5 resultados para temperature measurement
em Scielo Saúde Pública - SP
Resumo:
Textile manufacture occupies a prominent place in the national economy. Because of its importance researches have been made on the development of new materials, equipment and methods used in the production process. The cutting of textiles starts in the basic stage, to be followed by the process of the making of clothes and other articles. In the hot cutting of fabric, one of the variables of great importance in the control of the process is the contact temperature between the tool and the fabric. This work presents a technique for the measurement of the temperature based on the processing of infrared images. With this purpose, it was developed a system which is composed of an infrared camera, a framegrabber PC board and a software which analyses the punctual temperature in the cut area enabling the operator to achieve the necessary control of other variables involved in the process.
Resumo:
This work describes the evolution of temperature measurement in the last four centuries using thermometers based on the thermal expansion of liquids such as ethyl alcohol and mercury. The concept of temperature was strongly dependent on the researcher and there was no systematic temperature scale for universal use. The precursor of the common thermometer was the thermoscope, probably invented at the end of the XVIth century. In the XVIIIth century the instrument was greatly improved and several thermometric scales were proposed some of which have been in use until now. These scales were based on arbitrary points. Mercury and ethyl alcohol were the most employed thermometric fluids. In the XIXth century, the concept of absolute zero was a great advance in this field. The most important contribution during the XXth century was the establishment of international temperature scales. The design of the thermometer has been essentially the same along the last 300 years, but many models were proposed for industrial and research purposes. Its association with the densimeter was of great importance for control of industrial chemical processes and also for teaching purposes in the past. Nowadays, there is a clear tendency to replace mercury-based thermometers by electronic digital models. Thermochemistry is the natural relationship between temperature and chemistry.
Resumo:
Sap flow could be used as physiological parameter to assist irrigation of screen house citrus nursery trees by continuous water consumption estimation. Herein we report a first set of results indicating the potential use of the heat dissipation method for sap flow measurement in containerized citrus nursery trees. 'Valencia' sweet orange [Citrus sinensis (L.) Osbeck] budded on 'Rangpur' lime (Citrus limonia Osbeck) was evaluated for 30 days during summer. Heat dissipation probes and thermocouple sensors were constructed with low-cost and easily available materials in order to improve accessibility of the method. Sap flow showed high correlation to air temperature inside the screen house. However, errors due to natural thermal gradient and plant tissue injuries affected measurement precision. Transpiration estimated by sap flow measurement was four times higher than gravimetric measurement. Improved micro-probes, adequate method calibration, and non-toxic insulating materials should be further investigated.
Resumo:
Pressure-driven and temperature-driven transitions of two thermoresponsive polymers, poly(N-isopropylacrylamide) (pNIPAM) and poly(N-vinylisobutyramide) (pNVIBA)), in both a soluble linear polymer form and a cross-linked hydro-gel form, were examined by a dynamic light-scattering method and direct microscopic observation, respectively. Their behavior was compared with that of protein systems. Changes in some characteristic parameters in the time-intensity correlation functions of dynamic light-scattering measurement of aqueous solutions of pNIPAM at various pressures and temperatures showed no essential differences during temperature and pressure scanning and, as a whole, the motions of polymers in aqueous solutions were similar in two types of transitions until chain shrinkage occurred. The gels (cross-linked polymer gels) prepared from the thermoresponsive polymers also showed similar volume transitions responding to the pressure and temperature increase. In temperature transitions, however, gels showed drastic volume shrinkage with loss of transparency, while pressure-induced transition showed a slow recovery of transparency while keeping the size, after first transient drastic volume shrinkage with loss of transparency. At a temperature slightly higher than the transition under atmospheric temperature, so-called reentry of the volume change and recovery of the transparency were observed during the pressure-increasing process, which implies much smaller aggregation or non-aggregated collapsed polymer chains in the gel at higher pressures, indicating a certain mechanistic difference of the dehydration processes induced by temperature and pressure.
Resumo:
Both epidural and general anesthesia can impair thermoregulatory mechanisms during surgery. However, there is lack of information about the effects of different methods of anesthesia on newborn temperature. The purpose of this study was to determine whether there are differences in newborn rectal temperature related to type of anesthesia. Sixty-three pregnant women were randomly assigned to receive general or epidural anesthesia. Maternal core temperature was measured three times with a rectal probe just before anesthesia, at the beginning of surgery and at delivery. In addition, umbilical vein blood was sampled for pH. The rectal temperatures of the babies were recorded immediately after delivery, and Apgar scores were determined 1, 5, and 10 min after birth. The duration of anesthesia and the volume of intravenous fluid given during the procedure (833 ± 144 vs 420 ± 215 mL) were significantly higher in the epidural group than in the general anesthesia group (P < 0.0001). Maternal rectal temperatures were not different in both groups at all measurements. In contrast, newborn rectal temperatures were lower in the epidural anesthesia group than in the general anesthesia group (37.4 ± 0.3 vs 37.6 ± 0.3°C; P < 0.05) immediately after birth. Furthermore, the umbilical vein pH value (7.31 ± 0.05 vs 7.33 ± 0.01; P < 0.05) and Apgar scores at the 1st-min measurement (8.0 ± 0.9 vs 8.5 ± 0.7; P < 0.05) were lower in the epidural anesthesia group than in the general anesthesia group. Since epidural anesthesia requires more iv fluid infusion and a longer time for cesarean section, it involves a risk of a mild temperature reduction for the baby which, however, did not reach the limits of hypothermia.