22 resultados para Exames tomográficos pediátricos
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
The authors present the analysis of 27 computed tomography scans (CT) of 18 children which were divided in three groups according to clinical and tomographic criteria. Group 1 was characterized mainly by epilepsy and calcifications. Group 2 was characterized by intracranial hypertension and several tomographic aspects: edema, cysts and nodules were seen in three patients; hydrocephaly and calcifications were seen in two patients and CT was normal in one patient. Group 3 had patients with epilepsy or headache and variable tomographic patterns. The results are discussed based on the available literature.
Resumo:
We studied the clinical aspects of 100 consecutive premature newborns with and without intraventricular and periventricular hemorrhage (IPVH).The diagnosis of IPVH was obtained by ultrasonic scans of the skull during the first week of life and at the age of one month. Forty eight percent of newborns with IPVH had abnormal results, and there was a significant correlation with the neurological evaluation in 85% of the infants. The probability of normality for a child with no associated brain abnormalities was 72%, whereas for a child of the same gestational age with associated brain abnormalities was 48.7%.
Resumo:
Moyamoya is a chronic progressive cerebrovascular disease with characteristic angiographic findings and a clinical picture with episodes of transient ischemic attacks, headache, seizures, hemiparesis, which may resolve after surgical treatment. We describe the case of a girl with the typical findings of the disease, comparing them before and after surgery with the use of neuropsychological tests, neurological examination and laboratory tests.
Resumo:
OBJECTIVE: To describe the role of magnetic resonance imaging (MRI) in the evaluation of patients with chronic and recurrent aseptic meningitis.METHOD: A retrospective study of five patients with aseptic meningoencefalitis diagnosed by clinical and CSF findings. CT scans showed without no relevant findings. RESULTS: MRI showed small multifocal lesions hyperintense on T2 weighted images and FLAIR, with mild or no gadolinium enhancement, mainly in periventricular and subcortical regions. Meningoencephalitis preceded the diagnosis of the underlying disease in four patients (Behçet´s disease or systemic lupus erythematosus). After the introduction of adequate treatment for the rheumatic disease, they did not present further symptoms of aseptic meningoencephalitis. CONCLUSION: Aseptic meningoencephalitis can be an early presentation of an autoimmune disease. It is important to emphasize the role of MRI in the diagnosis and follow-up of these patients.
Resumo:
The chronic treatment with phenytoin or the acute intoxication by this drug may cause permanent cerebellar injury with atrophy of cerebellum vermis and hemispheres, which can be detected by neuroimaging studies. The aim of the present study was to investigate the correlation between the dosage and duration of treatment with phenytoin and the occurrence of cerebellar atrophy. Sixty-six patients were studied and had their tomographies analyzed for cerebellar atrophy. Of the 66 patients studied, 18 had moderate/severe atrophy, 15 had mild atrophy and 33 were considered to be normal. The patients with moderate/severe atrophy were those with higher exposure to phenytoin (longer duration of treatment and higher total dosage) showing statistically significant difference when compared to patients with mild atrophy or without atrophy (p=0.02). Further, the patients with moderate/severe atrophy had serum levels of phenytoin statistically higher than those of patients with mild atrophy or without atrophy (p = 0.008). There was no association between other antiepileptic drugs dosage or duration of treatment and degree of cerebellar atrophy. We also found that older patients had cerebellar atrophy more frequently, indicating that age or duration of the seizure disorder may also be important in the determination of cerebellar degeneration in these patients. We conclude that although there is a possibility that repeated seizures contribute to cerebellar damage, long term exposure to phenytoin, particularly in high doses and toxic serum levels, cause cerebellar atrophy.
Resumo:
This study evaluated two cases of Apert's syndrome, through phonological, cognitive, and neuropsychological instruments and correlated the results to complementary exams. In short, this study reveals the necessity of application of neuropsychological, cognitive and phonological evaluation and correlation of the results with complementary testings because significant differences can be present in the Apert's syndrome.
Resumo:
The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.
Resumo:
OBJECTIVE: To evaluate the positive predictive value for BI-RADS (Breast Imaging Reporting and Data System) categories 3, 4 and 5, correlating mammographic and histological diagnosis in non-palpable breast lesions. MATERIALS AND METHODS: Analytical-descriptive study of 169 women submitted to stereotactic localization for surgical biopsy of non-palpable breast lesions. Mammographic and histological findings were correlated, analyzing the predictive positive value for each category. RESULTS: Forty-two (24.8%) cases were diagnosed with breast cancer - only one in category 3, 19 in category 4, and 22 in category 5. The positive predictive value for categories 3, 4A, 4B, 4C and 5 were, respectively, 3.4%, 10.3%, 11.3%, 36% and 91.7%. Microcalcifications were the most frequent finding related to malignancy, present in 61.5% of these cases. CONCLUSION: The present study has demonstrated that BI-RADS allows a safe prediction of high suspicion of malignancy in lesions category 5 and low suspicion for category 3. As regards the category 4, the positive predictive value has shown a progressive increase in subcategories A, B and C, demonstrating that this subclassification represents an invaluable contribution for a more detailed and accurate assessment of lesions suspicious for malignancy.
