29 resultados para cylinder specimens


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aware of the diffusion capacity of bleaching in the dental tissues, many orthodontists are subjecting their patients to dental bleaching during orthodontic treatment for esthetic purposes or to anticipate the exchange of esthetic restorations after the orthodontic treatment. For this purpose specific products have been developed in pre-loaded whitening trays designed to fit over and around brackets and wires, with clinical efficacy proven. The objective of this study was to evaluate, through spectrophotometric reflectance, the effectiveness of dental bleaching under orthodontic bracket. Thirty-two bovine incisors crown blocks of 8 mm x 8 mm height lengths were used. Staining of tooth blocks with black tea was performed for six days. They were distributed randomly into 4 groups (1-home bleaching with bracket, 2- home bleaching without bracket, 3- office bleaching with bracket, 4 office bleaching without bracket). The color evaluation was performed (CIE L * a * b *) using color reflectance spectrophotometer. Metal brackets were bonded in groups 1 and 3. The groups 1 and 2 samples were subjected to the carbamide peroxide at 15%, 4 hours daily for 21 days. Groups 3 and 4 were subjected to 3 in-office bleaching treatment sessions, hydrogen peroxide 38%. After removal of the brackets, the second color evaluation was performed in tooth block, difference between the area under the bracket and around it, and after 7 days to verified color stability. Data analysis was performed using the paired t-test and two-way variance analysis and Tukey's. The home bleaching technique proved to be more effective compared to the office bleaching. There was a significant difference between the margin and center color values of the specimens that were subjected to bracket bonding. The bracket bond presence affected the effectiveness of both the home and office bleaching treatments. Key words:Tooth bleaching, spectrophotometry, orthodontics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the dentine bond strength (BS) and the antibacterial activity (AA) of six adhesives against strict anaerobic and facultative bacteria. Three adhesives containing antibacterial components (Gluma 2Bond (glutaraldehyde)/G2B, Clearfil SE Protect (MDPB)/CSP and Peak Universal Bond (PUB)/chlorhexidine) and the same adhesive versions without antibacterial agents (Gluma Comfort Bond/GCB, Clearfil SE Bond/CSB and Peak LC Bond/PLB) were tested. The AA of adhesives and control groups was evaluated by direct contact method against four strict anaerobic and four facultative bacteria. After incubation, according to the appropriate periods of time for each microorganism, the time to kill microorganisms was measured. For BS, the adhesives were applied according to manufacturers' recommendations and teeth restored with composite. Teeth (n=10) were sectioned to obtain bonded beams specimens, which were tested after artificial saliva storage for one week and one year. BS data were analyzed using two-way ANOVA and Tukey test. Saliva storage for one year reduces the BS only for GCB. In general G2B and GCB required at least 24h for killing microorganisms. PUB and PLB killed only strict anaerobic microorganisms after 24h. For CSP the average time to eliminate the Streptococcus mutans and strict anaerobic oral pathogens was 30min. CSB showed no AA against facultative bacteria, but had AA against some strict anaerobic microorganisms. Storage time had no effect on the BS for most of the adhesives. The time required to kill bacteria depended on the type of adhesive and never was less than 10min. Most of the adhesives showed stable bond strength after one year and the Clearfil SE Protect may be a good alternative in restorative procedures performed on dentine, considering its adequate bond strength and better antibacterial activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate pathologic features with implications on surgical radicality in women treated with radical hysterectomy and pelvic lymphadenectomy for cervical cancer stage IA1 with lymph vascular space invasion (LVSI) and stage IA2 by correlating findings in conization and hysterectomy specimens. Women with cervical cancer stage IA1 with LVSI and stage IA2 diagnosed by loop electrosurgical excisional procedure or cold knife conization were treated with radical hysterectomy and pelvic lymphadenectomy from January 1999 to December 2011 in 2 institutions. Fifty patients were enrolled: 40 with stage IA2 and 10 with stage IA1 with LVSI. Median age was 43 (30-67) years. All patients underwent cervical conization for diagnosis (45 loop electrosurgical excisional procedure, 5 cold knife). Lymph vascular space invasion was detected in 15 patients (30%). Two patients had positive pelvic nodes. No parametrial involvement was detected in the entire cohort. Positive margins were present in 35 patients, and residual disease was detected in 22 patients (44%). Positive margins predicted residual disease at radical hysterectomy (P = 0.02). Medium follow-up time was 51 months. One patient developed a pelvic recurrence, and there were no disease-related