25 resultados para automatic meter reading
em Scielo Sa
Resumo:
The word tradition has a very specific meaning in linguistics: the passing down of a text, which may have been completed or corrected by different copyists at different times, when the concept of authorship was not the same as it is today. When reading an ancient text the word tradition must be in the reader's mind. To discuss one of the problems an ancient text poses to its modern readers, this work deals with one of the first printed medical texts in Portuguese, the Regimento proueytoso contra ha pestenença, and draws a parallel between it and two related texts, A moche profitable treatise against the pestilence, and the Recopilaçam das cousas que conuem guardar se no modo de preseruar à Cidade de Lixboa E os sãos, & curar os que esteuerem enfermos de Peste. The problems which arise out of the textual structure of those books show how difficult is to establish a tradition of another type, the medical tradition. The linguistic study of the innumerable medieval plague treatises may throw light on the continuities and on the disruptions of the so-called hippocratic-galenical medical tradition.
Resumo:
In several countries, surveillance of insect vectors is accomplished with automatic traps. This study addressed the performance of Mosquito Magnet® Independence (MMI) in comparison with those of CDC with CO2 and lactic acid (CDC-A) and CDC light trap (CDC-LT). The collection sites were in a rural region located in a fragment of secondary tropical Atlantic rainforest, southeastern Brazil. Limatus durhami and Limatus flavisetosus were the dominant species in the MMI, whereas Ochlerotatus scapularis was most abundant in CDC-A. Culex ribeirensis and Culex sacchettae were dominant species in the CDC-LT. Comparisons among traps were based on diversity indices. Results from the diversity analyses showed that the MMI captured a higher abundance of mosquitoes and that the species richness estimated with it was higher than with CDC-LT. Contrasting, difference between MMI and CDC-A was not statistically significant. Consequently, the latter trap seems to be both an alternative for the MMI and complementary to it for ecological studies and entomological surveillance.
Resumo:
A form of increasing the efficiency of N fertilizer is by coating urea with polymers to reduce ammonia volatilization. The aim of this study was to evaluate the effect of polymer-coated urea on the control of ammonia volatilization, yield and nutritional characteristics of maize. The experiment was carried out during one maize growing cycle in 2009/10 on a Geric Ferralsol, inUberlândia, MG, Brazil. Nitrogen fertilizers were applied as topdressing on the soil surface in the following urea treatments: polymer-coated urea at rates of 45, 67.5 and 90 kg ha-1 N and one control treatment (no N), in randomized blocks with four replications. Nitrogen application had a favorable effect on N concentrations in leaves and grains, Soil Plant Analysis Development (SPAD) chlorophyll meter readings and on grain yield, where as coated urea had no effect on the volatilization rates, SPAD readings and N leaf and grain concentration, nor on grain yield in comparison to conventional fertilization.
Resumo:
The close relationship between the chlorophyll-meters readings and the total chlorophyll and nitrogen contents in leaves, has allowed their evaluation both in annual and perennial species. Besides, some physiological events such as the CO2 assimilation have also been estimated by chlorophyll meters. This work was carried out aiming to evaluate the gas exchanges of peach palms as a function of the chlorophyll SPAD-Meter readings. Three year-old peach palms from Yurimaguas, Peru were studied in Ubatuba, SP, Brazil, spaced 2 x 1 m in area under a natural gradient of organic matter which allowed four plots to be considered, according to the peach palms leaves colors, from light yellow to dark green. The SPAD readings and the stomatal frequency of leaflets were evaluated. The photosynthetic photon flux density (PPFD, μmol m-2 s-1), the leaf temperature (Tleaf, ºC), the CO2 assimilation (A, μmol m-2 s-1), the stomatal conductance (g s, mol m-2 s-1), the transpiration (E, mmol m-2 s-1) and the intercellular CO2 concentration (Ci, μmol mol-1) were evaluated with a portable infrared gas analyzer (LCA-4, ADC BioScientific Ltd., Great Amwell, U.K.). A linear increase in the CO2 assimilation as a function of the SPAD readings (y = -0.34 + 0.19x, R² = 0.99), indicates that they can be a rapid and cheap complementary method to evaluate in peach palms some important physiological events, such as CO2 assimilation.