Resumo:
Laboratory tests are essential for accurate diagnosis and cost-effective management of thyroid disorders. When the clinical suspicion is strong, hormonal levels just confirms the diagnosis. However, in most patients, symptoms are subtle and unspecific, so that only biochemical tests can detect the disorder. The objective of this article is to do a critical analysis of the appropriate use of the most important thyroid function tests, including serum concentrations of thyrotropin (TSH), thyroid hormones and antithyroid antibodies. Through a survey in the MedLine database, we discuss the major pitfalls and interferences related to daily use of these tests and recommendations are presented to optimize the use of these diagnostic tools in clinical practice.
Resumo:
Purpose: To analyze the effects of 100 mg of sildenafil citrate (Viagra®) on the retrobulbar circulation and visual field. Methods: A double masked, placebo controlled study was conducted in 10 males with a mean age of 27.7 + 5.68 years. The right eye of each volunteer underwent orbital color Doppler imaging and automated perimetry (Humphrey, program 30-2, Full-Threshold Strategy) at 3 occasions: baseline, 1 hour after placebo and 1 hour after 100 mg of sildenafil. The foveal threshold and the mean deviation (MD) were analyzed by automated perimetry on the three occasions. Color Doppler imaging allowed the measurement of the peak systolic velocity (PSV), end diastolic velocity (EDV) and Pourcelot index (PI) in the central retinal artery and ophthalmic artery. Results: The foveal threshold and the mean deviation did not show a significant change following the administration of sildenafil. The ophthalmic artery peak systolic velocity and end diastolic velocity significantly increased after the administration of sildenafil (p<0.001). The hemodynamic parameters in the central retinal artery and the ophthalmic artery PI did not significantly change. Conclusions: Sildefanil citrate increased the blood flow velocities in the ophthalmic artery in normal subjects, with no significant changes in the foveal threshold and mean deviation in the automated perimetry.
Resumo:
Purpose: To study the effects of pupillary constriction on frequency doubling perimetry in a group of normal subjects. Methods: Eighteen healthy volunteers participated in the study. Only one eye per patient (right eye) underwent frequency doubling perimetry (Full Threshold C-20 strategy). For the second session, one drop of 2% pilocarpine was administered to the volunteers' right eye and the examination was repeated after 60 minutes. Results: Sixty minutes after administration of 2% pilocarpine, there was a significant reduction of the pupillary diameter from 4.22 ± 0.17 mm to 1.55 ± 0.51 mm (p<0.05). There was a significant reduction of the mean retinal sensibility after pupillary constriction. The threshold sensitivity of the central 5º worsened by 5.67 ± 2.49 dB; the area between 2.5º and 10º worsened by 4.49 ± 2.73 dB; and the area between 10º and 20º worsened by 5.10 ± 3.55 dB (p<0.01). A reduction of 4.06 ± 2.67 dB was observed in the mean deviation, as well as an increase of 0.64 ± 0.94 dB in the pattern standard deviation (p<0.01). No differences were observed regarding the number of fixation losses, false-positive and false-negatives responses, and duration of the examination. Conclusion: Changes in pupillary diameter may produce significant declines in threshold sensitivities of the 20º visual field tested by frequency doubling perimetry. These results suggest that is important to maintain a constant pupillary diameter in seriate examinations.
Resumo:
PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.
Resumo:
PURPOSE: To determine the mean critical fusion frequency and the short-term fluctuation, to analyze the influence of age, gender, and the learning effect in healthy subjects undergoing flicker perimetry. METHODS: Study 1 - 95 healthy subjects underwent flicker perimetry once in one eye. Mean critical fusion frequency values were compared between genders, and the influence of age was evaluated using linear regression analysis. Study 2 - 20 healthy subjects underwent flicker perimetry 5 times in one eye. The first 3 sessions were separated by an interval of 1 to 30 days, whereas the last 3 sessions were performed within the same day. The first 3 sessions were used to investigate the presence of a learning effect, whereas the last 3 tests were used to calculate short-term fluctuation. RESULTS: Study 1 - Linear regression analysis demonstrated that mean global, foveal, central, and critical fusion frequency per quadrant significantly decreased with age (p<0.05).There were no statistically significant differences in mean critical fusion frequency values between males and females (p>0.05), with the exception of the central area and inferonasal quadrant (p=0.049 and p=0.011, respectively), where the values were lower in females. Study 2 - Mean global (p=0.014), central (p=0.008), and peripheral (p=0.03) critical fusion frequency were significantly lower in the first session compared to the second and third sessions. The mean global short-term fluctuation was 5.06±1.13 Hz, the mean interindividual and intraindividual variabilities were 11.2±2.8% and 6.4±1.5%, respectively. CONCLUSION: This study suggests that, in healthy subjects, critical fusion frequency decreases with age, that flicker perimetry is associated with a learning effect, and that a moderately high short-term fluctuation is expected.
Resumo:
PURPOSE: To report a case of Nocardia asteroides scleritis in a patient without risk factors for infeccious scleritis. METHODS: A 38-year old woman was initially examined for pain, discharge, photophobia of 1 month duration in her right eye. Her medical and ophthalmological history were unremarkable. The results of laboratory tests were normal. Surgical debridement of necrotic tissue was performed and material was sent for biopsy and culture confirmed as Nocardia asteroides. Treatment consisted of amikacin eyedrops, and systemic trimethropim-sulfamethoxazole. The infection resolved leaving scleral thinning and a subconjunctival fibrovascular scar. Best corrected visual acuity two months after referral had improved to LE, 20/20. CONCLUSION: Prompt evaluation and treatment is essential for successful management of Nocardia asteroides infectious scleritis.
Resumo:
OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.