105 resultados para neutrality statistical test

em Scielo Saúde Pública - SP


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective: Presenting a Virtual Environment (VE) based on the Protocol of Treatment of Hypertension and Diabetes Mellitus type 2, used in Primary Care for evaluation of dietary habits in nursing consultations. Method: An experimental study applied by two nurses and a nurse manager, in a sample of 30 deaf patients aged between 30 and 60 years. The environment was built in Visual Basic NET and offered eight screens about feeding containing food pictures, videos in Libras (Brazilian sign language) and audio. The analysis of the VE was done through questionnaires applied to patients and professionals by the Poisson statistical test. Results: The VE shows the possible diagnostics in red, yellow, green and blue colors, depending on the degree of patients’ need. Conclusion: The environment obtained excellent acceptance by patients and nurses, allowing great interaction between them, even without an interpreter. The time in consultation was reduced to 15 minutes, with the preservation of patient privacy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work shows the results of a Proficiency Testing performed by a partnership between INMETRO and ANP. The performance of 49 Brazilian laboratories (using the z-score statistical test) in determining 10 quality parameters of ethanol fuel and biodiesel was evaluated. The certified reference values were provided by INMETRO, allowing a more rigorous assessment of the laboratories. For hydrous ethanol, the acidity parameter showed the lowest number of laboratories with satisfactory results (48%), while 85% of the laboratories presented satisfactory results for ethanol content. For biodiesel, the percentage of laboratories with satisfactory results ranged from 46% (kinematic viscosity) to 92% (acid number).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A survey for canine tegumentary leishmaniasis (CTL) has been carried out between 1986 and 1993 in seven endemic localities for American cutaneous leishmaniasis in the State of Rio de Janeiro. 270 dogs have been examined for their clinical aspects, the development of delayed hypersensitivity (DHS) with Immunoleish antigen and with immunofluorescent antibody research of IgG (IF). 28.2% of them had ulcer lesions and 3.3% had scars. The lesions consisted of single (39.5%) and mucocutaneous lesions (31.6%), multiple cutaneous (25.0%) and mucocutaneous lesions associated with cutaneous ulcers (4.0%). Twelve (15.8%) isolates from biopsies were analyzed by zimodeme and schizodeme and identified as L. (V.) braziliensis. The overall prevalence of canine infection that was evaluated with the skin test was of 40.5% and with IF it was of 25.5%. Both tests showed a high positive rate with relation to the animals with mucosal lesions, as in the case of human mucocutaneous leishmaniasis. The comparison of the two tests showed the skin test to have a better performance although there was no statistical difference (p>0.05) between them. The proportional sensitivity and specificity was of 84.0% and 74.0%, respectively. The Immunoleish skin test and IF are useful tools to be employed in CTL field epidemiological surveys.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Antibody in human sera that induces lysis of sheep erythrocytes in hemolytic assay was investigated. The present study showed that the presence in serum of the thermostable cytolytic anti-sheep red blood cells antibodies is dependent on the Schistosoma mansoni infection, and this is more frequent in adults than in children. The thermostable characteristic of hemolysins in normal sera was not dependent on the presence of Ascaris lumbricoides, Trichuris trichiura or hookworm geo-helminths. Further, thermostable complement-activating heterophile antibodies were noticed in children in association with massive number of S. mansoni eggs. The results were obtained by using the z- and the chi-square tests. The z-test allows us to formulate a one-sided alternative, i.e., a tendency of one of the attributes. On the other hand, the chi-square test analyzes the independence between attributes by using a contingency table. Besides the obtained results being interesting in the field of schistosomiasis mansoni, they can provide a new insight into the use of statistics in medical science.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study intended to analyze the seroprevalence of Helicobacter pylori, IgG, and its relation to dyspepsia in a population from the western Amazon region. During the "Projeto Bandeira Científica", a University of São Paulo Medical School program, in Monte Negro's rural areas, state of Rondônia, 266 blood samples were collected from volunteers. The material was tested for IgG antibodies anti-Helicobacter pylori by ELISA method and the participants were also interviewed on dyspepsia, hygiene and social aspects. Participants aged between five and 81 years old (34 years on average), 149 (56%) were female and 117 (44%) male. We found 210 (78.9%) positive, 50 (18.8%) negative and six (2.3%) undetermined samples. Dyspeptic complaints were found in 226 cases (85.2%). There was no statistical association between dyspepsia and positive serology for H. pylori. We concluded that the seroprevalence in all age categories is similar to results found in other studies conducted in developing countries, including those from Brazil. On the other hand, the seroprevalence found in Monte Negro was higher than that reported in developed countries. As expected, there was a progressive increase in the positivity for H. pylori in older age groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background: The kinetics of high-sensitivity troponin T (hscTnT) release should be studied in different situations, including functional tests with transient ischemic abnormalities. Objective: To evaluate the release of hscTnT by serial measurements after exercise testing (ET), and to correlate hscTnT elevations with abnormalities suggestive of ischemia. Methods: Patients with acute ST-segment elevation myocardial infarction (STEMI) undergoing primary angioplasty were referred for ET 3 months after infarction. Blood samples were collected to measure basal hscTnT immediately before (TnT0h), 2 (TnT2h), 5 (TnT5h), and 8 hours (TnT8h) after ET. The outcomes were peak hscTnT, TnT5h/TnT0h ratio, and the area under the blood concentration-time curve (AUC) for hscTnT levels. Log-transformation was performed on hscTnT values, and comparisons were assessed with the geometric mean ratio, along with their 95% confidence intervals. Statistical significance was assessed by analysis of covariance with no adjustment, and then, adjusted for TnT0h, age and sex, followed by additional variables (metabolic equivalents, maximum heart rate achieved, anterior wall STEMI, and creatinine clearance). Results: This study included 95 patients. The highest geometric means were observed at 5 hours (TnT5h). After adjustments, peak hscTnT, TnT5h/TnT0h and AUC were 59% (p = 0.002), 59% (p = 0.003) and 45% (p = 0.003) higher, respectively, in patients with an abnormal ET as compared to those with normal tests. Conclusion: Higher elevations of hscTnT may occur after an abnormal ET as compared to a normal ET in patients with STEMI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the efficiency of spatial statistical analysis in the selection of genotypes in a plant breeding program and, particularly, to demonstrate the benefits of the approach when experimental observations are not spatially independent. The basic material of this study was a yield trial of soybean lines, with five check varieties (of fixed effect) and 110 test lines (of random effects), in an augmented block design. The spatial analysis used a random field linear model (RFML), with a covariance function estimated from the residuals of the analysis considering independent errors. Results showed a residual autocorrelation of significant magnitude and extension (range), which allowed a better discrimination among genotypes (increase of the power of statistical tests, reduction in the standard errors of estimates and predictors, and a greater amplitude of predictor values) when the spatial analysis was applied. Furthermore, the spatial analysis led to a different ranking of the genetic materials, in comparison with the non-spatial analysis, and a selection less influenced by local variation effects was obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two high performance liquid chromatography (HPLC) methods for the quantitative determination of indinavir sulfate were tested, validated and statistically compared. Assays were carried out using as mobile phases mixtures of dibutylammonium phosphate buffer pH 6.5 and acetonitrile (55:45) at 1 mL/min or citrate buffer pH 5 and acetonitrile (60:40) at 1 mL/min, an octylsilane column (RP-8) and a UV spectrophotometric detector at 260 nm. Both methods showed good sensitivity, linearity, precision and accuracy. The statistical analysis using the t-student test for the determination of indinavir sulfate raw material and capsules indicated no statistically significant difference between the two methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 50 mg losartan potassium capsules using HPLC and UV spectrophotometry. A 2(4) full factorial design was carried out to optimize dissolution conditions and potassium phosphate buffer, pH 6.8 as dissolution medium, basket as apparatus at the stirring speed of 50 rpm and time of 30 min were considered adequate. Both dissolution procedure and analytical methods were validated and a statistical analysis showed that there are no significant differences between HPLC and spectrophotometry. Since there is no official monograph, this dissolution test could be applied for quality control routine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work describes the development and validation of a dissolution test for 60 mg of diltiazem hydrochloride in immediate release capsules. The best dissolution in vitro profile was achieved using potassium phosphate buffer