3 resultados para EFFECTIVE REGURGITANT ORIFICE

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

β-Carotene, zeaxanthin, lutein, β-cryptoxanthin, and lycopene are liposoluble pigments widely distributed in vegetables and fruits and, after ingestion, these compounds are usually detected in human blood plasma. In this study, we evaluated their potential to inhibit hemolysis of human erythrocytes, as mediated by the toxicity of peroxyl radicals (ROO•). Thus, 2,2'-azobis (2-methylpropionamidine) dihydrochloride (AAPH) was used as ROO• generator and the hemolysis assay was carried out in experimental conditions optimized by response surface methodology, and successfully adapted to microplate assay. The optimized conditions were verified at 30 × 10(6) cells/mL, 17 mM of AAPH for 3 h, at which 48 ± 5% of hemolysis was achieved in freshly isolated erythrocytes. Among the tested carotenoids, lycopene (IC(50) = 0.24 ± 0.05 μM) was the most efficient to prevent the hemolysis, followed by β-carotene (0.32 ± 0.02 μM), lutein (0.38 ± 0.02 μM), and zeaxanthin (0.43 ± 0.02 μM). These carotenoids were at least 5 times more effective than quercetin, trolox, and ascorbic acid (positive controls). β-Cryptoxanthin did not present any erythroprotective effect, but rather induced a hemolytic effect at the highest tested concentration (3 μM). These results suggest that selected carotenoids may have potential to act as important erythroprotective agents by preventing ROO•-induced toxicity in human erythrocytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdution: The transcatheter aortic valve implantation in the treatment of high-risk symptomatic aortic stenosis has increased the number of implants every year. The learning curve for transcatheter aortic valve implantation has improved since the last 12 years, allowing access alternatives. The aim of this study is to approach the implantation of transcatheter aortic valve through transaortic via associated with off-pump cardiopulmonary bypass surgery in a 67-year-old man, with chronic obstructive pulmonary disease, arterial hypertension and kidney transplant. Off-pump coronary artery bypass surgery was performed and the valve in the aortic position was released successfully. There were no complications in the intraoperative and postoperative period. Gradient reduction, effective orifice increasing of the prosthesis and absence of valvular regurgitation after implantation were observed by transesophageal echocardiography. Procedural success demonstrates that implantation of transcatheter aortic valve through the ascending aorta associated with coronary artery bypass surgery without CPB is a new option for these patients.