19 resultados para Gas-phase
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
We report on the shape resonance spectra of phenol-water clusters, as obtained from elastic electron scattering calculations. Our results, along with virtual orbital analysis, indicate that the well-known indirect mechanism for hydrogen elimination in the gas phase is significantly impacted on by microsolvation, due to the competition between vibronic couplings on the solute and solvent molecules. This fact suggests how relevant the solvation effects could be for the electron-driven damage of biomolecules and the biomass delignification [E. M. de Oliveira et al., Phys. Rev. A 86, 020701(R) (2012)]. We also discuss microsolvation signatures in the differential cross sections that could help to identify the solvated complexes and access the composition of gaseous admixtures of these species.
Resumo:
An absolute method is described via mass spectrometry (MS) for the structural assignment of isomers within the class of methylpiperidines. The method explores both the unimolecular and bimolecular gas phase behavior of structurally diagnostic fragment ions (SDFI). For the methylpiperidnes, the isomeric 2-methyl, 3-methyl and 4-methyl 2-azabutadienyl cations are found to function as SDFI. These fragment ions are expected to be formed from all members within the class, to be stable and to retain the structural information of the precursor molecule, and to not interconvert into one another. To characterize these SDFI, both the collision induced dissociation (CID) in argon and bimolecular ion/molecule chemistry with ethyl vinyl ether were compared.
Resumo:
Plackett-Burman experimental design was applied for the robustness assessment of GC×GC-qMS (Comprehensive Two-Dimensional Gas Chromatography with Fast Quadrupolar Mass Spectrometric Detection) in quantitative and qualitative analysis of volatiles compounds from chocolate samples isolated by headspace solid-phase microextraction (HS-SPME). The influence of small changes around the nominal level of six factors deemed as important on peak areas (carrier gas flow rate, modulation period, temperature of ionic source, MS photomultiplier power, injector temperature and interface temperature) and of four factors considered as potentially influential on spectral quality (minimum and maximum limits of the scanned mass ranges, ions source temperature and photomultiplier power). The analytes selected for the study were 2,3,5-trimethylpyrazine, 2-octanone, octanal, 2-pentyl-furan, 2,3,5,6-tetramethylpyrazine, and 2-nonanone e nonanal. The factors pointed out as important on the robustness of the system were photomultiplier power for quantitative analysis and lower limit of mass scanning range for qualitative analysis.
Resumo:
Super elastic nitinol (NiTi) wires were exploited as highly robust supports for three distinct crosslinked polymeric ionic liquid (PIL)-based coatings in solid-phase microextraction (SPME). The oxidation of NiTi wires in a boiling (30%w/w) H2O2 solution and subsequent derivatization in vinyltrimethoxysilane (VTMS) allowed for vinyl moieties to be appended to the surface of the support. UV-initiated on-fiber copolymerization of the vinyl-substituted NiTi support with monocationic ionic liquid (IL) monomers and dicationic IL crosslinkers produced a crosslinked PIL-based network that was covalently attached to the NiTi wire. This alteration alleviated receding of the coating from the support, which was observed for an analogous crosslinked PIL applied on unmodified NiTi wires. A series of demanding extraction conditions, including extreme pH, pre-exposure to pure organic solvents, and high temperatures, were applied to investigate the versatility and robustness of the fibers. Acceptable precision of the model analytes was obtained for all fibers under these conditions. Method validation by examining the relative recovery of a homologous group of phthalate esters (PAEs) was performed in drip-brewed coffee (maintained at 60 °C) by direct immersion SPME. Acceptable recoveries were obtained for most PAEs in the part-per-billion level, even in this exceedingly harsh and complex matrix.
