77 resultados para pressure drop

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of the present work is the experimental determination of pressure drop coefficients (loss coefficients) for elliptic and circular sections in one, two and three-row arrangements of plate fin and tube heat exchangers. The experiments permitted to correlate the dimensionless loss coefficient with the flow Reynolds number in the rectangular channel formed by the plate fins. The experimental technique consisted of the measurement of the longitudinal pressure distribution along the flow channel, for several values of air mass flow rate. The total number of data runs, each one characterized by the flow Reynolds number, was 216. The present geometry is used in compact heat exchangers for air conditioning systems, heaters, radiators, and others. Also, it is verified the influence of the utilization of elliptic tubes, instead of circular ones, in the pressure drop. The measurements were performed for Reynolds numbers ranging from 200 to 1900.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experiments were performed to determine average heat transfer coefficients and friction factors for turbulent flow through annular ducts with pin fins. The measurements were carried out by means of a double-pipe heat exchanger. The total number of pins attached to the inner wall of the annular region was 560. The working fluids were air, flowing in the annular channel, and water through the inner circular tube. The average heat transfer coefficients of the pinned air-side were obtained from the experimental determination of the overall heat transfer coefficients of the heat exchanger and from the knowledge of the average heat transfer coefficients of the circular pipe (water-side), which could be found in the pertinent literature. To attain fully developed conditions, the heat exchanger was built with additional lengths before and after the test section. The inner circular duct of the heat exchanger and the pin fins were made of brass. Due to the high thermal conductivity of the brass, the small tube thickness and water temperature variation, the surface of the internal tube was practically isothermal. The external tube was made of an industrial plastic which was insulated from the environment by means of a glass wool batt. In this manner, the outer surface of the annular channel can be considered adiabatic. The results are presented in dimensionless forms, in terms of average Nusselt numbers and friction factors as functions of the flow Reynolds number, ranging from 13,000 to 80,000. The pin fin efficiency, which depends on the heat transfer coefficient, is also determined as a function of dimensionless parameters. A comparison of the present results with those for smooth sections (without pins) is also presented. The purpose of such a comparison is to study the influence of the presence of the pins on the pressure drop and heat transfer rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fuel elements of PWR type nuclear reactors consist of rod bundles, arranged in a square array, and held by spacer grids. The coolant flows, mainly, axially along the rods. Although such elements are laterally open, experiments are performed in closed type test sections, originating the appearance of subchannels with different geometries. In the present work, utilizing a test section of two bundles of 4x4 pins each, experiments were performed to determine the friction and the grid drag coefficients for the different subchannels and to observe the effect of the grids in the crossflow, in cases of inlet flow maldistribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experimental apparatus for the study of core annular flows of heavy oil and water at room temperature has been set up and tested at laboratory scale. The test section consists of a 2.75 cm ID galvanized steel pipe. Tap water and a heavy oil (17.6 Pa.s; 963 kg/m³) were used. Pressure drop in a vertical upward test section was accurately measured for oil flow rates in the range 0.297 - 1.045 l/s and water flow rates ranging from 0.063 to 0.315 l/s. The oil-water input ratio was in the range 1-14. The measured pressure drop comprises gravitational and frictional parts. The gravitational pressure drop was expressed in terms of the volumetric fraction of the core, which was determined from a correlation developed by Bannwart (1998b). The existence of an optimum water-oil input ratio for each oil flow rate was observed in the range 0.07 - 0.5. The frictional pressure drop was modeled to account for both hydrodynamic and net buoyancy effects on the core. The model was adjusted to fit our data and shows excellent agreement with data from another source (Bai, 1995).