deaths. Patients with positive margins in cone biopsy specimens have an increased risk of residual disease at radical hysterectomy and require careful evaluation before conservative surgery. Pelvic lymph node evaluation is essential because lymph node metastasis may occur even in early stages. The lack of parametrial invasion in this study reinforces the knowledge that the select group of patients with microinvasive cervical carcinoma stages IA1 LVSI and stage IA2 have a very low risk of parametrial infiltration. Less radical surgery can be carefully considered for these patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although Brazil is the third largest fruit producer in the world, several specimens consumed are not well studied from the chemical viewpoint, especially for quantitative analysis. For this reason and the crescent employment of mass spectrometry (MS) techniques in food science we selected twenty-two phenolic compounds with important biological activities and developed an ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method using electrospray (ESI) in negative ion mode aiming their quantification in largely consumed Brazilian fruits (açaí-do-Amazonas, acerola, cashew apple, camu-camu, pineapple and taperebá). Multiple reaction monitoring (MRM) was applied and the selection of proper product ions for each transition assured high selectivity. Linearity (0.99580%), precision (CV<20%) and extraction recovery rate (>80%) were satisfactory and showed that the method provides an efficient protocol to analyze phenolic compounds in fruit pulp extracts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Triatomine surveillance in rural areas, artificial ecotypes, and natural ecotopes of the cities of Caturama, Ibipitanga, Macaúbas, and Seabra in the south-central region of the Brazilian state of Bahia was carried out between 2008 and 2013. Natural infection by Trypanosoma cruzi was evaluated in the specimens collected to monitor vectors of Chagas disease. A total of 1,357 specimens were collected, and four species were identified: Triatoma sordida (83%), Triatoma lenti (16.4%), Triatoma pseudomaculata (0.5%), and Panstrongylus geniculatus (0.1%). Triatoma sordida was found in four cities, only 0.7% in intradomiciliary environments. Triatoma lenti was found only in Macaúbas; 8.5% were found in intradomiciliary environments, 88.3% in peridomiciliary environments, and 3.1% in sylvatic environments. Natural infection by T. cruzi was 0.5% for T. sordida and 3.1% T. lenti. All of these cases were found in peridomiciliary environments of Macaúbas. As the results show, triatomines were found in intradomiciliary environments in three cities that were surveyed in the south-central region of the state of Bahia. Thus, an epidemiologic survey should be performed to avoid the risk of transmission to the population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Perineural invasion (PNI) and lymphovascular invasion (LVI) have been associated with the risk of local recurrences and lymph node metastasis. The aim of this study was to evaluate the prognostic impact of PNI and LVI in patients with advanced stage squamous cell carcinoma of the tongue and floor of the mouth. One hundred and forty-two patients without previous treatment were selected. These patients underwent radical surgery with neck dissection and adjuvant treatment. Clinicopathological data were retrieved from the medical charts, including histopathology and surgery reports. Univariate analysis was performed to assess the impact of studied variables on survival. Overall survival was negatively influenced by six tumour-related factors: increasing T stage (P = 0.003), more than two clinically positive nodes (P = 0.002), extracapsular spread of lymph node metastasis (P < 0.001), tumour thickness (P = 0.04), PNI (P < 0.001), and LVI (P = 0.012). Disease-free survival was influenced by PNI (P = 0.04), extracapsular spread of lymph node metastasis (P = 0.008), and N stage (P = 0.006). Multivariate analysis showed PNI to be an independent predictor for overall survival (P = 0.01) and disease-free survival (P = 0.03). Thus the presence of PNI in oral carcinoma surgical specimens has a significant impact on survival outcomes in patients with advanced stage tumours submitted to radical surgery and adjuvant radiotherapy/radiochemotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work was done with the objective of studying some physical and mechanical characteristics of the sugarcane bagasse ash added to a soil-cement mixture, in order to obtain an alternative construction material. The sugarcane bagasse ash pre-treatment included both sieving and grinding, before mixing with soil and cement. Different proportions of cement-ash were tested by determining its standard consistence and its compressive resistance at 7 and 28 days age. The various treatments were subsequently applied to the specimens molded with different soil-cement-ash mixtures which in turns were submitted to compaction, unconfined compression and water absorption laboratory tests. The results showed that it is possible to replace up to 20% of Portland cement by sugarcane bagasse ash without any damage to the mixture's compressive strength.