95 resultados para occult blood test

em Scielo Saúde Pública - SP


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The studied family showed the presence of four different types of hemoglobin. The family member who gave rise to this study (=propositus) presented Hb C and the hybrid Hb CG-phila. The propositus has three children, all of which have Hb AC; none of the family members showed any clinical symptoms. The investigation of the hemoglobin arose from the finding of target red cells in a blood test done during the pre-operatory examination for lower limb varicose vein stripping. The hybrid Hb CG-phila is due to two gene pairs, each of which with individual expression, determining the synthesis and the particular type subunits. The hybrid Hb CG-phila is formed by the combination velocity of the subunits alpha2G-philabeta2; therefore the proportion of the hybrid Hb CG-phila is lower than Hb G-phila and Hb C. The identification and molecular characterization of Hb G-phila showed the position alpha268 Asn->Lys beta2 and Hb C showed alpha2beta26 Glu->Lys.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A total of 207 patients with malaria caused by Plasmodium falciparum were submitted to 5 different treatment schedules with clindamycin from 1981 to 1984: A - 89 patients were treated intravenously and orally, or intramuscularly and orally with 20 mg/kg/day divided into two daily applications for 5 to 7 days; B-40 patients were treated orally with 20 mg/kg/day divided into two daily doses for 5 to 7 days; C-27 patients were treated with 20 mg/kg/day intravenously or orally divided into two daily applications for 3 days; D-16 patients were treated orally and/or intravenously with a single daily dose of 20 to 40 mg/kg/day for 5 to 7 days; E-35 patients were treated orally with 5 mg/kg/day divided into two doses for 5 days. Patients were examined daily during treatment and reexamined on the 7th, 24th, 21st, 28th and 35th day both clinically and parasitologically (blood test). Eighty three (40.1%) had moderate or severe malaria, and 97 (46.8%) had shown resistance to chloroquine or to the combination ofsulfadoxin and pyrimethamine. The proportion of cured patients was higher than 95% among patients submitted to schedules A and B. Side effects were only occasional and of low intensity. Three deaths occurred (1.4%), two of them involving patients whose signs and symptoms were already very severe when treatment was started. Thus, clindamycin proved to be very useful in the treatment of patients with malaria caused by Plasmodium falciparum and we recommend schedule A for moderate and severe cases and Bfor initial cases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Colorectal cancer (CRC) is the third most common cancer in the world, and mortality has remained the same for the past 50 years, despite advances in diagnosis and treatment. Because significant numbers of patients present with advanced or incurable stages, patients with pre-malignant lesions (adenomatous polyps) that occur as result of genetic inheritance or age should be screened, and patients with long-standing inflammatory bowel disease should undergo surveillance. There are different risk groups for CRC, as well as different screening strategies. It remains to be determined which screening protocol is the most cost-effective for each risk catagory. The objective of screening is to reduce morbidity and mortality in a target population. The purpose of this review is to analyze the results of the published CRC screening studies, with regard to the measured reduction of morbidity and mortality, due to CRC in the studied populations, following various screening procedures. The main screening techniques, used in combination or alone, include fecal occult blood tests, flexible sigmoidoscopy, and colonoscopy. Evidence from the published literature on screening methods for specific risk groups is scanty and frequently does not arise from controlled studies. Nevertheless, data from these studies, combined with recent advances in molecular genetics, certainly lead the way to greater efficacy and lower cost of CRC screening.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Anti-HBc positivity is a frequent cause of donation rejection at blood banks. Hepatitis B virus (HBV) infection may also occur in HBsAg-negative patients, a situation denoted occult infection. Similarly, very low levels of HBV-DNA have also been found in the sera of patients with chronic hepatitis C virus (HCV) infection, even in the absence of serum HBsAg. Initially we searched for HBV-DNA in serum of 100 blood donors and 50 HCV-infected patients who were HBsAg negative/anti-HBc positive by nested-PCR and by an HBV monitor commercial test for HBV-DNA. Anti-HBs seroconversion rates were measured in 100 blood donors and in 22 patients with chronic HCV infection after HBV vaccination to determine if the HBV vaccination could eliminate an occult HBV infection in these individuals. Occult HBV infection was detected in proportionally fewer blood donors (6/100 = 6%) than chronic hepatitis C patients (12/50 = 24%) (P < 0.05). We noted seroconversion in 6/6 (100%) HBV-DNA(+) and in 84/94 (89.4%) HBV-DNA(-) blood donors (P > 0.05). All subjects who were HBV-DNA(+) before the first dose of HBV vaccine (D1), became HBV-DNA(-) after D1, D2, and D3. Among 22 HCV-positive patients, 10 HBV-DNA(+) and 12 HBV-DNA(-), seroconversion was observed in 9/10 (90%) HBV-DNA(+) and in 9/12 (75%) HBV-DNA(-) subjects (P > 0.05). The disappearance of HBV-DNA in the majority of vaccinated patients suggests that residual HBV can be eliminated in patients with occult infection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION: HTLV-1/2 screening among blood donors commonly utilizes an enzyme-linked immunosorbent assay (EIA), followed by a confirmatory method such as Western blot (WB) if the EIA is positive. However, this algorithm yields a high rate of inconclusive results, and is expensive. METHODS: Two qualitative real-time PCR assays were developed to detect HTLV-1 and 2, and a total of 318 samples were tested (152 blood donors, 108 asymptomatic carriers, 26 HAM/TSP patients and 30 seronegative individuals). RESULTS: The sensitivity and specificity of PCR in comparison with WB results were 99.4% and 98.5%, respectively. PCR tests were more efficient for identifying the virus type, detecting HTLV-2 infection and defining inconclusive cases. CONCLUSIONS: Because real-time PCR is sensitive and practical and costs much less than WB, this technique can be used as a confirmatory test for HTLV in blood banks, as a replacement for WB.