Resumo:
The study assessed growth and physiological parameters of 'Sunrise Golden' and 'Tainung 01' papaya seedlings grown in 280mL plastic tubes and watered using a low-cost automatic irrigation system adjusted to operate at substrate water tension for starting irrigation (STI) of 3.0, 6.0 or 9.0 kPa. The water depths applied by the dripping system and drainage were monitored during germination and seedling growth. Germination, emergence velocity index (EVI), leaf area, plant height, shoot and root dry weight, stomatal conductance, relative water content (RWC) and relative chlorophyll content (RCC) were evaluated. Soil nutrient levels were determined by electrical conductivity (EC). Water use efficiency (WUE) corresponded to the ratio of plant dry mass to depth of water applied. STI settings did not affect papaya germination or EVI. System configuration to 3.0 and 6.0 kPa STI exhibited the highest drainage and lowest EC and RCC, indicating soil nutrient loss and plant nutrient deficiency. Drainage was greater in tubes planted with the 'Tainung 01' variety, which developed smaller root systems and lower stomatal conductance than 'Sunrise Golden' seedlings. The highest values for shoot dry weight and WEU were obtained at 6.0 kPa STI for 'Sunrise Golden' (0.62 g and 0.69 g L-1) and at 9.0 kPa in 'Tainung 01' (0.35 g and 0.82 g L-1). RWC at 9.0 kPa STI was lower than at 3.0 kPa in both varieties. The results indicate that the low-cost technology developed for irrigation automation is promising. Even so, new studies are needed to evaluate low-flow irrigation systems as well as the nutrient and water needs of different papaya varieties.
Resumo:
In general, laboratory activities are costly in terms of time, space, and money. As such, the ability to provide realistically simulated laboratory data that enables students to practice data analysis techniques as a complementary activity would be expected to reduce these costs while opening up very interesting possibilities. In the present work, a novel methodology is presented for design of analytical chemistry instrumental analysis exercises that can be automatically personalized for each student and the results evaluated immediately. The proposed system provides each student with a different set of experimental data generated randomly while satisfying a set of constraints, rather than using data obtained from actual laboratory work. This allows the instructor to provide students with a set of practical problems to complement their regular laboratory work along with the corresponding feedback provided by the system's automatic evaluation process. To this end, the Goodle Grading Management System (GMS), an innovative web-based educational tool for automating the collection and assessment of practical exercises for engineering and scientific courses, was developed. The proposed methodology takes full advantage of the Goodle GMS fusion code architecture. The design of a particular exercise is provided ad hoc by the instructor and requires basic Matlab knowledge. The system has been employed with satisfactory results in several university courses. To demonstrate the automatic evaluation process, three exercises are presented in detail. The first exercise involves a linear regression analysis of data and the calculation of the quality parameters of an instrumental analysis method. The second and third exercises address two different comparison tests, a comparison test of the mean and a t-paired test.
Resumo:
This work objectified to evaluate the efficiency of two meter mechanism of corn seeds when submitted to different forward speed and soil management system during the non-tillage seeding. It was used a factorial design in randomized blocks. The factors whose effects were examined were related to the seeders with pneumatic and horizontal disk meter mechanisms for the distribution of the seeds, to the set tractor-seeder forward speeds (4.4; 8.0 and 9.8 km h-1), and to the soil management system considering the corn no-tillage seeding over minimum tillage with chisel plow and the no-tillage system for the seeding of oat culture (Avena strigosa Schreb). It was verified that the forward speed didn't influence the initial and final stands of plants but it interfered in the regularity of longitudinal distribution of plants. The smallest speed provided the largest percentile of normal spacing between plants. The pneumatic meter mechanism presented better performance than the horizontal disk perforated in the longitudinal distribution of plants. About corn productivity aspect it's indifferent the recommendation of use for pneumatic and perforated horizontal disk meter mechanism of seeds.
Resumo:
This study aimed to evaluate the effect of horizontal plate meter with oblong holes operating with one or two seed outlets at different speeds over the accuracy of longitudinal distribution of common bean seeds (Phaseolus vulgaris L.). The experiment was performed in laboratory using the meter with one and two seed outlet points in relation to ten tangential disk plate speeds (0.03 to 0.30 m s-1). It was used a complete randomized design with four replications, summing up 80 experimental treatments. Tangential speed quantitative factor was estimated through a 2nd order polynomial regression. There was no significant difference in the behavior of the seed meter operating with one or two outlets in the metering of bean seeds in all tested speeds, with percentage of single seeds spacing over 60% in tangential speeds below of 0.24 m s-1.
Resumo:
The use of precision farming tools in pesticide application technology can improve the techniques effectiveness during the spraying. Thus, this study aimed to compare automatic and manual systems to interrupt the syrup flow in the spray bar sections when applied in overlapped areas. The sprayings were carried out in eight places in completely randomized design. It was compared the spray consumption and the sprayed area in relation to the total area. The results indicated that in sprays performed with the automatic system there was an average savings of 17.2% of the sprayed volume. The sprayed area using the bar section's automatic control was an average 6.1% lower than the sprayed area with manual control.
Resumo:
The formal calibration procedure of a phase fraction meter is based on registering the outputs resulting from imposed phase fractions at known flow regimes. This can be straightforwardly done in laboratory conditions, but is rarely the case in industrial conditions, and particularly for on-site applications. Thus, there is a clear need for less restrictive calibration methods regarding to the prior knowledge of the complete set of inlet conditions. A new procedure is proposed in this work for the on-site construction of the calibration curve from total flown mass values of the homogeneous dispersed phase. The solution is obtained by minimizing a convenient error functional, assembled with data from redundant tests to handle the intrinsic ill-conditioned nature of the problem. Numerical simulations performed for increasing error levels demonstrate that acceptable calibration curves can be reconstructed, even from total mass measured within a precision of up to 2%. Consequently, the method can readily be applied, especially in on-site calibration problems in which classical procedures fail due to the impossibility of having a strict control of all the input/output parameters.
