10 resultados para Eye pattern

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although cartilaginous tumors have low microvascular density, vessels are important for the provision of nutrition so that the tumor can grow and generate metastasis. The aim of this study was to assess the value of the vascular pattern classification as a prognostic tool in chondrosarcomas (CSs) and its relation with vascular endothelial growth factor (VEGF) expression. This was a retrospective study of 21 enchondromas and 57 conventional CSs. Clinical data and outcome were retrieved from medical files. CSs histologic grades (on a scale of 1 to 3) were determined according to the World Health Organization classification. The vascular pattern (on a scale of A to C) was assessed through CD34, according to Kalinski. CD105 and VEGF were also evaluated. Poor outcome was significantly associated with vascular pattern groups B and C. Higher vascular pattern were 6.5 times more frequent in moderate-grade and high-grade CSs than in grade 1 CS. On multivariate analysis, a clear correlation was found between VEGF overexpression and B/C vascular patterns. Only 18 (benign and malignant) tumors stained for CD105. The results point to the use of the vascular pattern classification as a prognostic tool in CSs and to differentiate low-grade from moderate-grade/high-grade CSs. Vascular pattern might be also used to complement histologic grade, VEGF immunostaining, and microvascular density, for indicating a patient's prognosis. Low-grade CSs develop under low neoangiogenesis, which conforms to the slow growth rate of these tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the remarkable improvements in breast cancer (BC) characterization, accurate prediction of BC clinical behavior is often still difficult to achieve. Some studies have investigated the association between the molecular subtype, namely the basal-like BC and the pattern of relapse, however only few investigated the association between relapse pattern and immunohistochemical defined triple-negative breast cancers (TNBCs). The aim of this study was to evaluate the pattern of relapse in patients with TNBC, namely the primary distant relapse site. One-hundred twenty nine (129) invasive breast carcinomas with follow-up information were classified according to the molecular subtype using immunohistochemistry for ER, PgR and Her2. The association between TNBC and distant relapse primary site was analyzed by logistic regression. Using multivariate logistic regression analysis patients with TNBC displayed only 0.09 (95% CI: 0.00-0.74; p=0.02) the odds of the non-TNBC patients of developing bone primary relapse. Regarding visceral and lymph-node relapse, no differences between in this cohort were found. Though classically regarded as aggressive tumors, TNBCs rarely development primary relapse in bone when compared to non-TNBC, a clinical relevant fact when investigating a metastasis of an occult or non-sampled primary BC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this cephalometric study was to evaluate the influence of the sagittal skeletal pattern on the 'Y-axis of growth' measurement in patients with different malocclusions. Lateral head films from 59 patients (mean age 16y 7m, ranging from 11 to 25 years) were selected after a subjective analysis of 1630 cases. Sample was grouped as follows: Group 1 - class I facial pattern; group 2 - class II facial pattern; and Group 3 - class III facial pattern. Two angular measurements, SNGoGn and SNGn, were taken in order to determine skeletal vertical facial pattern. A logistic regression with errors distributed according to a binomial distribution was used to test the influence of the sagittal relationship (Class I, II, III facial patterns) on vertical diagnostic measurement congruence (SNGoGn and SNGn). RESULTS show that the probability of congruence between the patterns SNGn and SNGoGn was relatively high (70%) for group 1, but for groups II (46%) and III (37%) this congruence was relatively low. The use of SNGn appears to be inappropriate to determine the vertical facial skeletal pattern of patients, due to Gn point shifting throughout sagittal discrepancies. Clinical Significance: Facial pattern determined by SNGn must be considered carefully, especially when severe sagittal discrepancies are present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chronic telogen effluvium (CTE), a poorly understood condition, can be confused with or may be a prodrome to female pattern hair loss (FPHL). The pathogenesis of both is related to follicle cycle shortening and possibly to blood supply changes. To analyze a number of histomorphometric and immunohistochemical findings through vascular endothelial growth factor (VEGF), Ki-67, and CD31 immunostaining in scalp biopsies of 20 patients with CTE, 17 patients with mild FPHL and 9 controls. Ki-67 index and VEGF optical density were analyzed at the follicular outer sheath using ImageJ software. CD31 microvessel density was assessed by a Chalkley grid. Significant follicle miniaturization and higher density of nonanagen follicles were found in FPHL, compared with patients with CTE and controls. Ki-67+ index correlated positively with FPHL histological features. The FPHL group showed the highest VEGF optical density, followed by the CTE and control groups. No differences were found in CD31 microvessel density between the three groups. Histomorphometric results establish CTE as a distinct disorder, separate from FPHL from its outset. Its pathogenic mechanisms are also distinct. These findings support the proposed mechanism of 'immediate telogen release' for CTE, leading to cycle synchronization. For FPHL, accelerated anagen follicular mitotic rates and, thus, higher Ki-67 and VEGF values, would leave less time for differentiation, resulting in hair miniaturization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