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJECTIVE: To assess the association between microalbuminuria with ambulatory blood pressure monitoring in normotensive individuals with insulin-dependent diabetes mellitus. METHODS: Thirty-seven patients underwent determination of the rate of urinary excretion of albumin through radioimmunoassay and ambulatory blood pressure monitoring. Their mean age was 26.5±6.7 years, and the mean duration of their disease was 8 (1-34) years. Microalbuminuria was defined as urinary excretion of albumin > or = 20 and <200µg/min in at least 2 out of 3 urine samples. RESULTS: Nine (24.3%) patients were microalbuminuric. Ambulatory blood pressure monitoring in the microalbuminuric patients had higher mean pressure values, mainly the systolic pressure, during sleep as compared with that in the normoalbuminuric patients (120.1±8.3 vs 110.8±7.1 mmHg; p=0.007). The pressure load was higher in the microalbuminuric individuals, mainly the systolic pressure load during wakefulness [6.3 (2.9-45.9) vs 1.6 (0-16%); p=0.001]. This was the variable that better correlated with the urinary excretion of albumin (rS=0.61; p<0.001). Systolic pressure load >50% and diastolic pressure load > 30% during sleep was associated with microalbuminuria (p=0.008). The pressure drop during sleep did not differ between the groups. CONCLUSION: Microalbuminuric normotensive insulin-dependent diabetic patients show greater mean pressure value and pressure load during ambulatory blood pressure monitoring, and these variables correlate with urinary excretion of albumin.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Venturi scrubbers are high efficiency gas cleaners in which suspended particles are removed from gas streams by droplets formed by liquid atomisation, usually in the venturi throat. The size of the droplets formed is of fundamental importance to the performance of the equipment, both in terms of pressure drop and collection efficiency. In this study, drop sizes in a cylindrical laboratory scale venturi scrubber were measured using a laser diffraction technique. Gas velocity and liquid to gas ratios varied from 50 to 90 m/s and 0.5 to 2.0 l/m3, respectively. Water was inserted as perpendicular jets at the beginning of the throat. Measurements were performed at three positions: two located along the throat, and the last one at the end of the diffuser. The data presented here are a typical example of pneumatic atomisation and can be relevant to other industrial applications such as combustion and engine technology. Finally, results are compared to available correlations and the validity of these equations is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High-temperature liquid chromatography (HTLC) is a technique that presents a series of advantages in liquid phase separations, such as: reduced analysis time, reduced pressure drop, reduced asymmetry factors, modified retentions, controlled selectivities, better efficiencies and improved detectivities, as well as permitting green chromatography. The practical limitations that relate to instrumentation and to stationary phase instability are being resolved and this technique is now ready to be applied for routine determinations.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this study a hydrocyclone filter of 20 cm was selected and its performance was evaluated by studying the variation of discharge, pressure drop, influent concentration, and filtration efficiency with elapsed time of operation. The filter was tested with clean water to determine clean pressure drop and later it was tested with four concentrations of solid suspension, viz. 300; 600; 900 and 1,200 mg L-1. In the concentration of 300 mg L-1, the variation of pressure drop was low. But for the other concentrations of solid suspension, the variation was significant. The maximum pressure drops obtained were 41.19, 45.11, 50.01 and 52.95 kPa at 350, 390, 280 and 190 minutes of elapsed time, respectively. The maximum efficiency of solid suspension was 30.3, 32.96, 43.89 and 52.5% where as the minimum efficiencies were 9.91, 9.93, 9.62 and 9.9%, respectively. The hydrociclone tested presented inefficiency to filter small particles as clay. The initial removal efficiency of higher concentration was bigger than for lower concentration but, the final efficiency are almost the same irrespective of the concentration of solid suspension. The present tested hydrocyclone could be used as a pre-filter microirrigation to prevent emitter clogging.