Resumo:
Production machines for next generation LSIs such as 4G-DRAMs and for large liquid crystal displays such as 0.5mx0.5m size, and information equipment such as magnetic hard disks and DVDs must have the positioning accuracy of a nano-meter order. To realize such a high degree of the positioning accuracy, not only precision machine elements and mechanisms but also high precision sensors, actuators and controller design techniques becomes crucial. This paper introduces recent topics of precision positioning and motion control technology in Japan.
Resumo:
Reading the human Y chromosome: the emerging DNA markers and human genetic history.
Resumo:
We describe a low-cost, high quality device capable of monitoring indirect activity by detecting touch-release events on a conducting surface, i.e., the animal's cage cover. In addition to the detecting sensor itself, the system includes an IBM PC interface for prompt data storage. The hardware/software design, while serving for other purposes, is used to record the circadian activity rhythm pattern of rats with time in an automated computerized fashion using minimal cost computer equipment (IBM PC XT). Once the sensor detects a touch-release action of the rat in the upper portion of the cage, the interface sends a command to the PC which records the time (hours-minutes-seconds) when the activity occurred. As a result, the computer builds up several files (one per detector/sensor) containing a time list of all recorded events. Data can be visualized in terms of actograms, indicating the number of detections per hour, and analyzed by mathematical tools such as Fast Fourier Transform (FFT) or cosinor. In order to demonstrate method validation, an experiment was conducted on 8 Wistar rats under 12/12-h light/dark cycle conditions (lights on at 7:00 a.m.). Results show a biological validation of the method since it detected the presence of circadian activity rhythm patterns in the behavior of the rats
Resumo:
The objective of the present investigation was to compare the sensitivity of an electronic nociceptive mechanical paw test with classical mechanical tests to quantify the intensity variation of inflammatory nociception. The electronic pressure-meter test consists of inducing the hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared with the classical von Frey filaments test and with the rat paw constant pressure test, a modification of the Randall and Selitto test developed by our group. When comparing the three methods, the electronic pressure-meter and the rat paw constant pressure test, but not the von Frey filaments test, detected time vs treatment interactions in prostaglandin E2 (PGE2)-induced hypernociception. Both methods also detected the PGE2-induced hypernociception in dose- (50-400 ng/paw) and time- (1-4 h) dependent manners, and time vs treatment interactions induced by carrageenin (25-400 µg/paw). Furthermore, the electronic pressure-meter test was more sensitive at early times, whereas the constant pressure test was more sensitive at later times. Moreover, the electronic pressure-meter test detected the dose-dependent antinociceptive effect of local indomethacin (30-300 µg/paw) and dipyrone (80-320 µg/paw) on carrageenin- (200 µg/paw) and PGE2- (100 ng/paw) induced hypernociception, respectively, and also detected the ineffectiveness of indomethacin (300 µg) on the effect of PGE2. Our results show that the electronic pressure-meter provides a sensitive, objective and quantitative mechanical nociceptive test that could be useful to characterize new nociceptive inflammatory mediators and also to evaluate new peripheral analgesic substances.
Resumo:
The aim of the present investigation was to describe and validate an electronic mechanical test for quantification of the intensity of inflammatory nociception in mice. The electronic pressure-meter test consists of inducing the animal hindpaw flexion reflex by poking the plantar region with a polypropylene pipette tip adapted to a hand-held force transducer. This method was compared to the classical von Frey filaments test in which pressure intensity is automatically recorded after the nociceptive hindpaw flexion reflex. The electronic pressure-meter and the von Frey filaments were used to detect time versus treatment interactions of carrageenin-induced hypernociception. In two separate experiments, the electronic pressure-meter was more sensitive than the von Frey filaments for the detection of the increase in nociception (hypernociception) induced by small doses of carrageenin (30 µg). The electronic pressure-meter detected the antinociceptive effect of non-steroidal drugs in a dose-dependent manner. Indomethacin administered intraperitoneally (1.8-15 mg/kg) or intraplantarly (30-300 µg/paw) prevented the hypersensitive effect of carrageenin (100 µg/paw). The electronic pressure-meter also detected the hypernociceptive effect of prostaglandin E2 (PGE2; 10-100 ng) in a dose-dependent manner. The hypernociceptive effect of PGE2 (100 ng) was blocked by dipyrone (160 and 320 µg/paw) but not by intraplantar administration of indomethacin (300 µg/paw). The present results validate the use of the electronic pressure-meter as more sensitive than the von Frey filaments in mice. Furthermore, it is an objective and quantitative nociceptive test for the evaluation of the peripheral antinociceptive effect of anti-inflammatory analgesic drugs, which inhibit prostaglandin synthesis (indomethacin) or directly block the ongoing hypernociception (dipyrone).