2 resultados para BE
em Repositório da Produção Científica e Intelectual da Unicamp
Resumo:
Parenteral nutrition (PN) formulations are commonly individualized, since their standardization seem inadequate for the pediatric population. This study aimed to evaluate the nutritional state and the reasons for PN individualization in pediatric patients using PN hospitalized in a tertiary hospital in Campinas, São Paulo. This longitudinal study comprised patients using PN followed by up to 67 days. Nutritional status was classified according to the criteria established by the World Health Organization (WHO) (2006) and WHO (2007). The levels of the following elements on blood were analyzed: sodium, potassium, ionized calcium, chloride, magnesium, inorganic phosphorus and triglycerides (TGL). Among the criteria for individualization, were considered undeniable: significant reduction in blood levels of potassium (<3 mEq/L), sodium (<125 mEq/)L, magnesium (<1 mEq/L), phosphorus (<1.5 mEq/L), ionic calcium (<1 mmol) and chloride (<90 mEq/L) or any value above the references. Twelve pediatric patients aged 1 month to 15 years were studied (49 individualizations). Most patients were classified as malnourished. It was observed that 74/254 (29.2%) of examinations demanded individualized PN by indubitable reasons. The nutritional state of patients was considered critical in most cases. Thus, the individualization performed in the beginning of PN for energy protein adequacy was indispensable. In addition, the individualized PN was indispensable in at least 29.2% of PN for correction of alterations found in biochemical parameters.
Resumo:
In this work, the energy response functions of a CdTe detector were obtained by Monte Carlo (MC) simulation in the energy range from 5 to 160keV, using the PENELOPE code. In the response calculations the carrier transport features and the detector resolution were included. The computed energy response function was validated through comparison with experimental results obtained with (241)Am and (152)Eu sources. In order to investigate the influence of the correction by the detector response at diagnostic energy range, x-ray spectra were measured using a CdTe detector (model XR-100T, Amptek), and then corrected by the energy response of the detector using the stripping procedure. Results showed that the CdTe exhibits good energy response at low energies (below 40keV), showing only small distortions on the measured spectra. For energies below about 80keV, the contribution of the escape of Cd- and Te-K x-rays produce significant distortions on the measured x-ray spectra. For higher energies, the most important correction is the detector efficiency and the carrier trapping effects. The results showed that, after correction by the energy response, the measured spectra are in good agreement with those provided by a theoretical model of the literature. Finally, our results showed that the detailed knowledge of the response function and a proper correction procedure are fundamental for achieving more accurate spectra from which quality parameters (i.e., half-value layer and homogeneity coefficient) can be determined.