2 resultados para CO-MORBIDITIES

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed to describe the distribution of waist-to-height ratio (WHtR) percentiles and cutoffs for obesity in Brazilian adolescents. A cross-sectional study including adolescents aged 10 to 15 years was conducted in the city of São Paulo, Brazil; anthropometric measurements (weight, height, and waist-circumference) were taken, and WHtRs were calculated and then divided into percentiles derived by using Least Median of Squares (LMS) regression. The receiver operating characteristic (ROC) curve was used in determining cutoffs for obesity (BMI ≥ 97th percentile) and Mann-Whitney and Kruskal-Wallis tests were used for comparing variables. The study included 8,019 adolescents from 43 schools, of whom 54.5% were female, and 74.8% attended public schools. Boys had higher mean WHtR than girls (0.45 ± 0.06 vs 0.44 ± 0.05; p=0.002) and higher WHtR at the 95th percentile (0.56 vs 0.54; p<0.05). The WHtR cutoffs according to the WHO criteria ranged from 0.467 to 0.506 and 0.463 to 0.496 among girls and boys respectively, with high sensitivity (82.8-95%) and specificity (84-95.5%). The WHtR was significantly associated with body adiposity measured by BMI. Its age-specific percentiles and cutoffs may be used as additional surrogate markers of central obesity and its co-morbidities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction