66 resultados para mixed flow
em Scielo Saúde Pública - SP
Resumo:
The focus of this research was to evaluate the horizontal pressures on a cylindrical metal silo of corrugated walls and flat bottom with 1.82m diameter and 5.4m high, and to compare the values with those obtained theoretically by the ISO 11697, EP 433 and AS 3774 standards. The silo was symmetrically filled and constant speed with wheat cv. soft red for two different height/diameter ratios (H/D) and was unloaded through three orifices with a diameter of 71.6mm, one concentric and two eccentrics. Horizontal pressures were measured on the walls of the silo at three positions using hydraulic type pressure cells. The results showed that shortly after the start of the unloading, there was a mass flow above the quota of H/D = 1.2, whereas below this quota funnel flow occurred. It can be said that the EP 433 standard was more appropriate to predict horizontal pressures in silos in H/D ratio = 1.0, with eccentric unloading. For the H/D ratio = 1.5, AS 3774 standard was the one that produced values closer to the experimental.
Resumo:
Mixed convection on the flow past a heated length and past a porous cavity located in a horizontal wall bounding a saturated porous medium is numerically simulated. The cavity is heated from below. The steady-state regime is studied for several intensities of the buoyancy effects due to temperature variations. The influences of Péclet and Rayleigh numbers on the flow pattern and the temperature distributions are examined. Local and global Nusselt numbers are reported for the heated surface. The convective-diffusive fluxes at the volume boundaries are represented using the UNIFAES, Unified Finite Approach Exponential-type Scheme, with the Power-Law approximation to reduce the computing time. The conditions established by Rivas for the quadratic order of accuracy of the central differencing to be maintained in irregular grids are shown to be extensible to other quadratic schemes, including UNIFAES, so that accuracy estimates could be obtained.
Resumo:
The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .
Abnormal expression of CD54 in mixed reactions of mononuclear cells from hyper-IgE syndrome patients
Resumo:
Hyper-IgE syndrome (HIES) is a rare multisystem disorder characterized by increased susceptibility to infections associated with heterogeneous immunologic and non-immunologic abnormalities. Most patients consistently exhibit defective antigen-induced-T cell activation, that could be partly due to altered costimulation involving accessory molecules; however, the expression of these molecules has never been documented in HIES. Therefore, we investigated the expression of CD11a, CD28, CD40, CD54, CD80, CD86, and CD154 in peripheral blood mononuclear cells from six patients and six healthy controls by flow cytometry after autologous and mixed allogeneic reactions. Only the allogeneic stimuli induced significant proliferative responses and interleukin 2 and interferon gamma production in both groups. Most accessory molecules showed similar expression between patients and controls with the exception of CD54, being expressed at lower levels in HIES patients regardless of the type of stimulus used. Decreased expression of CD54 could partly explain the deficient T cell activation to specific recall antigens in HIES patients, and might be responsible for their higher susceptibility to infections with defined types of microorganisms.
Resumo:
An optode based on thymol blue (TB), an acid-based indicator, has been constructed and evaluated as a detector in FIA system for CO2 determination. The dye was chemically immobilised on the surface of a bifurcated glass optical fibre bundle, using silanisation in organic media. In FIA system, hydrogen carbonate or carbonate samples are injected in a buffer carrier solution, and then are mixed with phosphoric acid solution to generate CO2, which diffuses through a PTFE membrane, in order to be collected in an acceptor carrier fluid, pumped towards to detection cell, in which the optode was adapted. The proposed system presents two linear response ranges, from 1.0 x 10-3 to 1.0 x 10-2 mol l-1, and from 2.0 x 10-2 to 0.10 mol l-1. The sampling frequency was 11 sample h-1, with good repeatability (R.S.D < 4 %, n = 10). In flow conditions the optode lifetime was 170 h. The system was applied in the analysis of commercial mineral water and the results obtained in the hydrogen carbonate determination did not differ significantly from those obtained by potentiometry, at a confidence level of 95 %.
Resumo:
Plot-scale overland flow experiments were conducted to evaluate the efficiency of streamside management zones (SMZs) in retaining herbicides in runoff generated from silvicultural activities. Herbicide retention was evaluated for five different slopes (2, 5, 10, 15, and 20%), two cover conditions (undisturbed O horizon and raked surface), and two periods under contrasting soil moisture conditions (summer dry and winter wet season) and correlated to O horizon and site conditions. Picloram (highly soluble in water) and atrazine (moderately sorbed into soil particles) at concentrations in the range of 55 and 35 µg L-1 and kaolin clay (approximately 5 g L-1) were mixed with 13.000 liters of water and dispersed over the top of 5 x 10 m forested plots. Surface flow was collected 2, 4, 6, and 10 m below the disperser to evaluate the changes in concentration as it moved through the O horizon and surface soil horizon-mixing zone. Results showed that, on average, a 10 m long forested SMZ removed around 25% of the initial concentration of atrazine and was generally ineffective in reducing the more soluble picloram. Retention of picloram was only 6% of the applied quantity. Percentages of mass reduction by infiltration were 36% for atrazine and 20% for picloram. Stronger relationships existed between O horizon depth and atrazine retention than in any other measured variable, suggesting that better solid-solution contact associated with flow through deeper O horizons is more important than either velocity or soil moisture as a determinant of sorption.