Resumo:
In this work, we discuss the use of multi-way principal component analysis combined with comprehensive two-dimensional gas chromatography to study the volatile metabolites of the saprophytic fungus Memnoniella sp. isolated in vivo by headspace solid-phase microextraction. This fungus has been identified as having the ability to induce plant resistance against pathogens, possibly through its volatile metabolites. Adequate culture media was inoculated, and its headspace was then sampled with a solid-phase microextraction fiber and chromatographed every 24 h over seven days. The raw chromatogram processing using multi-way principal component analysis allowed the determination of the inoculation period, during which the concentration of volatile metabolites was maximized, as well as the discrimination of the appropriate peaks from the complex culture media background. Several volatile metabolites not previously described in the literature on biocontrol fungi were observed, as well as sesquiterpenes and aliphatic alcohols. These results stress that, due to the complexity of multidimensional chromatographic data, multivariate tools might be mandatory even for apparently trivial tasks, such as the determination of the temporal profile of metabolite production and extinction. However, when compared with conventional gas chromatography, the complex data processing yields a considerable improvement in the information obtained from the samples. This article is protected by copyright. All rights reserved.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Phase I trials use a small number of patients to define a maximum tolerated dose (MTD) and the safety of new agents. We compared data from phase I and registration trials to determine whether early trials predicted later safety and final dose. We searched the U.S. Food and Drug Administration (FDA) website for drugs approved in nonpediatric cancers (January 1990-October 2012). The recommended phase II dose (R2PD) and toxicities from phase I were compared with doses and safety in later trials. In 62 of 85 (73%) matched trials, the dose from the later trial was within 20% of the RP2D. In a multivariable analysis, phase I trials of targeted agents were less predictive of the final approved dose (OR, 0.2 for adopting ± 20% of the RP2D for targeted vs. other classes; P = 0.025). Of the 530 clinically relevant toxicities in later trials, 70% (n = 374) were described in phase I. A significant relationship (P = 0.0032) between increasing the number of patients in phase I (up to 60) and the ability to describe future clinically relevant toxicities was observed. Among 28,505 patients in later trials, the death rate that was related to drug was 1.41%. In conclusion, dosing based on phase I trials was associated with a low toxicity-related death rate in later trials. The ability to predict relevant toxicities correlates with the number of patients on the initial phase I trial. The final dose approved was within 20% of the RP2D in 73% of assessed trials.
Resumo:
Obstructive lung diseases of different etiologies present with progressive peripheral airway involvement. The peripheral airways, known as the silent lung zone, are not adequately evaluated with conventional function tests. The principle of gas washout has been used to detect pulmonary ventilation inhomogeneity and to estimate the location of the underlying disease process. Volumetric capnography (VC) analyzes the pattern of CO2 elimination as a function of expired volume. To measure normalized phase 3 slopes with VC in patients with non-cystic fibrosis bronchiectasis (NCB) and in bronchitic patients with chronic obstructive pulmonary disease (COPD) in order to compare the slopes obtained for the groups. NCB and severe COPD were enrolled sequentially from an outpatient clinic (Hospital of the State University of Campinas). A control group was established for the NCB group, paired by sex and age. All subjects performed spirometry, VC, and the 6-Minute Walk Test (6MWT). Two comparisons were made: NCB group versus its control group, and NCB group versus COPD group. The project was approved by the ethical committee of the institution. Statistical tests used were Wilcoxon or Student's t-test; P<0.05 was considered to be a statistically significant difference. Concerning the NCB group (N=20) versus the control group (N=20), significant differences were found in body mass index and in several functional variables (spirometric, VC, 6MWT) with worse results observed in the NCB group. In the comparison between the COPD group (N=20) versus the NCB group, although patients with COPD had worse spirometric and 6MWT values, the capnographic variables mean phase 2 slope (Slp2), mean phase 3 slope normalized by the mean expiratory volume, or mean phase 3 slope normalized by the end-tidal CO2 concentration were similar. These findings may indicate that the gas elimination curves are not sensitive enough to monitor the severity of structural abnormalities. The role of normalized phase 3 slope may be worth exploring as a more sensitive index of small airway disease, even though it may not be equally sensitive in discriminating the severity of the alterations.
