426 resultados para Picturesque, The
Resumo:
PURPOSE: To compare intraocular pressure (IOP) rise in normal individuals and primary open-angle glaucoma patients and the safety and efficacy of ibopamine eye drops in different concentrations as a provocative test for glaucoma. METHODS: Glaucoma patients underwent (same eye) the ibopamine provocative test with two concentrations, 1% and 2%, in a random sequence at least 3 weeks apart, but not more than 3 months. The normal individuals were randomly submitted to one of the concentrations of ibopamine (1% and 2%). The test was considered positive if there was an IOP rise greater than 3 or 4 mmHg at 30 or 45 minutes to test which subset of the test has the best sensitivity (Se)/specificity (Sp). RESULTS: There was no statistically significant difference in any of the IOP measurements, comparing 1% with 2% ibopamine. The IOP was significantly higher at 30 and 45 minutes with both concentrations (p<0.001). The best sensitivity/specificity ratio was achieved with the cutoff point set as greater than 3 mmHg at 45 minutes with 2% ibopamine (area under the ROC curve: 0.864, Se: 84.6%; Sp:73.3%). All patients described a slight burning after ibopamine's instillation. CONCLUSION: 2% ibopamine is recommended as a provocative test for glaucoma. Because both concentrations have similar ability to rise IOP, 1% ibopamine may be used to treat ocular hypotony.
Resumo:
PURPOSE: To describe the main success attitudes of young ophthalmologists in the first decade of their career. METHODS: This descriptive study comprised subjects selected from a sample of ophthalmologists who were participating in a congress, using a semi-structured questionnaire. The inclusion criteria were as follows: ophthalmologists under the age of 40 years, within 5-10 years from ophthalmology residency conclusion. The subjects were asked about the three main success attitudes in their personal experience during the first years of ophthalmology practice. After the initial results, the 10 most frequently mentioned attitudes were listed and volunteers were again interviewed to choose, within the latter list, the three main attitudes. RESULTS: Forty-eight ophthalmologists were interviewed, 24 (50%) were male; the mean age was 37 years (SD: 2 years, range: 33-40 years) and the mean time from ophthalmology residency conclusion was 8 years (SD: 1 year, range: 5-10 years). The frequency of such mentioned success attitudes were as follows: to invest in professional updating (22.9%), to have a good relationship with patients and professional partners (18.8%), to prioritize individual and family happiness (12.5%), initially to work in an established group (11.1%), to work in public service (9.7%), to have their own business with a homogeneous group (7.6%), to save money (7.6%), to be ready to resume work (4.2%), to get business administration skills (4.2%), and to have professional insurance (0.7%). CONCLUSIONS: The three main success attitudes consisted in investing in professional updating (22.9%), maintaining a good relationship with patients and professional partners (18.8%), and prioritizing individual and family happiness (12.5%). Although these results should not be generalized, they are helpful not only for those ophthalmologists at the beginning of a career but also those who want to reflect on what to prioritize in their professional practice.
Resumo:
PURPOSE: To evaluate the need for artificial tears by glaucoma patients under topical hypotensive treatment and to identify risk factors associated with it. METHODS: The charts of 175 glaucoma patients under medical treatment and 175 age-matched controls were reviewed. Age, gender, use of artificial tears, number of glaucoma medications used, and duration of treatment were recorded. RESULTS: Significantly more glaucoma patients (n=92; 52.6%) used artificial tears compared to age-matched controls (n=31; 17.7%) (p<0.001). Significantly more females (n=81; 39%) than males (n=42; 28.9%) used artificial tears (p=0.036). When the whole population was analyzed, female gender (OR=1.63) and the presence of glaucoma (OR= 5.14) were risk factors for the use of artificial tears (p<0.05). When the glaucoma population was analyzed, female gender (OR=2.57), number of medications >2 (OR=1.92), and duration of treatment >5 years (OR=2.93) were risk factors for the use of artificial tears (p<0.05). CONCLUSIONS: Topical treatment with antiglaucoma medication is a risk factor for the use of artificial tears. Female gender and long-term treatment of glaucoma with two or more medications were aggravating factors for the need for artificial tears.
Resumo:
PURPOSE: To determine the association between language and number of citations of ophthalmology articles published in Brazilian journals. METHODS: This study was a systematic review. Original articles were identified by review of documents published at the two Brazilian ophthalmology journals indexed at Science Citation Index Expanded - SCIE [Arquivos Brasileiros de Oftalmologia (ABO) and Revista Brasileira de Oftalmologia (RBO)]. All document types (articles and reviews) listed at SCIE in English (English Group) or in Portuguese (Portuguese Group) from January 1, 2008 to December 31, 2009 were included, except: editorial materials; corrections; letters; and biographical items. The primary outcome was the number of citations through the end of second year after publication date. Subgroup analysis included likelihood of citation (cited at least once versus no citation), journal, and year of publication. RESULTS: The search at the web of science revealed 382 articles [107 (28%) in the English Group and 275 (72%) in the Portuguese Group]. Of those, 297 (77.7%) were published at the ABO and 85 (23.3%) at the RBO. The citation counts were statistically significantly higher (P<0.001) in the English Group (1.51 - SD 1.98 - range 0 to 11) compared with the Portuguese Group (0.57 - SD 1.06 - range 0 to 7). The likelihood citation was statistically significant higher (P<0.001) in the English Group (70/107 - 65.4%) compared with the Portuguese Group (89/275 - 32.7%). There were more articles published in English at the ABO (98/297 - 32.9%) than at the RBO (9/85 - 10.6%) [P<0.001]. There were no significant difference (P=0.967) at the proportion of articles published in English at the years 2008 (48/172 - 27.9%) and 2009 (59/210 - 28.1%). CONCLUSION: The number of citations of articles published in Portuguese at Brazilian ophthalmology journals is lower than the published in English. The results of this study suggest that the editorial boards should strongly encourage the authors to adopt English as the main language in their future articles.
Resumo:
134
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física