Resumo:
The effect of molybdenum (Mo) on common bean grown in desiccated corn stover in a no-tillage system was evaluated under two application modes: Mo mixed with the desiccant glyphosate and Mo direct spray to the bean leaves. The treatments (four replicates) were assigned to a completely randomized block design in a split-plot arrangement with the application of Mo (0, 100, 200, 400 and 800 g ha-1) mixed with glyphosate in the main plots and Mo foliar spray (0 and 100 g ha-1) in the sub-plots. The field experiments were carried out in 2009 and 2010 in the municipality of Coimbra, Minas Gerais State, with the common bean cultivar Ouro Vermelho. Mo mixed with glyphosate had neither an effect on common bean yield nor on the Mo and N contents in leaves, however it increased the Mo and N contents in seeds. Application of Mo via foliar spray increased Mo content in leaves and Mo and N contents in seeds. The reapplication of molybdenum with glyphosate for desiccation in subsequent crops caused a cumulative effect of Mo content in bean seeds.
Resumo:
OBJECTIVE To describe the migration flows of demand for public and private hospital care among the health regions of the state of Sao Paulo, Brazil. METHODS Study based on a database of hospitalizations in the public and private systems of the state of Sao Paulo, Southeastern Brazil, in 2006. We analyzed data from 17 health regions of the state, considering people hospitalized in their own health region and those who migrated outwards (emigration) or came from other regions (immigration). The index of migration effectiveness of patients from both systems was estimated. The coverage (hospitalization coefficient) was analyzed in relation to the number of inpatient beds per population and the indexes of migration effectiveness. RESULTS The index of migration effectiveness applied to the hospital care demand flow allowed characterizing health regions with flow balance, with high emigration of public and private patients, and with high attraction of public and private patients. CONCLUSIONS There are differences in hospital care access and opportunities among health regions in the state of Sao Paulo, Brazil.
Resumo:
SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.
Resumo:
We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.
Resumo:
Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.
Resumo:
O ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.
Resumo:
Realizou-se estudo descritivo e exploratório relacionando as covariáveis aos resultados do teste sorológico ML Flow e baciloscopia. Foram estudados 60 casos novos de hanseníase diagnosticados no Centro de Referência em Dermatologia Sanitária. Para a baciloscopia, foi utilizada a coleta de esfregaço dérmico em quatro sítios, sendo o resultado expresso pelo índice bacilocópico. O ML Flow foi registrado de modo qualitativo e semi-quantitativo. Para o estudo da concordância, foi utilizado o índice de Kappa e, para sua interpretação, os critérios de Landis e Koch. Para análise estatística foram realizados a regressão logística e o teste de Kruskal-Wallis. O ML Flow mostrou forte associação com a baciloscopia, observou-se que o aumento gradativo do índice baciloscópico foi acompanhado pelo aumento semi-quantitativo dos níveis de anticorpos medidos pelo ML Flow, tendo sido positivo em 100% dos casos com baciloscopia positiva. Os resultados deste estudo evidenciaram que o ML Flow, por estar fortemente correlacionado à bacilocopia, poderá tornar-se um valioso instrumento auxiliar na classificação e alocação dos pacientes para fins de tratamento.
Resumo:
Estudo descritivo e exploratório correlacionando o ML Flow, a baciloscopia e a classificação em paucibacilar (PB) e multibacilar (MB), envolveu 1.041 casos novos com hanseníase em 13 municípios de Minas Gerais, de outubro de 2002 a março de 2004. A concordância entre o ML Flow e a classificação pelo número de lesões cutâneas e a baciloscopia foi moderada (Kappa:0,51 e 0,48, respectivamente) e, substancial (Kappa:0,77) com a classificação final. De janeiro de 2000 a março de 2004, a proporção de casos novos MB no Estado, passou de 78,1 para 65,8%. A queda no percentual de MB foi maior nos serviços participantes da pesquisa ML Flow (73,1 para 53,3%). A diferença de PB e MB nos serviços participantes e não participantes, de janeiro a março de 2004, foi estatisticamente significativa, indicando implicação direta e benéfica no tratamento e no controle da endemia em Minas Gerais.
Resumo:
O diagnóstico precoce da hanseníase, a correta classificação e o estudo dos fatores de risco relacionados à soropositividade, tornam-se importantes para o tratamento do doente e controle da endemia, especialmente, quando a responsabilidade pelo atendimento desses pacientes está sendo absorvida pelos serviços de atenção básica. Estudo descritivo e exploratório utilizando regressão logística avaliou a associação das variáveis: sexo, idade, modo de detecção, número de lesões cutâneas e de nervos acometidos, grau de incapacidade, baciloscopia, com o resultado do teste sorológico ML Flow, em 1.072 casos novos com hanseníase em 13 municípios de Minas Gerais. A soropositividade (50,7%) estava estatisticamente associada aos pacientes com 15 anos ou mais de idade (OR:2,6), mais de cinco lesões cutâneas (OR:7,5), mais de um nervo acometido (OR:2,4) e com baciloscopia positiva (OR:5,5 para IB<2 e OR:191,2 para IB>2), colaborando, assim, com a classificação e o tratamento adequados dos doentes.