375 resultados para GLAUCOMA DE ÂNGULO ABERTO
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.
Resumo:
PURPOSE: To evaluate the frequency of different types of glaucoma at the Hospital das Clínicas of Campinas State University. METHODS: Cross-sectional study of 329 patients followed at the Glaucoma Service of Campinas State University from October 1 to December 20, 2000. The frequency of each type of glaucoma and the treatment were analyzed. RESULTS: There were 329 patients examined at the Glaucoma Service: 132 (40.1%) were referred to the service as glaucoma suspects and 197 (59.9%) as glaucoma patients. Ninety of the 132 glaucoma suspects had glaucoma (68.2%) and 42 are still under investigation (31.8%). Among the 329 patients, 283 (86%) had glaucoma, 42 (12.8%) were glaucoma suspects, 2 (0.6%) had ocular hypertension and 2 (0.6%) did not have glaucoma. There were 530 eyes with glaucoma: 298 (56.2%) with primary open angle glaucoma, 108 (20.4%) with chronic angle closure glaucoma, 21 (4%) with glaucoma following cataract surgery, 19 (3.6%) congenital glaucoma and 16 (3%) with low-tension glaucoma. All patients received initial clinical treatment with IOP-lowering medication. After a mean follow up of 10.5 months, 89 (16.8%) underwent laser therapy: 72 (13.6%) iridotomy, 7 (1.3%) trabeculoplasty and 10 (1.9%) panphotocoagulation. A hundred and seventy nine (33%) eyes required surgical treatment. CONCLUSION: The most frequent types of glaucoma were primary open angle and angle closure glaucoma. Low tension glaucoma and glaucoma associated with exfoliation syndrome were uncommon in this population.
Resumo:
PURPOSE: To compare the 2% ibopamine provocative test with the water drinking test as a provocative test for glaucoma. METHODS: Primary open-angle glaucoma patients and normal individuals were selected from CEROF-Universidade Federal de Goiânia UFG, and underwent the 2% ibopamine provocative test and the water drinking test in a randomized fashion, at least 1 week apart. Intraocular pressure (IOP) before and after both tests, Bland-Altman graph, sensitivity and specificity (as mesured by ROC curves) were obtained for both methods. RESULTS: Forty-seven eyes from 25 patients were included (27 eyes from 15 glaucoma patients and 20 eyes from 10 normal individuals), with a mean age of 54.2 ± 12.7 years. The mean MD of glaucoma patients was -2.8 ± 2.11 dB. There was no statistically difference in the baseline IOP (p=0.8) comparing glaucoma patients, but positive after the provocative tests (p=0.03), and in the IOP variation (4.4 ± 1.3 mmHg for ibopamine and 3.2 ± 2.2 mmHg for water drinking test, p=0.01). There was no difference in all studied parameters for normal individuals. The Bland-Altman graph showed high dispersion comparing both methods. The areas under the ROC curve were 0.987 for the ibopamine provocative test, and 0.807 for the water-drinking test. CONCLUSION: In this selected subgroup of glaucoma patients with early visual field defect, the ibopamine provocative test has shown better sensitivity/specificity than the water drinking test.
Resumo:
This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.
Resumo:
PURPOSE: To evaluate the knowledge glaucoma patients have about their disease and its treatment. METHODS: One hundred and eighty-three patients were interviewed at the Glaucoma Service of Wills Eye Hospital (Philadelphia, USA, Group 1) and 100 at the Glaucoma Service of University of Campinas (Campinas, Brazil, Group 2). An informal, relaxed atmosphere was created by the interviewer before asking a list of 18 open-ended questions. RESULTS: In Group 1, 44% of the 183 patients did not have an acceptable idea about what glaucoma is, 30% did not know the purpose of the medications they were taking, 47% were not aware of what was an average intraocular pressure, and 45% did not understand why visual fields were examined. In Group 2, 54% gave unsatisfactory answers to the question What is glaucoma?, 54% did not know the purpose of the medications they were taking, 80% were not aware of what was an average intraocular pressure, and 94% did not understand why visual fields were examined (p<0.001). Linear regression analysis demonstrated that level of education was positively correlated to knowledge about glaucoma in both groups (r=0.65, p=0.001). CONCLUSION: This study showed that patients' knowledge about glaucoma varies greatly, and that in an urban, American setting, around one third of the patients have minimal understanding, whereas in an urban setting in Brazil around two thirds of patients were lacking basic information about glaucoma. Innovative and effective methods are needed to correct this situation.
