69 resultados para valve flat organizzazione videogiochi computer distribuzione digitale steam
em Scielo Saúde Pública - SP
Resumo:
A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.
Resumo:
The results from the need to develop methodologies for performing cost analysis in developing countries, principally in the region of Latin America, were studied. It, furthermore, serves to generate knowledge from an economic evaluation in order to support decision-making related to the organization of health systems, particularly in the efficient use of resources which are allocated for the provision of medical services. Two chronic diseases (breast cancer and cardiac valve disease) and two infections (enteritis and bronchopneumonia) were selected for the study. The results recommend the use of a valid methodology for economic cost analysis of any disease to be studied and the use of this information in the decision-making process.
Resumo:
OBJETIVO: Descrever os achados ao ecocardiograma transesofágico e evolução clínica de portadores de flail mitral valve. MÉTODOS: No período de janeiro/93 a março/97, 1675 pacientes foram submetidos, em nossa instituição, a ecocardiograma transesofágico, sendo que em 35 casos foi feito o diagnóstico de flail mitral valve e, posteriormente, obtida sua evolução clínica. RESULTADOS: A idade dos pacientes variou 12 a 87 anos (média 65±15) e 27 (77%) eram do sexo masculino. O folheto posterior foi o mais acometido (25 pacientes, 71%). O mecanismo do flail foi ruptura de cordoalha tendínea em todos os casos, exceto um, que apresentava importante alongamento e redundância de cordoalha. A etiologia foi prolapso e/ou degeneração mixomatosa em 15 pacientes, degenerativa em 9, isquêmica em 5, reumática em 4 e endocardite em 3. Regurgitação mitral de grau importante ocorreu em 25 (71%) pacientes e moderada em 10 (29%). O tempo médio de acompanhamento foi de 375±395 dias (1 a 1380). Foram submetidos a tratamento clínico 19 pacientes e a tratamento cirúrgico 16, sendo que em todos foi confirmado o diagnóstico transesofágico. O número total de óbitos (hospitalar e pós-hospitalar) foi alto (34%), tanto em pacientes submetidos a tratamento clínico quanto cirúrgico. Entre os sobreviventes, 17 estão em classe funcional (CF) I e 6 em CF II da NYHA. CONCLUSÃO: O diagnóstico de flail mitral valve ao ecocardiograma transesofágico é acurado, permitindo a definição de sua etiologia e mecanismo. A alta mortalidade à época do diagnóstico, provavelmente, se relaciona à gravidade da doença subjacente. Embora os pacientes não operados estejam evoluindo bem, a baixa CF observada nestes pacientes pode ser atribuída ao curto período de seguimento.
Resumo:
This is a report of a nine-year-old boy with both mitral stenosis and regurgitation and extensive endomyocardial fibrosis of the left ventricle. Focus is given to the singularity of the fibrotic process, with an emphasis on the etiopathogenic aspects.
Resumo:
Only rarely do myxomas originate from the mitral valve. This is the report of a 49-year-old woman presenting with congestive heart failure. The diagnosis of an intracardiac tumor involving the anterior cuspid of the mitral valve was made by transesophageal echocardiography. The patient underwent surgery for tumor resection and plasty of the valve was made with reconstruction and preservation of the valve. The diagnosis of myxoma was confirmed by histology. This is the 23rd case of myxoma of the mitral valve reported in the literature.
Resumo:
PURPOSE: To assess anatomical characteristics of the aortic valve, so that they may be useful in diagnostic situations and surgical treatment. METHODS: The study analyzed 100 healthy fixed human hearts; 84% of them obtained from males, 61% of them from Caucasian individuals. The ages of the individuals ranged from 9 to 86 years (mean 30±15.5 years). The characteristics assessed related to age, sex, and race were the following: number and height of the cusps, size of the lunulae, internal and external intercommissural distance, position of the coronary ostium in relation to the aortic valve, position of the ventricular septum in relation to the aortic valve, thickness of the cusps. RESULTS: All hearts assessed had a tricuspidal aortic valve. In regard to the height of the cusps and size of the lunula, the left coronary cusp was larger, followed by the right coronary cusp and the noncoronary cusp. The internal and external intercommissural distances had mean values of 24.6±5.7mm and 19.7±7mm, respectively. In regard to the position of the coronary ostia, in one heart two ostia emerged from the left coronary sinus, and in another, the ostium was supracommissural. The mean diameter of the aorta was 21.8±3.6mm, and there were no significant sexual or racial differences, but the diameter increased progressively with the increase in age. The thickness of the cusps did not show any significant difference in the 3 points assessed. CONCLUSION: The aortic valve annulus did not show a perfect circumference, with some variations in the measurements of the annulus, in the cusps and in the relation with the ventricular septum.
