17 resultados para IN-VITRO INHIBITION


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess the sociodemographic profile and gynecologic and obstetric characteristics of women referred to a public reference center in Campinas, Brazil, for in vitro fertilization (IVF). Women referred between April 1, 2008, and October 31, 2009, were eligible for inclusion in a cross-sectional study. Participants were interviewed about sociodemographic characteristics, obstetric and gynecologic history, and etiologic factors resulting in the referral. Preliminary clinical examinations performed elsewhere were evaluated. A total of 176 women were included, of whom 129 (73.3%) presented with tubal factor infertility. Tubal ligation had been performed in 66 (37.5%) women. Overall, 121 (68.8%) women were aged 30 years old or less, 110 (62.5%) had received more than 8 years of schooling, 123 (69.6%) had had infertility for up to 5 years, and 99 (56.3%) did not have any children. Moreover, 25 (14.2%) women had endometriosis and 25 (14.2%) had a male factor issue. A previous ectopic pregnancy was reported for 20 (11.4%) women and pelvic inflammatory disease for 49 (27.8%). Tubal factor infertility was the most common indication for IVF. Preventive measures are required, in addition to policies that ensure access to high-complexity treatments in the public sector.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to determine the effectiveness and reliability of laser fluorescence measurements in relation to occlusal caries diagnosis. DIAGNOdent 2095 (Kavo, Biberach, Germany), which has been developed especially for caries diagnosis, was utilized. Five (5) teeth were examined in the pilot test; after that, ten (10) teeth were examined in order to calibrate both examiners. Data were obtained from 66 teeth (36 molars and 30 premolars), totalizing 144 sites identified through photographs of the occlusal surfaces. Reproducibility was evaluated in 10 teeth. The interexaminer Spearman correlation (r) was 0.89 and the intra-examiner, 0.93 and 0.97 (examiner A and B, respectively). Validation was carried out by histological examination (stereomicroscope). For the two examiners the sensitivity of the device was relatively high, varying from 0.81 to 1.00, while specificity varied according to which validation criterion was used (0.77 - 0.86: enamel lesion / 0.52 - 0.59: dentin lesion). It was concluded that DIAGNodent presented good capacity of identifying any alteration of the dental surface, nevertheless it presents the disadvantage of accomplishing many false-positive diagnosis when the validation criterion is dentin lesion.