to analyze phenolic compounds in fruit pulp extracts.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ropivacaine (RVC) is an aminoamide local anesthetic widely used in surgical procedures. Studies with RVC encapsulated in liposomes and complexed in cyclodextrins have shown good results, but in order to use RVC for lengthy procedures and during the postoperative period, a still more prolonged anesthetic effect is required. This study therefore aimed to provide extended RVC release and increased upload using modified liposomes. Three types of vesicles were studied: (i) large multilamellar vesicle (LMV), (ii) large multivesicular vesicle (LMVV) and (iii) large unilamellar vesicle (LUV), prepared with egg phosphatidylcholine/cholesterol/α-tocopherol (4:3:0.07 mol%) at pH 7.4. Ionic gradient liposomes (inside: pH 5.5, pH 5.5 + (NH4)2SO4 and pH 7.4 + (NH4)2SO4) were prepared and showed improved RVC loading, compared to conventional liposomes (inside: pH 7.4). An high-performance liquid chromatography analytical method was validated for RVC quantification. The liposomes were characterized in terms of their size, zeta potential, polydispersion, morphology, RVC encapsulation efficiency (EE(%)) and in vitro RVC release. LMVV liposomes provided better performance than LMV or LUV. The best formulations were prepared using pH 5.5 (LMVV 5.5in) or pH 7.4 with 250 mM (NH4)2SO4 in the inner aqueous core (LMVV 7.4in + ammonium sulfate), enabling encapsulation of as much as 2% RVC, with high uptake (EE(%) ∼70%) and sustained release (∼25 h). The encapsulation of RVC in ionic gradient liposomes significantly extended the duration of release of the anesthetic, showing that this strategy could be a viable means of promoting longer-term anesthesia during surgical procedures and during the postoperative period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions. Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high-performance liquid chromatography (HPLC) and high-resolution electrospray ionization mass spectrometry (ESI-(+)-MS) and characterized according to US Pharmacopeia. There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high-resolution ESI-(+)-MS analyses show that brand B contains approximately 2.7 times more hydrolysed cisplatin than brand A. The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high-resolution ESI-(+)-MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method to quantify lycopene and β-carotene in freeze dried tomato pulp by high performance liquid chromatography (HLPC) was validated according to the criteria of selectivity, sensitivity, precision and accuracy, and uncertainty estimation of measurement was determined with data obtained in the validation. The validated method presented is selective in terms of analysis, and it had a good precision and accuracy. Detection limit for lycopene and β-carotene was 4.2 and 0.23 mg 100 g-1, respectively. The estimation of expanded uncertainty (K = 2) for lycopene was 104 ± 21 mg 100 g-1 and for β-carotene was 6.4 ± 1.5 mg 100 g-1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Emerging organic pollutants (EOP) include many environmental contaminants based on commercial products such as pharmaceuticals, personal care products, detergents, gasoline, polymers, etc. EOP may be candidates for future regulation as they offer potential risk to environmental and human health due to their continual entrance into the environment and to the fact that even the most modern wastewater treatment plants are not able to totally transform / remove these compounds. High performance liquid chromatography is recommended to separate emerging organic pollutants with characteristics of high polarity and low volatility, especially pharmaceuticals, from environmental matrices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This review describes the advantages and disadvantages of using capillary liquid chromatography (CLC), which is considered the newest member in the analytical separation science arsenal. Although CLC has tremendous potential for being the next major innovation in separatory analysis, it has not yet obtained great popularity compared to conventional high performance (and ultra-high performance) liquid chromatography. Comparisons are made between these techniques and some of the reasons that CLC has not yet reached its potential will be advanced.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different brands and batches of brazilian regular and instant coffee were purchased in supermarkets of Campinas? city and analysed for caffeine content. The method used involved extraction with boiling water, clarification with saturated basic acetate and determination by high performance liquid cromatography. Analysis was carried out using a Model 6000 A solvent delivery system (Waters associates), and a Model 7125 sample injector system (Reodyne, Inc.) with a 5µl sample loop. The system was also equipped with a Waters Model M440 absorbance detector set at 254 nm. A Merck ODS 5µm column (15 cm x 4.6 mm i.d.) was used to separate the caffeine. The mobile phase was methanol:water (25:75, v/v). The caffeine content varied for different brands and types of coffee and according to the beverage preparation technique. Values in the range of 0.43 to 0.85 mg/ml and 0.61 to 0.82 mg/ml were determined in regular and instant coffee, respectively.