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The knowledge of the slug flow characteristics is very important when designing pipelines and process equipment. When the intermittences typical in slug flow occurs, the fluctuations of the flow variables bring additional concern to the designer. Focusing on this subject the present work discloses the experimental data on slug flow characteristics occurring in a large-size, large-scale facility. The results were compared with data provided by mechanistic slug flow models in order to verify their reliability when modelling actual flow conditions. Experiments were done with natural gas and oil or water as the liquid phase. To compute the frequency and velocity of the slug cell and to calculate the length of the elongated bubble and liquid slug one used two pressure transducers measuring the pressure drop across the pipe diameter at different axial locations. A third pressure transducer measured the pressure drop between two axial location 200 m apart. The experimental data were compared with results of Camargo's1 algorithm (1991, 1993), which uses the basics of Dukler & Hubbard's (1975) slug flow model, and those calculated by the transient two-phase flow simulator OLGA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The flow of Bingham liquids through porous media has been studied. Experiments have been performed to determine the flow rate / pressure drop relationship for the flow of a grease of Binghamian rheological behavior through an array of rods of circular cross section. The yield stress and plastic viscosity of the grease have been determined with the aid of a controlled stress rotational rheometer. To investigate a wider range of the flow parameters, the mass and momentum conservation equations have been solved numerically, in conjunction with the generalized Newtonian constitutive law and the bi-viscosity model. The finite volume method has been employed to obtain the numerical solution. These numerical results also yielded a flow rate / pressure drop relationship, which is in very good agreement with the experimental results. A capillaric theory has been developed to determine an analytical relationship between the flow rate and pressure drop for flows of Bingham liquids through porous media. It is shown that the predictions of this theory are in good agreement with the experimental and numerical results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the influence of the quality of sleep on the nocturnal physiological drop in blood pressure during ambulatory blood pressure monitoring. METHODS: We consecutively assessed ambulatory blood pressure monitoring, the degree of tolerance for the examination, and the quality of sleep in 168 patients with hypertension or with the suspected "white-coat" effect. Blood pressure fall during sleep associated with a specific questionnaire and an analogical visual scale of tolerance for ambulatory blood pressure monitoring were used to assess usual sleep and sleep on the day of examination. Two specialists in sleep disturbances classified the patients into 2 groups: those with normal sleep and those with abnormal sleep. RESULTS: Fifty-nine (35 %) patients comprised the abnormal sleep group. Findings regarding the quality of sleep on the day of ambulatory blood pressure monitoring as compared with those regarding the quality of sleep on a usual day were different and were as follows, respectively: total duration of sleep (-12.4±4.7 versus -42.2±14.9 minutes, P=0.02), latency of sleep (0.4±2.7 versus 17±5.1 minutes, P<0.001), number of awakenings (0.1±0.1 versus 1.35±0.3 times, P<0.001), and tolerance for ambulatory blood pressure monitoring (8±0.2 versus 6.7±0.35, P=0.035). An abnormal drop in blood pressure during sleep occurred in 20 (18%) patients in the normal sleep group and in 14 (24%) patients in the abnormal sleep group, P=0.53. CONCLUSION: Ambulatory blood pressure monitoring causes sleep disturbances in some patients, and a positive association between quality of sleep and tolerance for the examination was observed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Blood pressure pattern was analyzed in 12 complete quadriplegics with chronic lesions after three months of treadmill gait training. Before training, blood pressure values were obtained at rest, during treadmill walking and during the recovery phase. Gait training was performed for 20 min twice a week for three months. Treadmill gait was achieved using neuromuscular electrical stimulation, assisted by partial body weight relief (30-50%). After training, blood pressure was evaluated at rest, during gait and during recovery phase. Before and after training, mean systolic blood pressures and heart rates increased significantly during gait compared to rest (94.16 ± 5.15 to 105 ± 5.22 mmHg and 74.27 ± 10.09 to 106.23 ± 17.31 bpm, respectively), and blood pressure decreased significantly in the recovery phase (86.66 ± 9.84 and 57.5 ± 8.66 mmHg, respectively). After three months of training, systolic blood pressure became higher at rest (94.16 ± 5.15 mmHg before training and 100 ± 8.52 mmHg after training; P < 0.05) and during gait exercise (105 ± 5.22 mmHg before and 110 ± 7.38 mmHg after training; P < 0.05) when compared to the initial values, with no changes in heart rate. No changes occurred in blood pressure during the recovery phase, with the lower values being maintained. A drop in systolic pressure from 105 ± 5.22 to 86.66 ± 9.84 mmHg before training and from 110 ± 7.38 to 90 ± 7.38 mmHg after training was noticed immediately after exercise, thus resulting in hypotensive symptoms when chronic quadriplegics reach the sitting position from the upright position.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

^len^lpt^aOBJETIVO: Descrever a prevalência de pressão arterial limítrofe (PAL) e hipertensão (HT) entre adultos jovens e avaliar a associação entre tamanho ao nascer e PAL/HT. MÉTODOS: Dados foram coletados do primeiro estudo brasileiro de coorte de nascimentos em Ribeirão Preto (sudeste do Brasil), iniciado em 1978/79. De 6.827 recém-nascidos de parto único hospitalar, 2.060 foram avaliados aos 23/25 anos. Foram realizadas coleta de sangue, avaliação antropométrica e obtidas informações sobre ocupação, escolaridade, hábitos de vida e doenças crônicas. Pressão arterial (PA) foi classificada em: 1) PAL: PA sistólica (PAS) ≥ 130 e < 140 mm Hg e/ou PA diastólica (PAD) ≥ 85 e < 90 mmHg; 2) HT: PAS ≥ 140 e/ou PAD ≥ 90 mm Hg. Foi aplicado modelo de regressão logística politômica. RESULTADOS: A prevalência de PAL foi de 13,5% (homens 23,2%) e a de HT, 9,5% (homens 17,7%). PAL foi independentemente associada com sexo masculino (RR 8,84; IC95%: 6,09;12,82), comprimento ao nascer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de massa corporal (IMC) ≥ 30 kg/m² (RR 3,23; 2,02; 5,15) e circunferência de cintura alterada (RR 1,61; 1,13;2,29), enquanto HT associou-se com sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m² (RR 3,68; 2,23;6,06), circunferência de cintura alterada (RR 2,68; 1,77;4,05) e glicemia elevada (RR 2,55; 1,27;5,10), mas não com comprimento ao nascer. CONCLUSÕES: As prevalências de PAL e HT entre os adultos jovens dessa coorte foram maiores em homens que em mulheres. Maior comprimento ao nascer foi associado com PAL, mas não com HT, enquanto peso ao nascer não foi associado com PAL ou HT. Fatores de risco do adulto explicaram a maioria dos aumentos de PAL ou HT.^les^aOBJETIVO: Describir la prevalencia de presión arterial limítrofe (PAL) e hipertensión (HT) entre adultos jóvenes y evaluar la asociación entre tamaño al nacer y PAL/HT. MÉTODOS: : Los datos fueron colectados en el primer estudio de cohorte de nacimientos brasileño en Ribeirao Preto (sureste de Brasil), iniciado en 1978/79. De 6.827 recién nacidos de parto único hospitalario, 2.060 fueron evaluados a los 23/25 años. Se realizaron colecta de sangre, evaluación antropométrica y obtenidas informaciones sobre ocupación, escolaridad, hábitos de vida y enfermedades crónicas. Presión arterial (PA) fue clasificada en: 1) PAL: PA sistólica (PAS) ≥ 130 y < 140 mm Hg y/o PA diastólica (PAD) ≥ 85 y < 90 mm Hg; 2) HT: PAS ≥ 140 y/o PAD ≥ 90 mm Hg. Se aplicó modelo de regresión logística politómica. RESULTADOS: La prevalencia de PAL fue de 13,5% (hombres 23,2%) y la de HT, 9,5% (hombres 17,7%). PAL fue independientemente asociada con sexo masculino (Riesgo Relativo - RR) 8,84; 95%IC: 6,09;12,82), estatura al nacer ≥ 50 cm (RR 1,97; 1,04; 3,73), índice de masa corporal (IMC) ≥ 30 kg/m2 (RR 3,23; 2,02; 5,15) y circunferencia de cintura alterada (RR 1,61; 1,13;2,29), mientras el HT se asoció con sexo masculino (RR 15,18; 8,92;25,81), IMC ≥ 30 kg/m2 (RR 3,68; 2,23;6,06), circunferencia de cintura alterada (RR 2,68; 1,77;4,05) y glicemia elevada (RR 2,55; 1,27;5,10), pero no con estatura al nacer. CONCLUSIONES: Las prevalencias de PAL y HT entre los adultos jóvenes de la cohorte fueron mayores en hombres que en mujeres. Mayor estatura al nacer fue asociado con PAL, pero no con HT, mientras que el peso al nacer no estuvo asociado con PAL o HT. Factores de riesgo de adulto explicaron la mayoría de los aumentos de PAL o HT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Previous studies describe an imbalance of the autonomic nervous system in Chagas' disease causing increased sympathetic activity, which could influence the genesis of hypertension. However, patients undergoing regular physical exercise could counteract this condition, considering that exercise causes physiological responses through autonomic and hemodynamic changes that positively affect the cardiovascular system. This study aimed to evaluate the effects of an exercise program on blood pressure in hypertensive patients with chronic Chagas' heart disease. METHODS: We recruited 17 patients to a 24-week regular exercise program and used ambulatory blood pressure monitoring before and after training. We determined the differences in the systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean blood pressure (MBP) from the beginning to the end of the study. RESULTS: The blood pressures were evaluated in general and during periods of wakefulness and sleep, respectively: SBP (p = 0.34; 0.23; 0.85), DBP (p = 0.46; 0.44; 0.94) and MBP (p = 0.41; 0.30; 0.97). CONCLUSIONS: There was no statistically significant change in blood pressure after the 24-week exercise program; however, we concluded that physical training is safe for patients with chronic Chagas' disease, with no incidence of increase in blood pressure.