43 resultados para standard batch algorithms
em Scielo Saúde Pública - SP
Resumo:
The application of multivariate calibration techniques to multicomponent analysis by UV-VIS molecular absorption spectrometry is a powerful tool for simultaneous determination of several chemical species. However, when this methodology is accomplished manually, it is slow and laborious, consumes high amounts of reagents and samples, is susceptible to contaminations and presents a high operational cost. To overcome these drawbacks, a flow-batch analyser is proposed in this work. This analyser was developed for automatic preparation of standard calibration and test (or validation) mixtures. It was applied to the simultaneous determination of Cu2+, Mn2+ and Zn2+ in polyvitaminic and polymineral pharmaceutical formulations, using 4-(2-piridilazo) resorcinol as reagent and a UV-VIS spectrophotometer with a photodiode array detector. The results obtained with the proposed system are in good agreement with those obtained by flame atomic absorption spectrometry, which was employed as reference method. With the proposed analyser, the preparation of calibration and test mixtures can be accomplished about four hours, while the manual procedure requires at least two days. Moreover, it consumes smaller amounts of reagents and samples than the manual procedure. After the preparation of calibration and test mixtures, 60 samples h-1 can be carried out with the proposed flow-batch analyser.
Resumo:
Our objective is to evaluate the accuracy of three algorithms in differentiating the origins of outflow tract ventricular arrhythmias (OTVAs). This study involved 110 consecutive patients with OTVAs for whom a standard 12-lead surface electrocardiogram (ECG) showed typical left bundle branch block morphology with an inferior axis. All the ECG tracings were retrospectively analyzed using the following three recently published ECG algorithms: 1) the transitional zone (TZ) index, 2) the V2 transition ratio, and 3) V2 R wave duration and R/S wave amplitude indices. Considering all patients, the V2 transition ratio had the highest sensitivity (92.3%), while the R wave duration and R/S wave amplitude indices in V2 had the highest specificity (93.9%). The latter finding had a maximal area under the ROC curve of 0.925. In patients with left ventricular (LV) rotation, the V2 transition ratio had the highest sensitivity (94.1%), while the R wave duration and R/S wave amplitude indices in V2 had the highest specificity (87.5%). The former finding had a maximal area under the ROC curve of 0.892. All three published ECG algorithms are effective in differentiating the origin of OTVAs, while the V2 transition ratio, and the V2 R wave duration and R/S wave amplitude indices are the most sensitive and specific algorithms, respectively. Amongst all of the patients, the V2 R wave duration and R/S wave amplitude algorithm had the maximal area under the ROC curve, but in patients with LV rotation the V2 transition ratio algorithm had the maximum area under the ROC curve.
Resumo:
ABSTRACT OBJECTIVE : To evaluate the validity and reliability of the Questionnaire for Compliance with Standard Precaution for nurses. METHODS : This methodological study was conducted with 121 nurses from health care facilities in Sao Paulo's countryside, who were represented by two high-complexity and by three average-complexity health care facilities. Internal consistency was calculated using Cronbach's alpha and stability was calculated by the intraclass correlation coefficient, through test-retest. Convergent, discriminant, and known-groups construct validity techniques were conducted. RESULTS : The questionnaire was found to be reliable (Cronbach's alpha: 0.80; intraclass correlation coefficient: (0.97) In regards to the convergent and discriminant construct validity, strong correlation was found between compliance to standard precautions, the perception of a safe environment, and the smaller perception of obstacles to follow such precautions (r = 0.614 and r = 0.537, respectively). The nurses who were trained on the standard precautions and worked on the health care facilities of higher complexity were shown to comply more (p = 0.028 and p = 0.006, respectively). CONCLUSIONS : The Brazilian version of the Questionnaire for Compliance with Standard Precaution was shown to be valid and reliable. Further investigation must be conducted with nurse samples that are more representative of the Brazilian reality. The use of the questionnaire may support the creation of educational measures considering the possible gaps that can be identified, focusing on the workers' health and on the patients' safety.
Resumo:
To determine the rabies antibody level of twenty-four hyperimmune equine sera, Standard Mouse Neutralization (SMN) and Couterimmunoelectrophoresis (CIE) tests were carried out, both at the Instituto Butantan (IB) and Instituto Panamericano de Protección de Alimentos y Zoonosis (INPPAZ). Statistical analysis has shown a correlation (r) of 0.9317 between the SMN and CIE performed at the IB, while at the INPPAZ it scored 0.974. Comparison of CIE data of both laboratories yielded a correlation of 0.845. The CIE technique has shown to be as sensitive and efficient as the SMN in titrating antirabies hyperimmune equine sera. Based on CIE results, a simple, rapid and inexpensive technique, tilers of sera antibody can be reliably estimated in SMN test.
Resumo:
For the purpose of research a large quantity of anti-measles IgG working reference serum was needed. A pool of sera from five teenagers was prepared and named Alexandre Herculano (AH). In order to calibrate the AH serum, 18 EIA assays were performed testing in parallel AH and the 2nd International Standard 1990, Anti-Measles Antibody, 66/202 (IS) in a range of dilutions (from 1/50 to 1/25600). A method which compared parallel lines resulting from the graphic representation of the results of laboratory tests was used to estimate the power of AH relative to IS. A computer programme written by one of the authors was used to analyze the data and make potency estimates. Another method of analysis was used, comparing logistic curves relating serum concentrations with optical density by EIA. For that purpose an existing computer programme (WRANL) was used. The potency of AH relative to IS, by either method, was estimated to be 2.4. As IS has 5000 milli international units (mIU) of anti-measles IgG per millilitre (ml), we concluded that AH has 12000 mIU/ml.
Resumo:
The RID assay is one of the in vitro methods used for in-process control in the production of rabies vaccines for veterinary use. It has been shown to be very useful for determining antigen concentration in the final bulk product. The work presented in this paper, including the production and standardization of candidate standard reagents for use in the Radial Immunodiffusion Assay (RID) was carried out at the Pan American Institute for Food Protection and Zoonoses (INPPAZ/PAHO/WHO). The study was completed with the cooperation of the Faculty of Veterinary Sciences, National University of La Plata (NULP), Argentina, where the validation of the proposed standards and the quality control of samples from 28 different batches of rabies vaccines produced with Pasteur strain rabies virus (PV) in BHK cells were performed. The activity of the vaccines was determined by in vivo (NIH) and in vitro (RID)assays. The results of the candidate reagents for the reagent standardization tests showed stability, sensitivity and reproducibility. The Relative Potency the 1.2 between the problem vaccines and the reference vaccine was estimated by variance and regression analysis. The results of our validation study show that the INPPAZ (PAHO/WHO) is capable of producing and distributing the above-mentioned standard reagents, as well as of providing support for the incorporation of the RID technique (sensitive, rapid and inexpensive) to the laboratories that manufacture rabies vaccines in Latin America and the Caribbean.
Resumo:
OBJECTIVE - The aim of our study was to assess the profile of a wrist monitor, the Omron Model HEM-608, compared with the indirect method for blood pressure measurement. METHODS - Our study population consisted of 100 subjects, 29 being normotensive and 71 being hypertensive. Participants had their blood pressure checked 8 times with alternate techniques, 4 by the indirect method and 4 with the Omron wrist monitor. The validation criteria used to test this device were based on the internationally recognized protocols. RESULTS - Our data showed that the Omron HEM-608 reached a classification B for systolic and A for diastolic blood pressure, according to the one protocol. The mean differences between blood pressure values obtained with each of the methods were -2.3 +7.9mmHg for systolic and 0.97+5.5mmHg for diastolic blood pressure. Therefore, we considered this type of device approved according to the criteria selected. CONCLUSION - Our study leads us to conclude that this wrist monitor is not only easy to use, but also produces results very similar to those obtained by the standard indirect method.
Resumo:
Background: The use of three-dimensional rotational angiography (3D-RA) to assess patients with congenital heart diseases appears to be a promising technique despite the scarce literature available. Objectives: The objective of this study was to describe our initial experience with 3D-RA and to compare its radiation dose to that of standard two-dimensional angiography (2D-SA). Methods: Between September 2011 and April 2012, 18 patients underwent simultaneous 3D-RA and 2D-SA during diagnostic cardiac catheterization. Radiation dose was assessed using the dose-area-product (DAP). Results: The median patient age and weight were 12.5 years and 47.5 Kg, respectively. The median DAP of each 3D-RA acquisition was 1093µGy.m2 and 190µGy.m2 for each 2D-SA acquisition (p<0.01). In patients weighing more than 45Kg (n=7), this difference was attenuated but still significant (1525 µGy.m2 vs.413µGy.m2, p=0.01). No difference was found between one 3D-RA and three 2D-SA (1525µGy.m2 vs.1238 µGy.m2, p = 0.575) in this population. This difference was significantly higher in patients weighing less than 45Kg (n=9) (713µGy.m2 vs.81µGy.m2, P = 0.008), even when comparing one 3D-RA with three 2D-SA (242µGy.m2, respectively, p<0.008). 3D-RA was extremely useful for the assessment of conduits of univentricular hearts, tortuous branches of the pulmonary artery, and aorta relative to 2D-SA acquisitions. Conclusions: The radiation dose of 3D-RA used in our institution was higher than those previously reported in the literature and this difference was more evident in children. This type of assessment is of paramount importance when starting to perform 3D-RA.