at pH 6.8 as the dissolution medium and paddle as the apparatus at 50 rpm. The drug concentrations in the dissolution media were determined by UV spectrophotometry and HPLC and a statistical analysis revealed that there were significant differences between HPLC and spectrophotometry. This study illustrates the importance of an official method for the dissolution test, since there is no official monograph for diltiazem hydrochloride in capsules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An interesting fact about language cognition is that stimulation involving incongruence in the merge operation between verb and complement has often been related to a negative event-related potential (ERP) of augmented amplitude and latency of ca. 400 ms - the N400. Using an automatic ERP latency and amplitude estimator to facilitate the recognition of waves with a low signal-to-noise ratio, the objective of the present study was to study the N400 statistically in 24 volunteers. Stimulation consisted of 80 experimental sentences (40 congruous and 40 incongruous), generated in Brazilian Portuguese, involving two distinct local verb-argument combinations (nominal object and pronominal object series). For each volunteer, the EEG was simultaneously acquired at 20 derivations, topographically localized according to the 10-20 International System. A computerized routine for automatic N400-peak marking (based on the ascendant zero-cross of the first waveform derivative) was applied to the estimated individual ERP waveform for congruous and incongruous sentences in both series for all ERP topographic derivations. Peak-to-peak N400 amplitude was significantly augmented (P < 0.05; one-sided Wilcoxon signed-rank test) due to incongruence in derivations F3, T3, C3, Cz, T5, P3, Pz, and P4 for nominal object series and in P3, Pz and P4 for pronominal object series. The results also indicated high inter-individual variability in ERP waveforms, suggesting that the usual procedure of grand averaging might not be considered a generally adequate approach. Hence, signal processing statistical techniques should be applied in neurolinguistic ERP studies allowing waveform analysis with low signal-to-noise ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The tear film plays an important role in maintaining the integrity of the ocular suface. During general anesthesia, tear production is considerably reduced, which requires care to prevent adverse effects that result in diseases of these structures. Studies comparing the effects of induction of anaesthesia with thiopental and propofol on tear production have not been carried out yet. Because these drugs are used in veterinary medicine, we decided to evaluate the tear production in 30 dogs undergoing experimental surgery as well as routine procedures at the veterinary hospital of Federal University of Viçosa. Patients were divided into two groups of equal number. All animals were sedated with clorpromazine and maintained with isoflurane in diluted oxygen. Group 1 was induced with thiopental whereas group 2 with propofol. Schirmer tear test 1 was performed before sedation (T0), 15 minutes after sedation (T1) and 10 minutes after induction of anesthesia (T2) with the drug chosen for one of the groups. There was a significant decrease in tear production for both drugs, but no significant statistical differences were found between them. Thus, considering the results and the way in which the study was conducted, we suggest protecting the cornea and conjunctiva of patients during anesthesia using any of the drugs here evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate and establish the mean values of IOP in healthy adult sheep using an applanation tonometer. Information on age, sex, and breed was obtained for all animals included in this study. Twenty five healthy sheep (Ovis aries), of the same breed (Texel), male or female, with three years of age, received an ophthalmic examination in both eyes, including pupillary reflexes, Schirmer tear test, slit lamp biomicroscopy, and fluorescein staining. For all ophthalmic testing, animals were gently physically restrained, with no pressure in the jugular area and the eyelids were carefully open. IOP was measured by applanation tonometry (Tonopen XL). The same examiner performed the tonometry; measurements were taken three times for each eye, and their average was recorded as the IOP of the animal. Statistical analysis was performed using paired t-test and values of P < 0.05 were considered significant. The mean intraocular pressure in the whole group of 50 eyes was of 16.36 +/- 2.19 mm Hg. The mean (SD) IOP in the right eye was of 15.96 +/- 2.02 mm Hg, while the mean (SD) IOP in the left eye was of 16.76 +/- 2.32 mm Hg. Significant differences in IOP were not found between right and left eyes. The applanation tonometer was adequate for measuring the intraocular pressure in sheep. Reference data will assist in diagnosing testing for ophthalmic disease in sheep, as¹ well as promote further studies in this area.

Relevância:

20.00% 20.00%

Publicador: