49 resultados para validation study

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This work was designed to validate the Portuguese version of the Contemplation Ladder, whose purpose is to assess the motivational phase to quit smoking among tobacco users using a telephone service. METHOD: A cross-sectional study was conducted in a nationwide drug use information hotline. In order to assess the convergent validation, the correlation between the Contemplation Ladder and the URICA Scale was calculated, which was previously validated. RESULTS: The study included 271 tobacco users. Statistically significant correlations were found between the Contemplation Ladder scores and the scores of the URICA precontemplation (r=-0.16; p<0.01), action (r=0.15; p<0.01) and maintenance (r=0.18; p<0.01) subscales. The correlation between the URICA Scale compound score and the Contemplation Ladder was also significant (r=0.31; p<0.01). CONCLUSION: The results of our study suggest that the Contemplation Ladder can be an efficient substitute for the URICA scale (whose application lasts at least 20 minutes), without submitting the interviewee to a heavy load of questions. The study presented evidences of convergent validity for the Contemplation Ladder when applied via telephone in tobacco users.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We validated the polymerase chain reaction (PCR) with a composite reference standard in 61 patients clinically suspected of having mucosal leishmaniasis, 36 of which were cases and 25 were non-cases according to this reference standard. Patient classification and test application were carried out independently by two blind observers. One pair of primers was used to amplify a fragment of 120 bp in the conserved region of kDNA and another pair was used to amplify the internal transcript spacers (ITS) rDNA. PCR showed 68.6% (95% CI 59.2-72.6) sensitivity and 92% (95% CI 78.9-97.7) specificity; positive likelihood ratio: 8.6 (95% CI 2.8-31.3) and negative likelihood ratio: 0.3 (95% CI 0.3-0.5), when kDNA molecular target was amplified. The test performed better on sensitivity using this target compared to the ITS rDNA molecular target which showed 40% (95% CI 31.5-42.3) sensitivity and 96% (95% CI 84.1-99.3) specificity; positive likelihood ratio: 10 (95% CI 2.0-58.8) and negative likelihood ratio: 0.6 (95% CI 0.6-0.8). The inter-observer agreement was excellent for both tests. Based upon results obtained and due to low performance of conventional methods for diagnosing mucosal leishmaniasis, we consider PCR with kDNA as molecular target is a useful diagnostic test and the ITS rDNA molecular target is useful when the aim is to identify species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To validate assistive technology for visually impaired women to learn how to use the female condom. METHOD a methodological development study conducted on a web page, with data collection between May and October 2012. Participants were 14 judges; seven judges in sexual and reproductive health (1st stage) and seven in special education (2nd stage). RESULTS All items have reached the adopted parameter of 70% agreement. In Stage 1 new materials were added to represent the cervix, and instructions that must be heard twice were included in the 2nd stage. CONCLUSION The technology has been validated and is appropriate for its objectives, structure / presentation and relevance. It is an innovative, low cost and valid instrument for promoting health and one which may help women with visual disabilities to use the female condom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiation balance is the fraction of incident solar radiation upon earth surface which is available to be used in several natural processes, such as biological metabolism, water loss by vegetated surfaces, variation of temperature in farming systems and organic decomposition. The present study aimed to assess and validate the performance of two estimation models for Rn in Ponta Grossa city, Paraná State, Brazil. To this end, during the period of 04/01/2008 to 04/30/2011, from radiometric data collected by an automatic weather station set at the Experimental Station, of the State University of Ponta Grossa. We performed a linear regression study by confrontation between measurements made through radiometric balance and Rn estimates obtained from Brunt classical method, and the proposed method. Both models showed excellent performance and were confirmed by the statistical parameters applied. However, the alternative method has the advantage of requiring only global solar radiation values, temperature, and relative humidity.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION: Leptospirosis is often mistaken for other acute febrile illnesses because of its nonspecific presentation. Bacteriologic, serologic, and molecular methods have several limitations for early diagnosis: technical complexity, low availability, low sensitivity in early disease, or high cost. This study aimed to validate a case definition, based on simple clinical and laboratory tests, that is intended for bedside diagnosis of leptospirosis among hospitalized patients. METHODS: Adult patients, admitted to two reference hospitals in Recife, Brazil, with a febrile illness of less than 21 days and with a clinical suspicion of leptospirosis, were included to test a case definition comprising ten clinical and laboratory criteria. Leptospirosis was confirmed or excluded by a composite reference standard (microscopic agglutination test, ELISA, and blood culture). Test properties were determined for each cutoff number of the criteria from the case definition. RESULTS: Ninety seven patients were included; 75 had confirmed leptospirosis and 22 did not. Mean number of criteria from the case definition that were fulfilled was 7.8±1.2 for confirmed leptospirosis and 5.9±1.5 for non-leptospirosis patients (p<0.0001). Best sensitivity (85.3%) and specificity (68.2%) combination was found with a cutoff of 7 or more criteria, reaching positive and negative predictive values of 90.1% and 57.7%, respectively; accuracy was 81.4%. CONCLUSIONS: The case definition, for a cutoff of at least 7 criteria, reached average sensitivity and specificity, but with a high positive predictive value. Its simplicity and low cost make it useful for rapid bedside leptospirosis diagnosis in Brazilian hospitalized patients with acute severe febrile disease.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To assess the internal consistency of the measurements of the Self-Reporting Questionnaire (SRQ-20) in different occupational groups. METHODS A validation study was conducted with data from four surveys with groups of workers, using similar methods. A total of 9,959 workers were studied. In all surveys, the common mental disorders were assessed via SRQ-20. The internal consistency considered the items belonging to dimensions extracted by tetrachoric factor analysis for each study. Item homogeneity assessment compared estimates of Cronbach’s alpha (KD-20), the alpha applied to a tetrachoric correlation matrix and stratified Cronbach’s alpha. RESULTS The SRQ-20 dimensions showed adequate values, considering the reference parameters. The internal consistency of the instrument items, assessed by stratified Cronbach’s alpha, was high (> 0.80) in the four studies. CONCLUSIONS The SRQ-20 showed good internal consistency in the professional categories evaluated. However, there is still a need for studies using alternative methods and additional information able to refine the accuracy of latent variable measurement instruments, as in the case of common mental disorders.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study aimed at analyzing nipple trauma resulted from breastfeeding based on dermatological approach. Two integrative reviews of literature were conducted, the first related to definitions, classification and evaluation methods of nipple trauma and another about validation studies related to this theme. In the first part were included 20 studies and only one third defined nipple trauma, more than half did not defined the nipple’s injuries reported, and each author showed a particular way to assess the injuries, without consensus. In the second integrative review, no validation study or algorithm related to nipple trauma resulted from breastfeeding was found. This fact demonstrated that the nipple’s injuries mentioned in the first review did not go through validation studies, justifying the lack of consensus identified as far as definition, classification and assessment methods of nipple trauma.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The evaluation of uncertainty associated with an analytic result is an essential part of the measurement process. Recently, several approaches to evaluate the uncertainty in measurement have been developed. Here, the gas chromatography assay uncertainty for natural gas is compared by some of these approaches: the guide to the expression of uncertainty in measurement (GUM) approach, top-down approach (reproducibility estimate from an inter-laboratory study), Barwick & Ellison (data from validation), study of variability and fuzzy approach. The comparison shows that GUM, Barwick & Ellison and fuzzy approaches lead to comparable uncertainty evaluations, which does not happen with the top-down approach and study of variability by the absence of data normality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A validation study of an UV spectrophotometric method was conducted for quantitative analysis of benznidazol (BZN) in a lipid. The analytical determinations were performed at 315 nm at 25 ºC. The emulsion components did not interfere on drug analyses, demonstrating the specificity of the methodology. A good linearity (r = 0.99995) and precision (RSD < 5.0%) for intra and inter-day studies, including the reproducibility test were observed. The accuracy ranged of 102.1 + 2.8 e 103.8 + 1.7%. The statistical analysis demonstrates a linear, precise, accurate and robust method for BZN quantification from the lipid emulsion system.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: Testing the psychometric properties of the Portuguese version of the Practice Environment Scale of the Nursing Work Index. Method: A descriptive, analytical and cross-sectional study, for the cross-cultural adaptation and validation of the psychometric properties of the scale. The study participants were 236 nurses from two hospitals in the regions of Lisbon and Vale do Tejo. Results: The 0.92 Cronbach’s alpha was obtained for overall reliability and support of a five-dimension structure. Conclusion: The excellent quality of adjustment of analysis confirms the validity of the adapted version to hospital care settings, although there was no total coincidence of items in the five dimensions


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study validated a high performance liquid chromatography (HPLC) method for the quantitative evaluation of quercetin in topical emulsions. The method was linear within 0.05 - 200 μg/mL range with a correlation coefficient of 0.9997, and without interference in the quercetin peak. The detection and quantitation limits were 18 and 29 ng/mL, respectively. The intra- and inter-assay precisions presented R.S.D. values lower than 2%. An average of 93% and 94% of quercetin was recovered for non-ionic and anionic emulsions, respectively. The raw material and anionic emulsion, but not non-ionic emulsion, were stable in all storage conditions for one year. The method reported is a fast and reliable HPLC technique useful for quercetin determination in topical emulsions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The increasing proportion of older adults in the general population and the specific characteristics of this age group show the need for the development of specific instruments to measure quality of life in older adults. The study aimed at describing the development and validation of the Portuguese version of the World Health Organization Quality of Life for Older Persons (WHOQOL-OLD) module. METHODS: The WHOQOL-OLD instrument was administered in a sample of 424 older adults in the city of Porto Alegre, Southern Brazil, in 2005. The questionnaire comprises 24 items divided into six facets: sensory abilities; autonomy; past, present and future activities; social participation; death and dying; and intimacy. Besides the WHOQOL-OLD module, the WHOQOL-BREF, BDI and BHS instruments were also applied. The instrument's internal consistency was assessed using Cronbach's alpha coefficient. RESULTS: The instrument showed adequate internal consistency (Cronbach's coefficients ranging from 0.71 to 0.88), discriminant validity (p<0.01), concurrent validity (correlation coefficients ranging from -0.61 to -0.50) and test-retest reliability (correlation coefficients ranging from 0.58 to 0.82). Findings concerning criterion validity need further studies. CONCLUSIONS: The WHOQOL-Old module is a useful alternative with good psychometric performance in the investigation of quality of life in older adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to validate the 14C-urea breath test for use in diagnosis of Helicobacter pylori infection. Thirty H. pylori positive patients, based on histologic test and thirty H. pylori negative patients by histology and anti-H. pylori IgG entered the study. Fasting patients drank 5 uCi of 14C-urea in 20 ml of water. Breath samples were collected at 0, 5, 10, 15, 20 and 30 min. The difference of cpm values between the two groups was significant at all the time intervals, besides time 0 (p<0.0001). At 20 min, the test gave 100% sensitivity and specificity with a cut-off value of 562 cpm. Females were higher expirers than males (p=0.005). 14C-urea breath test is highly accurate for Helicobacter pylori diagnosis. It is fast, simple and should be the non-invasive test used after treating Helicobacter pylori infection.