Resumo:
During an epidemiological survey of acute respiratory infection in Rio de Janeiro, among 208 adenovirus isolates, we found two strains that we were not able, by a standard neutralization procedure, to distinguish between type 3 or 7. However, DNA restriction pattern for the two strains with different enzymes were analyzed and showed a typical Ad3h profile. Using a cross-neutralization test in which both Ad3p and Ad7p antisera were used in different concentration against 100 TCID50 of each adenovirus standard and both isolates, we were able to confirm that the two isolates belong to serotype 3. An hemagglutination inhibition test also corroborated the identification of both strains as adenovirus type 3. Comparing Ad3h and Ad3p genome, we observed 16 different restriction enzyme sites, three of which were located in genomic regions encoding polypeptides involved in neutralization sites
Resumo:
A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.
Resumo:
The aim of this work was to evaluate a dot-enzyme-linked immunosorbent assay (dot-ELISA) using excretory-secretory antigens from the larval stages of Toxocara canis for the diagnosis of toxocariasis. A secondary aim was to establish the optimal conditions for its use in an area with a high prevalence of human T. canis infection. The dot-ELISA test was standardised using different concentrations of the antigen fixed on nitrocellulose paper strips and increasing dilutions of the serum and conjugate. Both the dot-ELISA and standard ELISA methods were tested in parallel with the same batch of sera from controls and from individuals living in the problem area. The best results were obtained with 1.33 µg/mL of antigen, dilutions of 1/80 for the samples and controls and a dilution of 1/5,000 for the anti-human IgG-peroxidase conjugate. All steps of the procedure were performed at room temperature. The coincidence between ELISA and dot-ELISA was 85% and the kappa index was 0.72. The dot-ELISA test described here is rapid, easy to perform and does not require expensive equipment. Thus, this test is suitable for the serological diagnosis of human T. canis infection in field surveys and in the primary health care centres of endemic regions.
Resumo:
Hepatitis D virus (HDV) is endemic in the Amazon Region and its pathophysiology is the most severe among viral hepatitis. Treatment is performed with pegylated interferon and the immune response appears to be important for infection control. HDV patients were studied: untreated and polymerase chain reaction (PCR) positive (n = 9), anti-HDV positive and PCR negative (n = 8), and responders to treatment (n = 12). The cytokines, interleukin (IL)-2 (p = 0.0008) and IL-12 (p = 0.02) were differentially expressed among the groups and were also correlated (p = 0.0143). Future studies will be conducted with patients at different stages of treatment, associating the viral load with serum cytokines produced, thereby attempting to establish a prognostic indicator of the infection.
Resumo:
The purpose of this study was to assess the knowledge and attitude of health care professionals regarding their use of universal precaution measures at a public emergency service. The study also aimed to assess the rates of occupational accidents involving biological substances among those workers. This study was performed with 238 workers, from June to November 2006, using univariate and multivariate analysis. The chance of not adopting precaution measures was 20.7 (95% CI: 5.68 - 75.14) times greater among drivers compared to physicians. No significant association was found between adopting universal precaution measures. The occupational accident rate was 20.6% (40.8% involving sharp-edged objects). The risk of physicians having an occupational accident was 2.7(95% CI: 1.05 - 7.09) times higher than that of drivers. The fact that a staff member had adequate knowledge about universal precaution measures was insufficient to foster compatible attitudes towards reducing the risk of transmitting infectious agents and causing occupational accidents.
Resumo:
OBJECTIVE Evaluate and correlate individual, work-related and organizational factors that influence adherence to standard precautions among nursing professionals of psychiatric hospitals in São Paulo. METHOD An exploratory cross-sectional study conducted with 35 nursing professionals, using the assessment tool for adherence to standard precautions through the Likert scale, ranging from 1 to 5. RESULTS Knowledge of the precautions received a high score (4.69); adherence received (3.86) and obstacles (3.78), while intermediaries and the scales of organizational factors received low scores (2.61). There was a strong correlation between the magnitude adherence scale and the personal protective equipment availability (r = 0.643; p = 0.000). The training scale for prevention of HIV exposure (p = 0.007) was statistically different between the nurses and nursing assistants. CONCLUSION The organizational factors negatively contributed to adherence to standard precautions, indicating that psychiatric institutions lack safe working conditions, ongoing training and management actions to control infections.