Resumo:
PURPOSE: To evaluate the need for artificial tears by glaucoma patients under topical hypotensive treatment and to identify risk factors associated with it. METHODS: The charts of 175 glaucoma patients under medical treatment and 175 age-matched controls were reviewed. Age, gender, use of artificial tears, number of glaucoma medications used, and duration of treatment were recorded. RESULTS: Significantly more glaucoma patients (n=92; 52.6%) used artificial tears compared to age-matched controls (n=31; 17.7%) (p<0.001). Significantly more females (n=81; 39%) than males (n=42; 28.9%) used artificial tears (p=0.036). When the whole population was analyzed, female gender (OR=1.63) and the presence of glaucoma (OR= 5.14) were risk factors for the use of artificial tears (p<0.05). When the glaucoma population was analyzed, female gender (OR=2.57), number of medications >2 (OR=1.92), and duration of treatment >5 years (OR=2.93) were risk factors for the use of artificial tears (p<0.05). CONCLUSIONS: Topical treatment with antiglaucoma medication is a risk factor for the use of artificial tears. Female gender and long-term treatment of glaucoma with two or more medications were aggravating factors for the need for artificial tears.
Resumo:
PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.
Resumo:
The goal of this cross-sectional observational study was to quantify the pattern-shift visual evoked potentials (VEP) and the thickness as well as the volume of retinal layers using optical coherence tomography (OCT) across a cohort of Parkinson's disease (PD) patients and age-matched controls. Forty-three PD patients and 38 controls were enrolled. All participants underwent a detailed neurological and ophthalmologic evaluation. Idiopathic PD cases were included. Cases with glaucoma or increased intra-ocular pressure were excluded. Patients were assessed by VEP and high-resolution Fourier-domain OCT, which quantified the inner and outer thicknesses of the retinal layers. VEP latencies and the thicknesses of the retinal layers were the main outcome measures. The mean age, with standard deviation (SD), of the PD patients and controls were 63.1 (7.5) and 62.4 (7.2) years, respectively. The patients were predominantly in the initial Hoehn-Yahr (HY) disease stages (34.8% in stage 1 or 1.5, and 55.8 % in stage 2). The VEP latencies and the thicknesses as well as the volumes of the retinal inner and outer layers of the groups were similar. A negative correlation between the retinal thickness and the age was noted in both groups. The thickness of the retinal nerve fibre layer (RNFL) was 102.7 μm in PD patients vs. 104.2 μm in controls. The thicknesses of retinal layers, VEP, and RNFL of PD patients were similar to those of the controls. Despite the use of a representative cohort of PD patients and high-resolution OCT in this study, further studies are required to establish the validity of using OCT and VEP measurements as the anatomic and functional biomarkers for the evaluation of retinal and visual pathways in PD patients.
Resumo:
To evaluate the efficacy and safety of intravitreal bevacizumab (IVB) in eyes with neovascular glaucoma (NVG) undergoing Ahmed glaucoma valve (AGV) implantation. This was a multicentre, prospective, randomized clinical trial that enrolled 40 patients with uncontrolled neovascular glaucoma that had undergone panretinal photocoagulation and required glaucoma drainage device implantation. Patients were randomized to receive IVB (1.25 mg) or not during Ahmed valve implant surgery. Injections were administered intra-operatively, and 4 and 8 weeks after surgery. After a mean follow-up of 2.25 ± 0.67 years (range 1.5-3 years), both groups showed a significant decrease in IOP (p < 0.05). There was no difference in IOP between groups except at the 18-month interval, when IOP in IVB group was significantly lower (14.57 ± 1.72 mmHg vs. 18.37 ± 1.06 mmHg - p = 0.0002). There was no difference in survival success rates between groups. At 24 months, there was a trend to patients treated with IVB using less antiglaucoma medications than the control group (p = 0.0648). Complete regression of rubeosis iridis was significantly more frequent in the IVB group (80%) than in the control group (25%) (p = 0.0015). Intravitreal bevacizumab may lead to regression of new vessels both in the iris and in the anterior chamber angle in patients with neovascular glaucoma undergoing Ahmed glaucoma valve implantation. There is a trend to slightly lower IOPs and number of medications with IVB use during AGV implantation for neovascular glaucoma.
Resumo:
Purpose: To analyze the efficacy and safety of intraope-rative mitomycin C (MMC) in combined procedures (extra-capsular cataract extraction + trabeculectomy). Methods: Twenty-four patients were randomized to either MMC (0.5 mg/ml) (n = 14) or saline solution (n = 10) for 3 minutes during the combined procedure. Results: Twelve months after surgery, mean IOP in the MMC group (13.2 ± 2.9 mmHg) was significantly lower than in the control group (16.3 ± 3.9 mmHg) (p = 0.02). The mean number of medications used during the 12-month follow-up in the control group (1.33 ± 0.5) was significantly higher than in the MMC-treated group (0.5 ± 0.5) (p = 0.005). Life table analysis showed a significantly higher probability of IOP control in the MMC group than in the control group (p < 0.01). Conclusions: Intraoperative MMC is safe and effective in pro-moting a better IOP control and reducing the need for postoperative antiglaucoma medications. We suggest intraope-rative MMC to be routinely employed in combined procedures.