36

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seasonally dry tropical plant formations (SDTF) are likely to exhibit phylogenetic clustering owing to niche conservatism driven by a strong environmental filter (water stress), but heterogeneous edaphic environments and life histories may result in heterogeneity in degree of phylogenetic clustering. We investigated phylogenetic patterns across ecological gradients related to water availability (edaphic environment and climate) in the Caatinga, a SDTF in Brazil. Caatinga is characterized by semiarid climate and three distinct edaphic environments - sedimentary, crystalline, and inselberg -representing a decreasing gradient in soil water availability. We used two measures of phylogenetic diversity: Net Relatedness Index based on the entire phylogeny among species present in a site, reflecting long-term diversification; and Nearest Taxon Index based on the tips of the phylogeny, reflecting more recent diversification. We also evaluated woody species in contrast to herbaceous species. The main climatic variable influencing phylogenetic pattern was precipitation in the driest quarter, particularly for herbaceous species, suggesting that environmental filtering related to minimal periods of precipitation is an important driver of Caatinga biodiversity, as one might expect for a SDTF. Woody species tended to show phylogenetic clustering whereas herbaceous species tended towards phylogenetic overdispersion. We also found phylogenetic clustering in two edaphic environments (sedimentary and crystalline) in contrast to phylogenetic overdispersion in the third (inselberg). We conclude that while niche conservatism is evident in phylogenetic clustering in the Caatinga, this is not a universal pattern likely due to heterogeneity in the degree of realized environmental filtering across edaphic environments. Thus, SDTF, in spite of a strong shared environmental filter, are potentially heterogeneous in phylogenetic structuring. Our results support the need for scientifically informed conservation strategies in the Caatinga and other SDTF regions that have not previously been prioritized for conservation in order to take into account this heterogeneity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To study the effects of pupillary constriction on frequency doubling perimetry in a group of normal subjects. Methods: Eighteen healthy volunteers participated in the study. Only one eye per patient (right eye) underwent frequency doubling perimetry (Full Threshold C-20 strategy). For the second session, one drop of 2% pilocarpine was administered to the volunteers' right eye and the examination was repeated after 60 minutes. Results: Sixty minutes after administration of 2% pilocarpine, there was a significant reduction of the pupillary diameter from 4.22 ± 0.17 mm to 1.55 ± 0.51 mm (p<0.05). There was a significant reduction of the mean retinal sensibility after pupillary constriction. The threshold sensitivity of the central 5º worsened by 5.67 ± 2.49 dB; the area between 2.5º and 10º worsened by 4.49 ± 2.73 dB; and the area between 10º and 20º worsened by 5.10 ± 3.55 dB (p<0.01). A reduction of 4.06 ± 2.67 dB was observed in the mean deviation, as well as an increase of 0.64 ± 0.94 dB in the pattern standard deviation (p<0.01). No differences were observed regarding the number of fixation losses, false-positive and false-negatives responses, and duration of the examination. Conclusion: Changes in pupillary diameter may produce significant declines in threshold sensitivities of the 20º visual field tested by frequency doubling perimetry. These results suggest that is important to maintain a constant pupillary diameter in seriate examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dry eye disease and ocular surface disorders may be caused or worsened by viral agents. There are several known and suspected virus associated to ocular surface diseases. The possible pathogenic mechanisms for virus-related dry eye disease are presented herein. This review serves to reinforce the importance of ophthalmologists as one of the healthcare professional able to diagnose a potentially large number of infected patients with high prevalent viral agents.