19 resultados para wide-angle
em Scielo Saúde Pública - SP
Resumo:
Pb/Ti, Sn and Mg-based nanocomposite materials were prepared by the high-energy mechanical milling of commercial powders. The surface of these ceramic compounds was strongly influenced by the doping, diameter of the milling spheres and time of the mechanical milling (amorphization process). Such milling leads to the formation of nanocrystalline materials. The mechanical processing parameters of these compounds were investigated through Brunauer, Emmett and Teller isotherms, wide angle X-ray diffraction, transmission electron microscopy and CO2 adsorption.
Resumo:
The product of catalytic activity of the enzyme phospholipase A2, which resembles the core unit of animal toxins, on phospholipids is a 1:1 mixture of lysolipid and fatty acid. This mixture was studied by time-resolved simultaneous small- and wide angle x-ray diffraction over the temperature range from 23 to 53.5ºC. An unusually large lamellar structure was observed, with d = 11 nm, contradicting the complex functional dimer model between lysolipid and fatty acid. It can be explained by formation of a "double-bilayer", a new phase consisting of two different bilayers, one formed by lysophospholipid and other by fatty acid, bound together by head group interactions. Its strucutre was confirmed by simulations of the X-ray scattering pattern.
Resumo:
One of the problems that slows the development of off-line programming is the low static and dynamic positioning accuracy of robots. Robot calibration improves the positioning accuracy and can also be used as a diagnostic tool in robot production and maintenance. A large number of robot measurement systems are now available commercially. Yet, there is a dearth of systems that are portable, accurate and low cost. In this work a measurement system that can fill this gap in local calibration is presented. The measurement system consists of a single CCD camera mounted on the robot tool flange with a wide angle lens, and uses space resection models to measure the end-effector pose relative to a world coordinate system, considering radial distortions. Scale factors and image center are obtained with innovative techniques, making use of a multiview approach. The target plate consists of a grid of white dots impressed on a black photographic paper, and mounted on the sides of a 90-degree angle plate. Results show that the achieved average accuracy varies from 0.2mm to 0.4mm, at distances from the target from 600mm to 1000mm respectively, with different camera orientations.
Resumo:
An alternative vector control method, using lambda-cyhalothrin impregnated wide-mesh gauze covering openings in the walls of the houses was developed in an area in the Eastern part of the interior of Suriname. Experimental hut observations showed that Anopheles darlingi greatly reduced their biting activity (99-100%) during the first 5 months after impregnation. A model assay showed high mortality both of mosquitoes repelled by the gauze as well as of those that succeeded in getting through it. A field application test in 270 huts showed good acceptance by the population and good durability of the applied gauze. After introducing the method in the entire working area, replacing DDT residual housespraying, the malaria prevalence, of 25-37% before application dropped and stabilized at between 5 and 10% within one year. The operational costs were less than those of the previously used DDT housespraying program, due to a 50% reduction in the cost of materials used. The method using widemesh gauze impregnated with lambdacyhalothrin strongly affects the behavior of An. darlingi. It is important to examine the effect of the method on malaria transmission further, since data indirectly obtained suggest substantial positive results.
Resumo:
Mebendazole, albendazole, levamisole and thiabendazole are well known as active drugs against several nematode species, and against cestodes as well, when the first two drugs are considered. None of the drugs have proven activity, however, against trematodes. We tested the effect of these drugs on the fecal shedding of schistosome eggs and the recovering of adult schistosomes, after portal perfusion in Schistosoma mansoni experimentally infected mice. Balb/c mice infected with 80 S. mansoni cercariae were divided into three groups, each in turn subdivided into four other groups, for each tested drug. The first group was treated with each one of the studied drugs 25 days after S. mansoni infection; the second group was submitted to treatment with each one of the drugs 60 days after infection. Finally, the third group, considered as control, received no treatment. No effect upon fecal shedding of S. mansoni eggs and recovering of schistosomes after portal perfusion was observed when mice were treated with either mebendazole or albendazole. Mice treated with either levamisole or thiabendazole, on the other hand, showed a significant reduction in the recovering of adult schistosomes after portal perfusion, mainly when both drugs were given during the schistosomula evolution period, i.e., 25 days after cercariae penetration, probably due to unspecific immunomodulation
Resumo:
Background:The QRS-T angle correlates with prognosis in patients with heart failure and coronary artery disease, reflected by an increase in mortality proportional to an increase in the difference between the axes of the QRS complex and T wave in the frontal plane. The value of this correlation in patients with Chagas heart disease is currently unknown.Objective:Determine the correlation of the QRS-T angle and the risk of induction of ventricular tachycardia / ventricular fibrillation (VT / VF) during electrophysiological study (EPS) in patients with Chagas disease.Methods:Case-control study at a tertiary center. Patients without induction of VT / VF on EPS were used as controls. The QRS-T angle was categorized as normal (0-105º), borderline (105-135º) or abnormal (135-180º). Differences between groups for continuous variables were analyzed with the t test or Mann-Whitney test, and for categorical variables with Fisher's exact test. P values < 0.05 were considered significant.Results:Of 116 patients undergoing EPS, 37.9% were excluded due to incomplete information / inactive records or due to the impossibility to correctly calculate the QRS-T angle (presence of left bundle branch block and atrial fibrillation). Of 72 patients included in the study, 31 induced VT / VF on EPS. Of these, the QRS-T angle was normal in 41.9%, borderline in 12.9% and abnormal in 45.2%. Among patients without induction of VT / VF on EPS, the QRS-T angle was normal in 63.4%, borderline in 14.6% and abnormal in 17.1% (p = 0.04). When compared with patients with normal QRS-T angle, those with abnormal angle had a fourfold higher risk of inducing ventricular tachycardia / ventricular fibrillation on EPS [odds ratio (OR) 4; confidence interval (CI) 1.298-12.325; p = 0.028]. After adjustment for other variables such as age, ejection fraction (EF) and QRS size, there was a trend for the abnormal QRS-T angle to identify patients with increased risk of inducing VT / VF during EPS (OR 3.95; CI 0.99-15.82; p = 0.052). The EF also emerged as a predictor of induction of VT / VF: for each point increase in EF, there was a 4% reduction in the rate of sustained ventricular arrhythmia on EPS.Conclusions:Changes in the QRS-T angle and decreases in EF were associated with an increased risk of induction of VT / VF on EPS.