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The course of human Leishmania chagasi infections appears to be determined by the balance between type 1 (T1) CD4+ and CD8+ T suppressor (Ts) cell activities. Skin test positive adults living in hyperendemic areas who have no history of visceral leishmaniasis (VL) have T1 CD4+ T cell immunodominant responses against L. chagasi. The cytokines they secrete during anti-leishmania responses are a probable source of cytokines which inhibit the CD8+ Ts cells associated with VL. The ability of supernatants generated from peripheral blood mononuclear cells derived from skin test positive adults to reverse immune responses which appear to be mediated by CD8+ Ts cells was assessed in three sets of screening assays. The supernatants displayed three candidate factors. One, which could be explained by Leishmania antigens in the supernatant, decreased high endogenous IL-10 secretion characteristic of one class of VL patients. A second activity decreased high endogenous proliferation characteristic of the same class of patients without decreasing antigen specific proliferation. The third activity inhibited or killed CD8+ T cells but not CD4+ T cells. These activities might be useful in treating VL.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Exaggerated blood pressure response (EBPR) during the exercise treadmill test (ETT) has been considered to be a risk factor for hypertension. The relationship of polymorphisms of the renin-angiotensin system gene with hypertension has not been established. Our objective was to evaluate whether EBPR during exercise is a clinical marker for hypertension. The study concerned a historical cohort of normotensive individuals. The exposed individuals were those who presented EBPR. At the end of the observation period (41.7 months = 3.5 years), the development of hypertension was analyzed within the two groups. Genetic polymorphisms and blood pressure behavior were assessed as independent variables, together with the classical risk factors for hypertension. The I/D gene polymorphism of the angiotensin-converting enzyme and M235T of angiotensinogen were ruled out as risk factors for hypertension. EBPR during ETT is not an independent influence on the chances of developing hypertension. No differences were observed between the hypertensive and normotensive individuals regarding gender (P = 0.655), skin color (P = 0.636), family history of hypertension (P = 0.225), diabetes mellitus (P = 0.285), or hypertriglyceridemia (P = 0.734). The risk of developing hypertension increased with increasing body mass index (BMI) and advancing age. The risk factors, which independently influenced the development of hypertension, were age and BMI. EBPR did not constitute an independent risk factor for hypertension and is probably a preclinical phase in the spectrum of normotension and hypertension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/PvTM test for vivax malaria diagnosis in Belém, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25°C, 30°C, and 37°C) for 24 hours before use. Overall sensitivity of ICT Pf/PvTM was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The prevalence and clinical forms of Trypanosoma cruzi were evaluated among blood donor candidates attended at a general hospital in Rio de Janeiro, Brazil, from January 1997 to April 1999. The investigation was done by means of the indirect hemagglutination test and was confirmed via ELISA. Data were collected from clinical examinations, conventional electrocardiogram, chest radiography and echocar-diography. The results showed that despite Trypanosoma cruzi prevalence of 1.17% (128 patients), mainly in males aged 40 years or over, 70.8% of these patients, mainly males aged 19 to 39 years, demonstrated abnormalities that allowed the diagnosis of cardiopathy and/or esophagopathy. This once again corroborates the importance of Trypanosoma cruzi infection in urban centers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Between October 1988 and April 1989 a cross-sectional survey was carried out in six out of eight blood banks of Goiânia, Central Brazil. Subjects attending for first-time blood donation in the mornings of the study period (n = 1358) were interviewed and screened for T. cruzi infection as a part of a major study among blood donors. Tests to anti-T. cruzi antibodies were performed, simultaneously, by indirect hem agglutination test (IHA) and complement fixation test (CFT). A subject was considered seropositive when any one of the two tests showed a positive result. Information on age, sex, place of birth, migration and socio-economic level was recorded. Results from this survey were compared with seroprevalence rates obtained in previous studies in an attempt to analyse trend of T. cruzi infection in an endemic urban area. The overall seroprevalence of T. cruzi infection among first-time donors was found to be 3.5% (95% confidence interval 2.5%-4.5% ). The seroprevalence rate increased with age up to 45 years and then decreased. Migrants from rural areas had higher seroprevalence rates than subjects from urban counties (1.8%-16.2% vs. 0%-3.6%). A four fold decrease in prevalence rates was observed when these rates were compared with those of fifteen years ago. Two possible hypotheses to explain this difference were suggested: 1. a cohort effect related with the decrease of transmission in rural areas and/or 2. a differential proportion of people of rural origin among blood donors between the two periods. The potential usefulness of blood banks as a source of epidemiological information to monitor trends of T. cruzi infection in an urban adult population was stressed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A laboratory study was conducted to test the toxicity of synthetic insecticides added to defibrinated sheep blood kept at room temperature and offered as food to the following triatomine species: Triatoma infestans, Panstrongylus megistus, Triatoma vitticeps, Triatoma pseudomaculata, Triatoma brasiliensis and Rhodnius prolixus. The insecticides used, at a concentration of 1g/l, were: HCH, DDT, Malathion and Trichlorfon, and the lethalithy observed at the end of a 7-day period varied according to the active principle of each. HCH was the most effective by the oral route, killing 100% of the insects, except P. megistus (95.7%) and T. pseudomaculata (94.1%). Trichlorfon killed the insects at rates ranging from 71.8% (T. vitticeps) to 98% (R. prolixus). Malathion was slightly less efficient, killing the insects at rates from 56.8% (T. vitticeps) to 97% (T.brasiliensis). DDT was the least effective, with a killing rate of 10% (T. vitticeps) to 75% (T.brasiliensis). Since the tests were performed at room temperature, we suggest that baits of this type should be tried for the control of triatomines in the field.