Resumo:
Recent data suggests that cholesteryl ester transfer protein (CETP) activity may interact with acute stress conditions via inflammatory-oxidative response and thrombogenesis. We investigated this assumption in patients with ST-elevation myocardial infarction (STEMI). Consecutive patients with STEMI (n = 116) were enrolled <24-h of symptoms onset and were followed for 180 days. Plasma levels of C-reactive protein (CRP), interleukin-2 (IL-2), tumor necrosis factor (TNFα), 8-isoprostane, nitric oxide (NOx) and CETP activity were measured at enrollment (D1) and at fifth day (D5). Flow-mediated dilation (FMD) was assessed by ultrasound and coronary thrombus burden (CTB) was evaluated by angiography. Neither baseline nor the change of CETP activity from D1 to D5 was associated with CRP, IL-2, TNFα, 8-isoprostane levels or CTB. The rise in NOx from D1 to D5 was inferior [3.5(-1; 10) vs. 5.5(-1; 12); p < 0.001] and FMD was lower [5.9(5.5) vs. 9.6(6.6); p = 0.047] in patients with baseline CETP activity above the median value than in their counterparts. Oxidized HDL was measured by thiobarbituric acid reactive substances (TBARS) in isolated HDL particles and increased from D1 to D5, and remaining elevated at D30. The change in TBARS content in HDL was associated with CETP activity (r = 0.72; p = 0.014) and FMD (r = -0.61; p = 0.046). High CETP activity at admission was associated with the incidence of sudden death and recurrent MI at 30 days (OR 12.8; 95% CI 1.25-132; p = 0.032) and 180 days (OR 3.3; 95% CI 1.03-10.7; p = 0.044). An enhanced CETP activity during acute phase of STEMI is independently associated with endothelial dysfunction and adverse clinical outcome.
Resumo:
To assess the location of hard gelatin capsules in the pharyngeal phase triggering among asymptomatic adults. The location of the bolus during the pharyngeal phase triggering provides information about the sensorimotor model of the beginning of deglutition onset. To evaluate the location of hard gelatin capsules in the pharyngeal phase triggering among asymptomatic adults. A videofluoroscopy swallowing study was carried out in 60 subjects (14 male and 46 female participants) aged between 27 and 55 years, who were evaluated with hard gelatin capsules #00 and #3 containing barium sulfate, swallowed with liquid food and pudding, in free volume. The first laryngeal elevation movement was the criterion to locate the pharyngeal phase triggering. Statistical analysis was based on the McNemar test. Capsule #3 presented higher percentage of location in the tongue dorsum compared to capsule #00, and capsule #00 presented higher percentage of location in the tongue base and vallecula compared to capsule #3. There was a difference between different capsules swallowed with liquid (p=0.016) and pudding (p=0.037). The capsule size influenced the location of the pharyngeal phase triggering. Smaller capsules started pharyngeal phase in the most anterior region (tongue dorsum) compared to larger capsules.
Resumo:
The aim of this study was to compare the performance of the following techniques on the isolation of volatiles of importance for the aroma/flavor of fresh cashew apple juice: dynamic headspace analysis using PorapakQ(®) as trap, solvent extraction with and without further concentration of the isolate, and solid-phase microextraction (fiber DVB/CAR/PDMS). A total of 181 compounds were identified, from which 44 were esters, 20 terpenes, 19 alcohols, 17 hydrocarbons, 15 ketones, 14 aldehydes, among others. Sensory evaluation of the gas chromatography effluents revealed esters (n = 24) and terpenes (n = 10) as the most important aroma compounds. The four techniques were efficient in isolating esters, a chemical class of high impact in the cashew aroma/flavor. However, the dynamic headspace methodology produced an isolate in which the analytes were in greater concentration, which facilitates their identification (gas chromatography-mass spectrometry) and sensory evaluation in the chromatographic effluents. Solvent extraction (dichloromethane) without further concentration of the isolate was the most efficient methodology for the isolation of terpenes. Because these two techniques also isolated in greater concentration the volatiles from other chemical classes important to the cashew aroma, such as aldehydes and alcohols, they were considered the most advantageous for the study of cashew aroma/flavor.
