3 resultados para Field programmable gate arrays (FPGA)

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very high field (29)Si-NMR measurements using a fully (29)Si-enriched URu(2)Si(2) single crystal were carried out in order to microscopically investigate the hidden order (HO) state and adjacent magnetic phases in the high field limit. At the lowest measured temperature of 0.4 K, a clear anomaly reflecting a Fermi surface instability near 22 T inside the HO state is detected by the (29)Si shift, (29)K(c). Moreover, a strong enhancement of (29)K(c) develops near a critical field H(c) ≃ 35.6 T, and the ^{29}Si-NMR signal disappears suddenly at H(c), indicating the total suppression of the HO state. Nevertheless, a weak and shifted (29)Si-NMR signal reappears for fields higher than H(c) at 4.2 K, providing evidence for a magnetic structure within the magnetic phase caused by the Ising-type anisotropy of the uranium ordered moments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local parity-odd domains are theorized to form inside a quark-gluon plasma which has been produced in high-energy heavy-ion collisions. The local parity-odd domains manifest themselves as charge separation along the magnetic field axis via the chiral magnetic effect. The experimental observation of charge separation has previously been reported for heavy-ion collisions at the top RHIC energies. In this Letter, we present the results of the beam-energy dependence of the charge correlations in Au+Au collisions at midrapidity for center-of-mass energies of 7.7, 11.5, 19.6, 27, 39, and 62.4 GeV from the STAR experiment. After background subtraction, the signal gradually reduces with decreased beam energy and tends to vanish by 7.7 GeV. This implies the dominance of hadronic interactions over partonic ones at lower collision energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

cDNA arrays are a powerful tool for discovering gene expression patterns. Nylon arrays have the advantage that they can be re-used several times. A key issue in high throughput gene expression analysis is sensitivity. In the case of nylon arrays, signal detection can be affected by the plastic bags used to keep membranes humid. In this study, we evaluated the effect of five types of plastics on the radioactive transmittance, number of genes with a signal above the background, and data variability. A polyethylene plastic bag 69 μm thick had a strong shielding effect that blocked 68.7% of the radioactive signal. The shielding effect on transmittance decreased the number of detected genes and increased the data variability. Other plastics which were thinner gave better results. Although plastics made from polyvinylidene chloride, polyvinyl chloride (both 13 μm thick) and polyethylene (29 and 7 μm thick) showed different levels of transmittance, they all gave similarly good performances. Polyvinylidene chloride and polyethylene 29 mm thick were the plastics of choice because of their easy handling. For other types of plastics, it is advisable to run a simple check on their performance in order to obtain the maximum information from nylon cDNA arrays.