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The durability of the cellulose-cement composites is a decisive factor to introduce such material in the market. Polymers have been used in concrete and mortar production to increase its durability. The goal of this work was the physical and mechanical characterization of cellulose-cement composites modified by a polymer and the subsequent durability evaluation. The work also evaluated the dispersion of acrylic polymer in composites made of Pinus caribaea residues. The physical properties observed were water absorption by immersion and bulk density. Rupture modulus and toughness were determined by flexural test. The specimens were obtained from pads, produced by pressing and wet curing. Samples were subjected to accelerated aging tests by repeated wetting and drying cycles and hot-water bath and natural aging. The scanning electron microscopy (SEM) allowed verifying the fiber and composite characteristics along the time. For the composite range analyzed, it was observed the polymer improved the mechanical properties of composites besides a significant decreasing in water absorption. The use of polymer improved the performance of vegetable fiber-cement composites when compared to the conventional mortar, due to water absorption decreasing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rice husk, employed as an energy source at milling industries in Brazil generates, after burning, a dark ash. This residue is not yet conveniently disposed, being currently dumped on large areas, causing environmental problems. This research intended to evaluate the applications of residual rice husk ashes (RHA) as a partial replacement of cement for mortar production. Rice husk ash was chemically characterized through X-ray fluorescence, determination of carbon content, X-ray diffraction, and laser granulometric analysis. Mortar specimens were submitted to two different exposure conditions: internal and external environments at a maximum period of five months. Physical-mechanical testing were compressive strength and ultrasonic pulse velocity (UPV). Although presenting good mechanical performance, the mortar based on ash (RHA) did not present pozolanicity but it can be employed in cement matrices as inert material (filler).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined the influence of three polymerization cycles (1: heat cure - long cycle; 2: heat cure - short cycle; and 3: microwave activation) on the linear dimensions of three denture base resins, immediately after deflasking, and 30 days after storage in distilled water at 37± 2ºC. The acrylic resins used were: Clássico, Lucitone 550 and Acron MC. The first two resins were submitted to all three polymerization cycles, and the Acron MC resin was cured by microwave activation only. The samples had three marks, and dimensions of 65 mm in length, 10 mm in width and 3 mm in thickness. Twenty-one test specimens were fabricated for each combination of resin and cure cycle, and they were submitted to three linear dimensional evaluations for two positions (A and B). The changes were evaluated using a microscope. The results indicated that all acrylic resins, regardless of the cure cycle, showed increased linear dimension after 30 days of storage in water. The composition of the acrylic resin affected the results more than the cure cycles, and the conventional acrylic resin (Lucitone 550 and Clássico) cured by microwave activation presented similar results when compared with the resin specific for microwave activation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare two methods of surface roughness analysis, perfilometry and spectrophotometry, applied to the surface of ionomeric materials (Chelon Fil, Vitremer and Dyract), submitted to different surface finishing treatments. For the perfilometric analysis, sixty specimens of each material were made and randomly separated into three experimental groups. The average surface roughness (Ra, mm) was measured on each specimen by a surface perfilometer (Mitutoyo Surftest 211). The spectrophotometric analysis consisted in quantifying the dye impregnated in the samples. The dyes used were 0.5% fuchsin and 0.5% erythrosin. Data were submitted to variance analysis (ANOVA) and t-Student test at a 0.05 significance level. There was no linear correlation between average roughness and superficial deposition of dye. Perfilometric analysis revealed that 12- and 30-bladed carbide burs caused the roughest surface of Chelon Fil, followed by Sof-Lex discs and mylar band. There were no significant differences between the specimens submitted to finishing and polishing with Sof-Lex discs and the control group (mylar band) for Vitremer, nevertheless, the highest Ra values were obtained when 12- and 30-bladed burs were used. For Dyract, there was no significant difference between the three treatments. The mean values of superficial deposition of dye for Chelon Fil, Vitremer and Dyract were: 1.7261, 1.4759, 1.3318, respectively. There were no significant differences between the restorative materials when different finishing and polishing systems were used.