20 resultados para Epilepsia-Diagnosis-Tratamiento


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seizures happen for brief periods of time, but the feelings of anxiety and helplessness, adaptation to the restrictions impose by the life-style and variety of other problems affect more the quality of life in epilepsy. This study proposes a protocol that regards the objectives of a quality of life assessment in health and is applied to a population that attends a university hospital. It contains 65 items and assesses the psychosocial performance, physical limitation, cognitive aspects, perception of control, self-concept, as well as perception of health and quality of life. The results of reliability and validity are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FISH has been used as a complement to classical cytogenetics in the detection of mosaicism in sex chromosome anomalies. The aim of this study is to describe three cases in which the final diagnosis could only be achieved by FISH. Case 1 was an 8-year-old 46,XY girl with normal female genitalia referred to our service because of short stature. FISH analysis of lymphocytes with probes for the X and Y centromeres identified a 45,X/46,X,idic(Y) constitution, and established the diagnosis of Turner syndrome. Case 2 was a 21-month-old 46,XY boy with genital ambiguity (penile hypospadias, right testis, and left streak gonad). FISH analysis of lymphocytes and buccal smear identified a 45,X/46,XY karyotype, leading to diagnosis of mixed gonadal dysgenesis. Case 3 was a 47,XYY 19-year-old boy with delayed neuromotor development, learning disabilities, psychological problems, tall stature, small testes, elevated gonadotropins, and azoospermia. FISH analysis of lymphocytes and buccal smear identified a 47,XYY/48,XXYY constitution. Cases 1 and 2 illustrate the phenotypic variability of the 45,X/46,XY mosaicism, and the importance of detection of the 45,X cell line for proper management and follow-up. In case 3, abnormal gonadal function could be explained by the 48,XXYY cell line. The use of FISH in clinical practice is particularly relevant when classical cytogenetic analysis yields normal or uncertain results in patients with features of sex chromosome aneuploidy. Arq Bras Endocrinol Metab. 2012;56(8):545-51

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To verify if the frequency of spontaneous pubertal development among girls with Turner syndrome (TS) diagnosed in infancy and childhood is greater than that of patients diagnosed later. SUBJECTS AND METHODS: Thirty three girls aged < 10 years at the time of diagnosis were evaluated regarding pubertal development. The frequency of spontaneous puberty was compared with that of girls aged > 13 years diagnosed at the same service. RESULTS: Sixteen of 32 informative patients had signs of spontaneous puberty, a frequency greater than that of patients diagnosed later. In six patients, there was no progression of puberty; menarche occurred in six, and one became pregnant, but the fetus was a stillborn. Spontaneous puberty was absent in all cases with 45,X karyotype. CONCLUSIONS: The greater prevalence of spontaneous puberty in girls whose diagnosis was not based on pubertal delay suggests that, among those diagnosed later, there is a bias towards patients with hypogonadism. Arq Bras Endocrinol Metab. 2012;56(9):653-7

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the sensitivity and specificity of machine learning classifiers (MLCs) for glaucoma diagnosis using Spectral Domain OCT (SD-OCT) and standard automated perimetry (SAP). METHODS: Observational cross-sectional study. Sixty two glaucoma patients and 48 healthy individuals were included. All patients underwent a complete ophthalmologic examination, achromatic standard automated perimetry (SAP) and retinal nerve fiber layer (RNFL) imaging with SD-OCT (Cirrus HD-OCT; Carl Zeiss Meditec Inc., Dublin, California). Receiver operating characteristic (ROC) curves were obtained for all SD-OCT parameters and global indices of SAP. Subsequently, the following MLCs were tested using parameters from the SD-OCT and SAP: Bagging (BAG), Naive-Bayes (NB), Multilayer Perceptron (MLP), Radial Basis Function (RBF), Random Forest (RAN), Ensemble Selection (ENS), Classification Tree (CTREE), Ada Boost M1(ADA),Support Vector Machine Linear (SVML) and Support Vector Machine Gaussian (SVMG). Areas under the receiver operating characteristic curves (aROC) obtained for isolated SAP and OCT parameters were compared with MLCs using OCT+SAP data. RESULTS: Combining OCT and SAP data, MLCs' aROCs varied from 0.777(CTREE) to 0.946 (RAN).The best OCT+SAP aROC obtained with RAN (0.946) was significantly larger the best single OCT parameter (p<0.05), but was not significantly different from the aROC obtained with the best single SAP parameter (p=0.19). CONCLUSION: Machine learning classifiers trained on OCT and SAP data can successfully discriminate between healthy and glaucomatous eyes. The combination of OCT and SAP measurements improved the diagnostic accuracy compared with OCT data alone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física