53 resultados para Leonardo de Argensola, Bartolomé, 1562-1631.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To adapted the critical velocity (CV), RAST test and lactate minimum (LM) to evaluation of female basketball players. METHODS: Twelve well-trained female basketball players (19 ± 1yrs) were submitted to four intensities running (10 - 14 km/h) at shuttle exercise until exhaustion, applied on alternate days. The linear model 'velocity vs. 1/tlim' was adopted to determine the aerobic (CV) and anaerobic (CCA) parameters. The lactate minimum test consisted of two phases: 1) hiperlactatemia induction using the RAST test and 2) incremental test composed by five shuttle run (20-m) at 7, 8, 9, 10, and 12 km/h. Blood samples were collected at the end of each stage. RESULTS: The velocity (vLM) and blood lactate concentration at LM were obtained by two polynomial adjustments: lactate vs. intensity (LM1) and lactate vs. time (LM2). ANOVA one-way, Student t-test and Pearson correlation were used for statistical analysis. The CV was obtained at 10.3 ± 0.2 km/h and the CCA estimated at 73.0 ± 3.4 m. The RAST was capable to induce the hiperlactatemia and to determine the Pmax (3.6 ± 0.2 W/kg), Pmed (2.8 ± 0.1 W/kg), Pmin (2.3 ± 0.1 W/kg) and FI (30 ± 3%). The vLM1 and vLM2 were obtained, respectively, at 9.47 ±0.13 km/h and 9.8 ± 0.13 km/h, and CV was higher than vLM1. CONCLUSION: The results suggest that the non-invasive model can be used to determine the aerobic and anaerobic parameters. Furthermore, the LM test adapted to basketball using RAST and progressive phase was effective to evaluate female athletes considering the specificity of modality, with high success rates observed in polynomial adjustment 'lactate vs. time' (LM2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the onset time and quality of peribulbar anesthesia with 1% ropivacaine associated or not with hyaluronidase 100 tru/ml for cataract extraction. Methods: Prospective, randomized, double-blind and controlled study including fifty-seven patients, scheduled to undergo peribulbar anesthesia for cataract extraction, allocated to two groups. Group C: 1% ropivacaine with addition of 100 tru/ml hyaluronidase, and Group S 1% ropivacaine, without hyaluronidase. The onset time for globe akinesia was studied at intervals of 2 minutes, using Nicoll's score. We evaluated pain by analogic score during the surgery and the necessity of complementing the anaesthesia. The peribulbar block was considered satisfactory when the Nicoll's score was less than 4. Results: The mean time of onset of block in group C was 4.07 minutes (± 3.24), and in group S 5.03 (± 3.28). There was no statistically significant difference between the groups. Both were similar regarding pain score, no pain was observed in 57.14% of group C, and in 68.97% of group S. The supplementary anesthetic was necessary in 2 cases of group C and in 3 cases of group S. Two cases of bradycardia (heart rate < 50 bpm) were observed during the surgery, and in one case administration of atropine IV was necessary. Conclusion: 1% ropivacaine provided a good quality of anesthesia for cataract extraction, with a faster onset of action in the group with hyaluronidase 100 iu/ml, although without significant difference.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSES: 1) To verify the impact of the creation of the Single Technical Record (STR) at the University of Campinas (Unicamp) Hospital das Clínicas, on the preservation period of corneas which were used in elective penetrating keratoplasties, and 2) to compare the primary failure incidence in cornea penetrating keratoplasties regarding the periods before and after the creation of STR. METHODS: A retrospective study was conducted at the Unicamp Hospital, which evaluated 15 consecutive cornea penetrating keratoplasties between January 1st and April 30th, 2000 and 24 consecutive penetrating keratoplasties between May 1st and September 20th of the same year (corneas under the control of the STR), totaling 39 keratoplasties. RESULTS: The mean time between cornea preparation and transplantation was 3.8 days (±1.78) in the period before STR creation, and 6.0 days (±2.97) after STR creation, representing a 36.7% increase in the preservation time. There was a statistically significant difference (p=0.02) between the two groups. No corneal primary failure was observed among the 39 transplanted patients in both groups. CONCLUSION: Based on the results of this study, it can be concluded that this new concept of the State Transplantation System has caused a statistically significant increase in the conservation period of corneas, which may reduce the period of a clear transplant due to an increased loss of endothelial cells, as well as increase the primary failure incidence or result in a high number of corneas that cannot be used due to having exceeded the preservation time recommended by the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: In Divinolândia (SP), the Consortium of Development of São João da Boa Vista Region Policy (CONDERG), in partnership with State University of Campinas (UNICAMP), has founded an eyeglass store to produce low cost glasses to distribute freely to their customers. The purpose is to analyze the evolution and working process of CONDERG eyeglass store in the last 13 years, since its foundation. METHODS: Data were collected from CONDERG store files from 1988 to 2001. Data regarding the amount of spectacles produced per year, ability to increase the production and store feasibility were analyzed. RESULTS: In 13 years, 16,500 spectacles were supplied. Currently, 400 spectacles are delivered per month, being 200 supported by SUS and the other 200 by CONDERG's own resources. CONCLUSION: The 13-year operation of CONDERG eyeglass store, the free provision of 16,500 spectacles and the increase productive ability have shown this model feasibility.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Univesidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física