2 resultados para 3-level System

em Repositório da Produção Científica e Intelectual da Unicamp


Relevância:

40.00% 40.00%

Publicador:

Resumo:

To identify the adherence rate of a statin treatment and possible related factors in female users from the Unified Health System. Seventy-one women were evaluated (64.2 ± 11.0 years) regarding the socio-economic level, comorbidities, current medications, level of physical activity, self-report of muscular pain, adherence to the medical prescription, body composition and biochemical profile. The data were analyzed as frequencies, Chi-Squared test, and Mann Whitney test (p<0.05). 15.5% of women did not adhere to the medical prescription for the statin treatment, whose had less comorbidities (p=0.01), consumed less quantities of medications (p=0.00), and tended to be younger (p=0.06). Those patients also presented higher values of lipid profile (CT: p=0.01; LDL-c: p=0.02). Musculoskeletal complains were not associated to the adherence rate to the medication. The associated factors to adherence of dyslipidemic women to statin medical prescription were age, quantity of comorbidities and quantity of current medication.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.