11 resultados para Brand’s positioning

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Harmony is one of the main objectives in surgical and orthodontic treatment and this harmony must be present in the smile, as well as in the face. The aim of the present study was to assess the perceptions of professionals and laypersons in relation to the harmony of the smile of patients with or without vertical maxillary alterations. Sixty observers (oral and maxillofacial surgeons, orthodontists and laypersons) reported the degree of harmony of six smiles using an objective questionnaire and the participants indicated if there was a need for corrective surgery or not. The classification of observers was recorded on a Likert scale from 1 to 5. Mixed regression was used to determine differences between the three groups. Statistically significant differences were found only for the harmony of the smile between the oral and maxillofacial surgeons and laypersons, with laypersons being more critical when assessing the smile. There was no statistical difference between the other groups for the harmony of the smile or the indication of corrective surgery. The patterns of greater or lesser harmony determined by observers during the smile were similar to those found in the literature as the ideal standard in relation to vertical maxillary positioning. Laypersons had a tendency to be more critical in relation to facial harmony than surgeons, although no statistical differences were found in the other groups in relation to the harmony of the smile or indication for the corrective surgery. In addition, the patterns of greater or lesser harmony of the smile determined by the participants were similar to those found in the literature as the ideal standard in relation to vertical maxillary positioning. Overall, the present study demonstrates that adequate interaction between surgeons, orthodontists and laypersons is essential in order to achieve facial harmony with orthodontic and/or surgical treatment. Opinion of specialists and laypersons about the smile in relation to the vertical positioning of the maxilla.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flavanones (hesperidin, naringenin, naringin, and poncirin) in industrial, hand-squeezed orange juices and from fresh-in-squeeze machines orange juices were determined by HPLC/DAD analysis using a previously described liquid-liquid extraction method. Method validation including the accuracy was performed by using recovery tests. Samples (36) collected from different Brazilian locations and brands were analyzed. Concentrations were determined using an external standard curve. The limits of detection (LOD) and the limits of quantification (LOQ) calculated were 0.0037, 1.87, 0.0147, and 0.0066 mg 100 g(-1) and 0.0089, 7.84, 0.0302, and 0.0200 mg 100 g(-1) for naringin, hesperidin, poncirin, and naringenin, respectively. The results demonstrated that hesperidin was present at the highest concentration levels, especially in the industrial orange juices. Its average content and concentration range were 69.85 and 18.80-139.00 mg 100 g(-1). The other flavanones showed the lowest concentration levels. The average contents and concentration ranges found were 0.019, 0.01-0.30, and 0.12 and 0.1-0.17, 0.13, and 0.01-0.36 mg 100 g(-1), respectively. The results were also evaluated using the principal component analysis (PCA) multivariate analysis technique which showed that poncirin, naringenin, and naringin were the principal elements that contributed to the variability in the sample concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of cisplatin can induce type I hypersensitivity reactions that may also be linked to the quality of the drug utilized. We observed cases of hypersensitivity that appeared to be associated with the brand of cisplatin used. The aim of this study was to compare two different brands of cisplatin in relation to type I hypersensitivity reactions. Brand A was used in a tertiary care teaching hospital until 2012, and use of brand B started from January 2013, when the first hypersensitivity cases were observed. Patients were categorized based on symptom. Cisplatin of both brands was analysed by high-performance liquid chromatography (HPLC) and high-resolution electrospray ionization mass spectrometry (ESI-(+)-MS) and characterized according to US Pharmacopeia. There were no cases of hypersensitivity associated with the use of cisplatin brand A, whereas four of 127 outpatients that used cisplatin brand B were affected. The two brands were in accordance with the US Pharmacopeia parameters, and there was no significant difference in the total platinum levels between the two brands when analysed by HPLC. However, high-resolution ESI-(+)-MS analyses show that brand B contains approximately 2.7 times more hydrolysed cisplatin than brand A. The increase in the hydrolysed form of cisplatin found in brand B may be the cause of the hypersensitivity reaction observed in a subset of patients. We present the first study of the quality of drugs by high-resolution ESI-(+)-MS. Drug regulatory agencies and manufacturers should consider including measurement of hydrolysed cisplatin as a quality criterion for cisplatin formulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research was to determine the levels of enrichment of vitamins B1, B2, B6 and B3 in different types and brands of enriched cookies. The chromatographic separation was performed in a C18 column with gradient elution and UV detection at 254 and 287 nm. The results show that only 5 of the 24 brands evaluated are in accordance with the Brazilian legislation with respect to the vitamin content declared on the labels. However, consumption of approximately 100-150 g of most of the brands supplies the recommended dietary intake for children and adults of the vitamins evaluated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Different brands and batches of brazilian regular and instant coffee were purchased in supermarkets of Campinas? city and analysed for caffeine content. The method used involved extraction with boiling water, clarification with saturated basic acetate and determination by high performance liquid cromatography. Analysis was carried out using a Model 6000 A solvent delivery system (Waters associates), and a Model 7125 sample injector system (Reodyne, Inc.) with a 5µl sample loop. The system was also equipped with a Waters Model M440 absorbance detector set at 254 nm. A Merck ODS 5µm column (15 cm x 4.6 mm i.d.) was used to separate the caffeine. The mobile phase was methanol:water (25:75, v/v). The caffeine content varied for different brands and types of coffee and according to the beverage preparation technique. Values in the range of 0.43 to 0.85 mg/ml and 0.61 to 0.82 mg/ml were determined in regular and instant coffee, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brazilian regulations prohibit the addition of cocoa butter replacements to chocolate, in total or partial substitution. The objective of the present work was to check the quality standards of four of coating bitter Brasilian chocolate bars and five of coating milk chocolate bars, commercialized in Campinas. In order to check the possible addition of substitutes, the triacylglycerol composition was determined, and the results were analysed by Padley & Timms mathematical method. The triacylglycerol composition of each sample was determined by high temperature gas chromatography (HTGC). The presence of cocoa butter replacements was not detected in the brands of coating chocolate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Polycyclic aromatic hydrocarbons (PAHs) are a group of compounds that have been the subject of much concern due to their toxic potential. In this study, margarine?s, vegetable cream and mayonnaise available on the Brazilian market were analyzed for pyrene, chrysene, benzo(a)pyrene, benzo(b)fluoranthene and dibenzo(a,h)anthracene. The analytical methodology involved liquid-liquid extraction, clean-up on silica gel column and determination by high performance liquid chromatography using fluorescence detector. Variable levels of contamination were found within differents brands of the same product and within differents batches of the same brand. The total PAH content was in the range of 4.1 to 7.1mug/kg in vegetable cream, 1.7 to 3.9mug/kg in margarine and 1.0 to 21.7mug/kg in mayonnaise. In general the products which according to the label contain corn oil showed the highest levels of contamination. Based on these results and on the importance of fat, oils and derived products for the intake of PAHs, it is recommended that producers of margarine, vegetable creams and mayonnaise start to control the contamination of the vegetable oils used in the elaboration of these products, in order to reduce the exposure of consumers to excessive amounts of potentially carcinogenic compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física