Resumo:
PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.
Resumo:
PURPOSE: To evaluate changes in retinal nerve fiber layer thickness as measured by scanning laser polarimetry (SLP) after the use of medication to reduce intraocular pressure (IOP) in glaucomatous or ocular hypertensive patients. METHODS: The authors prospectively enrolled 37 eyes of 37 patients in whom IOP was reduced by more than 25% after the use of medication. The images were obtained before and 15 to 30 days after the introduction of medication. The SLP parameters measured before and after the use of medication were compared using paired Student's t Test. RESULTS: The mean IOP was significantly reduced from 26.57±4.23 mmHg to 16.54 ±2.92 mmHg after the use of medication (p<0.05). None of the 10 SLP analyzed parameters was significantly affected by the reduction of IOP with medication (p>0.05). CONCLUSION: The retinal nerve fiber layer thickness, as measured by SLP, is not affected by the reduction of IOP with medication in patients with glaucoma or ocular hypertension.
Resumo:
Button battery ingestion is a frequent pediatric complaint. The serious complications resulting from accidental ingestion have increased significantly over the last two decades due to easy access to gadgets and electronic toys. Over recent years, the increasing use of lithium batteries of diameter 20 mm has brought new challenges, because these are more detrimental to the mucosa, compared with other types, with high morbidity and mortality. The clinical complaints, which are often nonspecific, may lead to delayed diagnosis, thereby increasing the risk of severe complications. A five-year-old boy who had been complaining of abdominal pain for ten days, was brought to the emergency service with a clinical condition of hematemesis that started two hours earlier. On admission, he presented pallor, tachycardia and hypotension. A plain abdominal x-ray produced an image suggestive of a button battery. Digestive endoscopy showed a deep ulcerated lesion in the esophagus without active bleeding. After this procedure, the patient presented profuse hematemesis and severe hypotension, followed by cardiorespiratory arrest, which was reversed. He then underwent emergency exploratory laparotomy and presented a new episode of cardiorespiratory arrest, which he did not survive. The battery was removed through rectal exploration. This case describes a fatal evolution of button battery ingestion with late diagnosis and severe associated injury of the digestive mucosa. A high level of clinical suspicion is essential for preventing this evolution. Preventive strategies are required, as well as health education, with warnings to parents, caregivers and healthcare professionals.
Resumo:
The cerebellum is an important site for cortical demyelination in multiple sclerosis, but the functional significance of this finding is not fully understood. To evaluate the clinical and cognitive impact of cerebellar grey-matter pathology in multiple sclerosis patients. Forty-two relapsing-remitting multiple sclerosis patients and 30 controls underwent clinical assessment including the Multiple Sclerosis Functional Composite, Expanded Disability Status Scale (EDSS) and cerebellar functional system (FS) score, and cognitive evaluation, including the Paced Auditory Serial Addition Test (PASAT) and the Symbol-Digit Modalities Test (SDMT). Magnetic resonance imaging was performed with a 3T scanner and variables of interest were: brain white-matter and cortical lesion load, cerebellar intracortical and leukocortical lesion volumes, and brain cortical and cerebellar white-matter and grey-matter volumes. After multivariate analysis high burden of cerebellar intracortical lesions was the only predictor for the EDSS (p<0.001), cerebellar FS (p = 0.002), arm function (p = 0.049), and for leg function (p<0.001). Patients with high burden of cerebellar leukocortical lesions had lower PASAT scores (p = 0.013), while patients with greater volumes of cerebellar intracortical lesions had worse SDMT scores (p = 0.015). Cerebellar grey-matter pathology is widely present and contributes to clinical dysfunction in relapsing-remitting multiple sclerosis patients, independently of brain grey-matter damage.
Resumo:
Bone marrow is organized in specialized microenvironments known as 'marrow niches'. These are important for the maintenance of stem cells and their hematopoietic progenitors whose homeostasis also depends on other cell types present in the tissue. Extrinsic factors, such as infection and inflammatory states, may affect this system by causing cytokine dysregulation (imbalance in cytokine production) and changes in cell proliferation and self-renewal rates, and may also induce changes in the metabolism and cell cycle. Known to relate to chronic inflammation, obesity is responsible for systemic changes that are best studied in the cardiovascular system. Little is known regarding the changes in the hematopoietic system induced by the inflammatory state carried by obesity or the cell and molecular mechanisms involved. The understanding of the biological behavior of hematopoietic stem cells under obesity-induced chronic inflammation could help elucidate the pathophysiological mechanisms involved in other inflammatory processes, such as neoplastic diseases and bone marrow failure syndromes.