Resumo:
A new tick, Amblyomma parkeri, n. sp., is described as a parasite of Coendu sp. from S. Paulo, Brazil. Female holotype, nymph and larva are described (Figs. 2 e 3). The n. sp. differs completly from Koch's species Amblyomma longirostre, the common parasite of the Erethizotidae. Standard data for measures of the female dorsal scutum ixodidae are proposed as follows (fig. 1): PA = Antero-posterior; PB = Postero-basal; PM = Postero-median; TT = Transversal; OO = Inter-ocular; OT= Occulo-transversal; SS = Inter-scapular; CC = Cervical; PT = Postero-transversal; ST = Scapulo-transversal; NPT = Normal to the postero-transversal; NST = Normal to the scapulo-transversal. In the female holotype the standard data are as follows: PA = 2.00 mm; PB = 2.26 mm; PM = 1.10 mm; TT = 2.20 mm; OO = 2.26 mm; SS = 0,84 mm; CC = 0.63 mm; SC = 0.12 mm; NPT = 0.20mm; STN = 0.1 mm. Peritrema 0.80 x 0.42 mm with a narrow postero-internal angle and a large, elongated macula. Coxa I with two short spines and all other coxae with only one shorter spine, shortest in coxa IV. Hypostoma spatulated with formula 3/3. Gnathosoma 1.42 mm long and basis 0.63 mm long by 0.84 greatest wide. Palpi with smoth external surface, 1.00 mm long. Type lot No. 4458 from Cotia, S. Paulo, Brazil; in the acarological collection of the Escola Paulista de Medicina, S. Paulo. Ixodes didelphidis, n. sp., differing from Ixodes loricatus Neumann by the shape of the peritremata (figs. 4 a 5) of the male and female and by the number of the punctations in this organ is described form Didelphidae, Muridae and Cavidae. Twenty eight lots were obtained from Anápolis, Goiás, Brasil, where I. loricatus is subtituded by the n. sp. under description. Comparison with NEUMANN'S types of I. loricatus was possible through the courtesy of Prof. A. BRIZARD from Toulouse, who kindly loaned NEUMANN'S material. Female cotypes N° 40 and male allotype N° 531 in the Collection of Ixodidae of the Oswaldo Cruz Institute.
Leprosy, a neglected disease that causes a wide variety of clinical conditions in tropical countries
Resumo:
Leprosy is an ancient disease that remains endemic and continues to be a major public health problem in some tropical countries, where it has been internationally recognized as being linked to the underdevelopment conditions. The natural course of the disease covers a wide variety of clinical conditions with systemic involvement. In this paper, we review the findings obtained in studies of the pathological mechanisms of leprosy, including a survey of the literature and of our own work. The understanding and control of the wide variety of clinical conditions should help improve patient care and thus prevent the onset of physical impairment and the stigma of the disease.
Resumo:
The organophosphate temephos has been the main insecticide used against larvae of the dengue and yellow fever mosquito (Aedes aegypti) in Brazil since the mid-1980s. Reports of resistance date back to 1995; however, no systematic reports of widespread temephos resistance have occurred to date. As resistance investigation is paramount for strategic decision-making by health officials, our objective here was to investigate the spatial and temporal spread of temephos resistance in Ae. aegypti in Brazil for the last 12 years using discriminating temephos concentrations and the bioassay protocols of the World Health Organization. The mortality results obtained were subjected to spatial analysis for distance interpolation using semi-variance models to generate maps that depict the spread of temephos resistance in Brazil since 1999. The problem has been expanding. Since 2002-2003, approximately half the country has exhibited mosquito populations resistant to temephos. The frequency of temephos resistance and, likely, control failures, which start when the insecticide mortality level drops below 80%, has increased even further since 2004. Few parts of Brazil are able to achieve the target 80% efficacy threshold by 2010/2011, resulting in a significant risk of control failure by temephos in most of the country. The widespread resistance to temephos in Brazilian Ae. aegypti populations greatly compromise effective mosquito control efforts using this insecticide and indicates the urgent need to identify alternative insecticides aided by the preventive elimination of potential mosquito breeding sites.
Resumo:
The chemistry of cyclopentadiene rings has been widely studied. This review article deals with a similar chemistry of new compounds containing from 1 to 5 phosphorus atoms on the ring substituting the carbon atoms. The neutral rings containing one, two and three phosphorus atoms can be used as building blocks for the synthesis of new organic compounds containing phosphorus. These rings plus the anionic ones also show great potential as ligands in coordination chemistry. The aim of this article is to show how important this new area is and how diverse the chemistry related to a single type of ring can be.
Resumo:
The application of one-dimensional proton high-resolution magic angle spinning (¹H HR-MAS) NMR combined with a typical advantages of solid and liquid-state NMR techniques was used as input variables for the multivariate statistical analysis. In this paper, different cultivars of beans (Phaseolus vulgaris) developed and in development by Embrapa - Arroz e Feijão were analyzed by ¹H HR-MAS, which have been demonstrated to be a valuable tool in its differentiation according chemical composition and avoid the manipulation of the samples as used in other techniques.
Resumo:
Photoacoustic spectroscopy provides information about both amplitude and phase of the response of a system to an optical excitation process. This paper presents the studies of the phase in the electron transfer process between octaethylporphyn (OEP) and quinone molecules dispersed in a polymeric matrix. It was observed a tendency in the phase behavior to small values only in the spectral region near to 620 nm, while for shorter wavelength did not show any tendency. These measurements suggested that the electron transfer to acceptor occurred with the participation of octaethylporphyn singlet excited state.
Resumo:
This work describes a method to determine Cu at wide range concentrations in a single run without need of further dilutions employing high-resolution continuum source flame atomic absorption spectrometry. Different atomic lines for Cu at 324.754 nm, 327.396 nm, 222.570 nm, 249.215 nm and 224.426 nm were evaluated and main figures of merit established. Absorbance measurements at 324.754 nm, 249.215 nm and 224.426 nm allows the determination of Cu in the 0.07 - 5.0 mg L-1, 5.0 - 100 mg L-1 and 100 - 800 mg L-1 concentration intervals respectively with linear correlation coefficients better than 0.998. Limits of detection were 21 µg L-1, 310 µg L-1 and 1400 µg L-1 for 324.754 nm, 249.215 nm and 224.426 nm, respectively and relative standard deviations (n = 12) were £ 2.7%. The proposed method was applied to water samples spiked with Cu and the results were in agreement at a 95% of confidence level (paired t-test) with those obtained by line-source flame atomic absorption spectrometry.
Resumo:
ABSTRACTFour stands of 28-year-old radiata pine (Pinus radiata D. Don) grown in the eighth region (Biobio) of Chile were sampled to determine the effect of tree spacing on the microfibril angle. The samples were taken at two different stem levels of the tree, 2.5 m and 7.5 m, with increment strip taken in the Nothern direction. The four experimental stands were characterized by the following spacing 2x2, 2x3, 3x4 and 4x4. The microfibril angle was measured by X-ray diffraction with the SilviScan technology at the FP-Innovation-Paprican Division in Vancouver, Canada. The results showed a significant effect of tree spacing on the microfibril angle in both juvenile wood and mature wood as well as at the two stem levels considered. The minimum (9.42º) was reached in 2x2 stand at 7.5 m in mature wood, while maximum microfibril angle (24.54º) was obtained in 2x3 stand at 2.5 m in juvenile wood. Regarding the effect of tree spacing, 4x4 stand had the lowest microfibril angle,except in mature wood at 7.5 m where 4x4 had the highest microfibril angle (11°) of the four stands.
Resumo:
Soil physical quality can be easily and quickly evaluated by using simple equipment to identify levels of soil compaction. Hence, it is necessary to know the variables responsible for changes in the soil penetration resistance (SPR). The aim of this review is to identify the main factors related to the various equipment used for assessing SPR as a soil physical quality indicator in agriculture. This literature review describes the different types of equipment used and its relationship with SPR. A wide range of procedures, devices, and equipments are available. Much of variability in SPR results is related to the equipment model, cone angle and diameter, and penetration rate. Usually, restrictions to root growth are correlated with SPR values above 2-3 MPa. However, comparisons of SPR values obtained under different soil moisture regimes in the same soil type have provided conflicting results of difficult interpretation. In order to minimize these problems, there is a need for standardization of measurement procedures and interpretation, and/or correction of SPR values according to a soil water content of reference.