6 resultados para quality-delivery mode

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate changes to the pelvic floor of primiparous women with different delivery modes, using three-dimensional ultrasound. METHODS: A prospective cross-sectional study on 35 primiparae divided into groups according to the delivery mode: elective cesarean delivery (n=10), vaginal delivery (n=16), and forceps delivery (n=9). Three-dimensional ultrasound on the pelvic floor was performed on the second postpartum day with the patient in a resting position. A convex volumetric transducer (RAB4-8L) was used, in contact with the large labia, with the patient in the gynecological position. Biometric measurements of the urogenital hiatus were taken in the axial plane on images in the rendering mode, in order to assess the area, anteroposterior and transverse diameters, average thickness, and avulsion of the levator ani muscle. Differences between groups were evaluated by determining the mean differences and their respective 95% confidence intervals. The proportions of levator ani muscle avulsion were compared between elective cesarean section and vaginal birth using Fisher's exact test. RESULTS: The mean areas of the urogenital hiatus in the cases of vaginal and forceps deliveries were 17.0 and 20.1 cm², respectively, versus 12.4 cm² in the Control Group (elective cesarean). Avulsion of the levator ani muscle was observed in women who underwent vaginal delivery (3/25), however there was no statistically significant difference between cesarean section and vaginal delivery groups (p=0.5). CONCLUSION: Transperineal three-dimensional ultrasound was useful for assessing the pelvic floor of primiparous women, by allowing pelvic morphological changes to be differentiated according to the delivery mode.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To evaluate the obstetric and perinatal outcomes evolution of triplet pregnancies.METHODS: A prospective observational study was conducted in triplet pregnancies delivered over 16 years in a tertiary obstetric center with differentiated perinatal support. Evaluation of demographic factors, obstetric complications, gestational age at delivery, mode of delivery, birth weight and immediate newborn outcome were done over a 16 years period. A global characterization of the sample was performed considering the listed parameters. Variables were categorized in three groups according to year of occurrence: 1996-2000, 2001-2006, 2007-2011, and all parameters were compared.RESULTS: Of the 33 triplets included, 72.7% resulted from induced pregnancies. All except one patient received prenatal corticosteroids and five received tocolytics. All women delivered prenatally and no significant differences were seen in the mean gestational age at delivery or birth weight towards time. There were three intrauterine fetal deaths. Neonatal immediate outcomes were not significantly different over the years.CONCLUSION: Despite remarkable progresses in perinatal and neonatal cares, no noticeable impact in triplet gestations' outcomes was seen, sustaining that triplets should be avoided due to their great risk of prematurity and neonatal morbidities, either by limiting the numbers of embryos transferred or by fetal reduction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To compare obstetric outcomes of induced preterm twin births (under 32 weeks gestation) with those spontaneously conceived. METHODS: Prospective study of twin pregnancies (25 induced and 157 spontaneously conceived) developed over a period of 16 years in a tertiary obstetric center. Demographic factors, obstetric complications, gestational age at delivery, mode of delivery, birth weight and immediate newborn outcome were compared. RESULTS: The analysis of obstetrical complications concerning urinary or other infections, hypertensive disorders of pregnancy, gestational diabetes, fetal malformations, intrauterine fetal death, intrauterine growth restriction and intrauterine discordant growth reveal no significant statistical differences between the two groups. First trimester bleeding was higher in the induced group (24 versus 8.3%, p=0.029). The cesarean delivery rate was 52.2% in spontaneous gestations and 64% in induced gestations. Gestational age at delivery, birth weight, Apgar scores at first and fifth minutes, admissions to Neonatal Intensive Care Unit and puerperal complications show no statistically significant differences between the two groups. These results were independent of chorionicity and induction method. CONCLUSION: The mode of conception did not influence obstetric and neonatal outcomes. Although induced pregnancies have higher risk of first trimester bleeding, significant differences were not observed regarding other obstetric and puerperal complications and neonatal results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine changes in the incidence of vaginal deliveries, cesarean sections, and forceps deliveries and their potential association with fetal, early neonatal, and perinatal mortality rates over time. METHODS: A retrospective study was carried out and the occurrence of deliveries supervised by university services between January 1991 and December 2000 was determined. Data regarding fetal, early neonatal, and perinatal deaths were assessed using obstetric and pediatric records and autopsy reports. RESULTS: Of a total of 33,360 deliveries, the incidence of vaginal deliveries, cesarean sections, and forceps deliveries was relatively steady (around 60, 30, and 10%, respectively) while, at the same time, there was a marked reduction in fetal mortality (from 33.3 to 13.0‰), early neonatal mortality (from 30.6 to 9.0‰), and perinatal mortality (from 56.4 to 19.3‰). CONCLUSIONS: The marked reduction in perinatal mortality rates seen during the study period without an increase in cesarean sections indicates that the decrease in perinatal mortality was not impacted by cesarean section rates. The plausible hypothesis seems to be that the reduction in perinatal mortality of deliveries performed under the supervision of university services was more likely to be associated with better neonatal care rather than the mode of delivery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Failure Mode and Effect Analysis (FMEA) was applied for risk assessment of confectionary manufacturing, in whichthe traditional methods and equipment were intensively used in the production. Potential failure modes and effects as well as their possible causes were identified in the process flow. Processing stages that involve intensive handling of food by workers had the highest risk priority numbers (RPN = 216 and 189), followed by chemical contamination risks in different stages of the process. The application of corrective actions substantially reduced the RPN (risk priority number) values. Therefore, the implementation of FMEA (The Failure Mode and Effect Analysis) model in confectionary manufacturing improved the safety and quality of the final products.