Resumo:
OBJECTIVE - To analyze the immediate and late results of mitral valve repair with quadrangular resection of the posterior leaflet without the use of a prosthetic ring annuloplasty. METHODS - Using this technique, 118 patients with mitral valve prolapse who underwent mitral repair from January '84 through December '96 were studied. Age ranged from 30 to 86 (mean = 59.1±11.8) years and 62.7% were males. An associated surgery was performed in 22% of the patients, and coronary artery bypass graft was the most frequently performed surgery (15 patients - 12.7%). In 20 (16.9%) patients other associated techniques of mitral valve repair were used and shortening of elongated chordae tendineae was the most frequent one (6 patients). RESULTS - Immediate mortality was 0.9% (one patient). Long-term rates for thromboembolism, endocarditis, re-operation and death in the late postoperative period were 0.4%, 0.4%, 1.7% and 2.2% patients/year, respectively. The actuarial curve of survival was 83.8±8.6% over 12 years; survival free from re-operation was 91.8±4.3%, free from endocarditis was 99.2±0.8% and free from thromboembolism was 99.2±0.8%. In the late postoperative period, 93.8% of the patients were in functional class 1 (NYHA), with a complete follow-up in 89.7% of the patients. CONCLUSION - Patients with mitral valve prolapse who undergo mitral valve repair using this technique have a satisfactory prognosis over 12 years.
Resumo:
OBJECTIVE: The aim of this work was the follow-up and evaluation of valve replacement in children under 12 years of age. METHODS: Forty-four children less than 12 years old were underwent valve replacement at INCOR-HCFMUSP between January 1986 and December 1992. Forty (91%) were rheumatic, 39 (88.7%) were in functional classes II or IV, 19 (43.2%) were operated upon on an emergency basis, and 6 (13.6%) had atrial fibrillation. Biological prostheses (BP) were employed in 26 patients (59.1%), and mechanical prostheses (MP) in 18 (40.9%). Mitral valves were replaced in 30 (68.7%), aortic valves in 8 (18.2%), a tricuspid valve in 1 (2.3%), and double (aortic and mitral) valves in 5 (11.4) of the patients. RESULTS: Hospital mortality was of 4.5% (2 cases). The mean follow-up period was 5.8 years. Re-operations occurred in 63.3% of the patients with BP and in 12.5% of those with MP (p=0.002). Infectious endocarditis was present in 26.3% of the BP, but in none of the cases of MP (p=0.049). Thrombosis occurred in 2 (12.5%) and hemorrhage in one (6.5%) of the patients with a MP. Delayed mortality occurred in 5 (11.9%) of the patients over a mean period of 2.6 years; four had had BP and one had a MP (NS). Actuarial survival and re-operation-free curves after 10 years were respectively, 82.5±7.7 (SD)% and 20.6±15.9%. CONCLUSION: Patients with MP required fewer re-operation, had less infectious endocarditis and lower late mortality rates compared with patients with bioprostheses. The former, therefore, appear to be the best valve replacement for pediatric patients.
Resumo:
In this report we describe the twelveth case in the literature of absence of the aortic valve cusps, associated with hypoplastic left-sided heart syndrome in a neonate. Clinical and hemodynamic conditions in our patient resemble the classical features of this syndrome except for a greater development of the ascending aorta and the left ventricular cavity, due to aortic insufficiency. A patch was unsuccessfully inserted at the aortic annulus to exclude the left ventricle from the circulation. In addition the Norwood operation was performed.
Resumo:
A rare association of pulmonary atresia with an intact septum was diagnosed through echocardiography in a fetus 32 weeks of gestational age. The diagnosis was later confirmed by echocardiography of the newborn infant and further on autopsy. The aortic valve was bicuspid with a pressure gradient of 81mmHg, and the right ventricle was hypoplastic, as were the pulmonary trunk and arteries, and the blood flow was totally dependent on the ductus arteriosus.