7 resultados para objective quality assessment

em Scielo Saúde Pública - SP


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION : In 2011, the Brazilian Ministry of Health rolled out a program for the external quality assessment of rapid human immunodeficiency virus (HIV) tests using the dried tube specimen (DTS) method (EQA-RT/DTS-HIV). Our objective was to evaluate the implementation of this program at 71 voluntary counseling and testing centers (VCTCs) in the Brazilian Legal Amazonian area one year after its introduction. METHODS : Quantitative and qualitative study that analyzed secondary data and interviews with healthcare workers (HCWs) (n=39) and VCTC coordinators (n=32) were performed. The assessment used 18 key indicators to evaluate the three dimensions of the program's logical framework: structure, process, and result. Each indicator was scored from 1-4, and the aggregate results corresponding to the dimensions were expressed as proportions. The results were compared to the perceptions of the HCWs and coordinators regarding the EQA-RT/DTS-HIV program. RESULTS: The aggregate scores for the three dimensions of structure, process, and result were 91.7%, 78.6%, and 95%, respectively. The lowest score in each dimension corresponded to a different indicator: access to Quali-TR online system 39% (structure), registration in Quali-TR online system 38.7% (process), and VCTC completed the full process in the program's first round 63.4% (result). Approximately 36% of the HCWs and 52% of the coordinators reported enhanced trust in the program for its rapid HIV testing performance. CONCLUSIONS: All three program dimensions exhibited satisfactory results (>75%). Nevertheless, the study findings highlight the need to improve certain program components. Additionally, long-term follow-ups is needed to provide a more thorough picture of the process for external quality assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: The development of clinical practice guidelines (CPGs) has increased; this study aimed to assess the quality of CPGs for the management of Chagas disease. METHODS: Following a systematic search of the scientific literature, two reviewers assessed the eligible guidelines using the Appraisal of Guidelines Research and Evaluation (AGREE) II instrument. RESULTS: Five CPGs were included. The AGREE domains of scope/purpose, stakeholder involvement, and clarity of presentation were rated well, and the domains of applicability and editorial independence received poor ratings. CONCLUSIONS: The quality of CPGs for Chagas disease is poor, and significant work is required to develop high-quality guidelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interpretation of oligonucleotide array experiments depends on the quality of the target cRNA used. cRNA target quality is assessed by quantitative analysis of the representation of 5' and 3' sequences of control genes using commercially available Test arrays. The Test array provides an economically priced means of determining the quality of labeled target prior to analysis on whole genome expression arrays. This manuscript validates the use of a duplex RT-PCR assay as a faster (6 h) and less expensive (quality. Forty-one different cRNA samples were hybridized to HG-U133A microarrays from Affymetrix. Ten cRNA samples with a ß-actin 3'/5' ratio >6 were chosen and classified as degraded cRNAs, and 31 samples with a ß-actin 3'/5' ratio <6 were selected as good quality cRNAs. Blinded samples were then used for the RT-PCR assay. After gel electrophoresis, optical densities of the amplified 3' and 5' fragments of ß-actin were measured and the 3'/5' ratio was calculated. There was a strong correlation (r² = 0.6802) between the array and the RT-PCR ß-actin 3'/5' ratios. Moreover, the RT-PCR 3'/5' ratio was significantly different (P < 0.0001) between undegraded (mean ± SD, 0.34 ± 0.09) and degraded (1.71 ± 0.83) samples. None of the other parameters analyzed, such as i) the starting amount of RNA, ii) RNA quality assessed using the Bioanalyzer Chip technology, or iii) the concentration and OD260/OD280 ratio of the purified biotinylated cRNA, correlated with cRNA quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cellular structure of healthy food products, with added dietary fiber and low in calories, is an important factor that contributes to the assessment of quality, which can be quantified by image analysis of visual texture. This study seeks to compare image analysis techniques (binarization using Otsu’s method and the default ImageJ algorithm, a variation of the iterative intermeans method) for quantification of differences in the crumb structure of breads made with different percentages of whole-wheat flour and fat replacer, and discuss the behavior of the parameters number of cells, mean cell area, cell density, and circularity using response surface methodology. Comparative analysis of the results achieved with the Otsu and default ImageJ algorithms showed a significant difference between the studied parameters. The Otsu method demonstrated the crumb structure of the analyzed breads more reliably than the default ImageJ algorithm, and is thus the most suitable in terms of structural representation of the crumb texture.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To investigate the relevance of subjective criteria adopted by a psychiatry and psychology consultation-liaison service, and their suitability in the evaluation of case registries and objective results. METHODS: Semi-structured interviews were conducted and all supervisors of the university hospital service were interviewed. Routinely collected case registries were also reviewed. Standardized assessment with content analysis for each category was carried out. RESULTS: The results showed distortions in the adopted service focus (doctor-patient relationship) and consultant requests. This focus is more on consulting physician-oriented interventions than on patients. DISCUSSION: Evaluation of the relevance of service criteria could help promoting quality assessment of the services provided, mainly when objective criteria have not yet been established to assure their suitability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Groundwater from nine wells of three different districts, located at Sana'a secretariat was analyzed for hydrochemical quality assessment. Measurements of water quality parameters including pH, EC, CO3(2-), HCO3-, Cl-, NO3-, SO4(2-), Ca2+, Mg2+, Fe3+, K+, and Na+ were carried out . Classification of the groundwater samples according to Cl, SO4(2-), CO3(2-) and HCO3-, hardness (H), total dissolved solids (TDS), base-exchange, and meteoric genesis was demonstrated. Suitability of ground water samples for irrigation and industrial uses according to sodium adsorption ration (SAR), ratio of dissolved sodium (RDS), residual sodium carbonate (RSC) and saturation index (SI) was also investigated. The results of this study showed that almost all ground water samples were of good quality that makes them suitable for drinking and domestic uses. Results also indicated that even though some of the ground water samples were suitable for irrigation purposes, almost all of them were found not be good for industrial uses. Despite all drawbacks of the sewerage system built around Sana'a secretariat at the beginning of the first decade of the third millennium, the results of this study indicate that there is scope of significant improvement in Sana'a secretariat ground water quality.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: The assessment of an easy to prepare and low cost control material for Hematology, available for manual and automated methods. MATERIAL AND METHOD: Aliquots of stabilized whole blood were prepared by partial fixation with aldehydes; the stability at different temperatures (4. 20 and 37 °C) during periods of up to 8-9 weeks and aliquot variability with both methods were controlled. RESULTS: Aliquot variability with automated methods at day 1, expressed as CV% (coefficient of variation) was: white blood cells (WBC) 2.7, red blood cells (RBC) 0.7, hemoglobin (Hb) 0.6, hematocrit (Hct) 0.7, mean cell volume (MCV) 0.3, mean cell hemoglobin (MCH) 0.6, mean cell hemoglobin concentration (MCHC) 0.7, and platelets (PLT) 4.6. The CV (coefficient of variation) percentages obtained with manual methods in one of the batches were: WBC 23, Hct 2.8, Hb 4.5, MCHC 5.9, PLT 41. Samples stored at 4ºC and 20ºC showed good stability, only a very low initial hemolysis being observed, whereas those stored at 37ºC deteriobed a rapidly (metahemoglobin formation, aggregation of WBC and platelets, as well as alteration of erythrocyte indexes). CONCLUSIONS: It was confirmed that, as long as there is no exposure to high temperatures during distribution, this material is stable, allowing assessment, both esternal and internal, for control purposes, with acceptable reproductivity, both for manual and auttomatic methods.