Resumo:
This work encompasses a direct and coherent strategy to synthesise a molecularly imprinted polymer (MIP) capable of extracting fluconazole from its sample. The MIP was successfully prepared from methacrylic acid (functional monomer), ethyleneglycoldimethacrylate (crosslinker) and acetonitrile (porogenic solvent) in the presence of fluconazole as the template molecule through a non-covalent approach. The non-imprinted polymer (NIP) was prepared following the same synthetic scheme, but in the absence of the template. The data obtained from scanning electronic microscopy, infrared spectroscopy, thermogravimetric and nitrogen Brunauer-Emmett-Teller plot helped to elucidate the structural as well as the morphological characteristics of the MIP and NIP. The application of MIP as a sorbent was demonstrated by packing it in solid phase extraction cartridges to extract fluconazole from commercial capsule samples through an offline analytical procedure. The quantification of fluconazole was accomplished through UPLC-MS, which resulted in LOD≤1.63×10(-10) mM. Furthermore, a high percentage recovery of 91±10% (n=9) was obtained. The ability of the MIP for selective recognition of fluconazole was evaluated by comparison with the structural analogues, miconazole, tioconazole and secnidazole, resulting in percentage recoveries of 51, 35 and 32%, respectively.
Resumo:
The development of technological routes to convert lignocellulosic biomass to liquid fuels requires an in-depth understanding of the cell wall architecture of substrates. Essential pretreatment processes are conducted to reduce biomass recalcitrance and usually increase the reactive surface area. Quantitative three-dimensional information about both bulk and surface structural features of substrates needs to be obtained to expand our knowledge of substrates. In this work, phase-contrast tomography (PCT) was used to gather information about the structure of a model lignocellulosic biomass (piassava fibers). The three-dimensional cellular organization of piassava fibers was characterized by PCT using synchrotron radiation. This technique enabled important physical features that describe the substrate piassava fibers to be visualized and quantified. The external surface area of a fiber and internal surface area of the pores in a fiber could be determined separately. More than 96% of the overall surface area available to enzymes was in the bulk substrate. The pore surface area and length exhibited a positive linear relationship, where the slope of this relationship depended on the plant tissue. We demonstrated that PCT is a powerful tool for the three-dimensional characterization of the cell wall features related to biomass recalcitrance. Original and relevant quantitative information about the structural features of the analyzed material were obtained. The data obtained by PCT can be used to improve processing routes to efficiently convert biomass feedstock into sugars.
Resumo:
Traveling wave ion mobility mass spectrometry (TWIM-MS) is shown to be able to separate and characterize several isomeric forms of diterpene glycosides stevioside (Stv) and rebaudioside A (RebA) that are cationized by Na(+) and K(+) at different sites. Determination and characterization of these coexisting isomeric species, herein termed catiomers, arising from cationization at different and highly competitive coordinating sites, is particularly challenging for glycosides. To achieve this goal, the advantage of using CO2 as a more massive and polarizable drift gas, over N2 , was demonstrated. Post-TWIM-MS/MS experiments were used to confirm the separation. Optimization of the possible geometries and cross-sectional calculations for mobility peak assignments were also performed. Copyright © 2015 John Wiley & Sons, Ltd.
Resumo:
In this work, the volatile chromatographic profiles of roasted Arabica coffees, previously analyzed for their sensorial attributes, were explored by principal component analysis. The volatile extraction technique used was the solid phase microextraction. The correlation optimized warping algorithm was used to align the gas chromatographic profiles. Fifty four compounds were found to be related to the sensorial attributes investigated. The volatiles pyrrole, 1-methyl-pyrrole, cyclopentanone, dihydro-2-methyl-3-furanone, furfural, 2-ethyl-5-methyl-pyrazine, 2-etenyl-n-methyl-pyrazine, 5-methyl-2-propionyl-furan compounds were important for the differentiation of coffee beverage according to the flavour, cleanliness and overall quality. Two figures of merit, sensitivity and specificity (or selectivity), were used to interpret the sensory attributes studied.