25 resultados para lab computers

em Scielo Saúde Pública - SP


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A lab-made interface for acquisition of instrumental analog signals between 0 and 5 V at a frequency up to 670 kHz at the parallel port of a microcomputer is described. Since it uses few and small components, it was built into the connector of a printer parallel cable. Its performance was evaluated by monitoring the signals of four different instruments and similar analytical curves were obtained with the interface and from readings from the instrument' displays. Because the components are cheap (~U$35,00) and easy to get, the proposed interface is a simple and economical alternative for data acquisition in small laboratories for routine work, research and teaching.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An undergraduate organic lab experiment is described based on the preparation of two readily accessible hydrazones. The UV-visible spectra of these N-H acids and of their conjugate bases are employed to illustrate the importance of through-conjugation in determining their acid strength and their internal charge-transfer-band transitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The excitation energy transfer between chlorophylls in major and minor antenna complexes of photosystem II (PSII) was investigated using quantum Fourier transforms. These transforms have an important role in the efficiency of quantum algorithms of quantum computers. The equation 2n=N was used to make the connection between excitation energy transfers using quantum Fourier transform, where n is the number of qubits required for simulation of transfers and N is the number of chlorophylls in the antenna complexes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma optical emission spectrometry (ICP OES) are widely used in academic institutions and laboratories for quality control to analyze inorganic elements in samples. However, these techniques have been observed to underperform in sample nebulization processes. Most of the samples processed through nebulization system are discarded, producing large volumes of waste. This study reports the treatment and reuse of the waste produced from ICP OES technique in a laboratory of analytical research at the Universidade Federal do Ceará, Brazil. The treatment of the waste was performed by the precipitation of elements using (NH4)2CO3. Subsequently, the supernatant solution can be discarded in accordance with CONAMA 430/2011. The precipitate produced from the treatment of residues can be reused as a potential sample in undergraduate qualitative analytical chemistry lab classes, providing students the opportunity to test a real sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O transtorno fonológico é uma alteração de manifestação primária de causa indefinida que torna a fala ininteligível. A análise de parâmetros vocais torna-se importante no processo do diagnóstico deste transtorno, pois distúrbios de voz poderiam interferir na produção dos sons da fala. OBJETIVO: O objetivo deste estudo foi verificar as características vocais relacionadas à intensidade e freqüência fundamental - F0 - e seus índices de perturbação - jitter e shimmer - em crianças com transtorno fonológico. FORMA DE ESTUDO: clínico prospectivo com coorte transversal. MATERIAL E MÉTODO: Foram sujeitos 40 crianças distribuídas em dois grupos: 20 com transtorno fonológico e 20 sem alteração de fala e linguagem. Foram aplicadas provas de fonologia do Teste de Linguagem Infantil ABFW e de fala espontânea. Utilizou-se o Computer Speech Lab, para gravação e análise acústica das vogais /a/, /e/, /i/, por meio dos parâmetros vocais: freqüência fundamental, intensidade, jitter e shimmer. RESULTADOS: F0 - vogal /e/ é menor, em média, para o Grupo com Transtorno Fonológico (126Hz) e 237Hz no Grupo Controle. Para o shimmer e jitter não há evidência de que as médias do Grupo com Transtorno Fonológico sejam diferentes das do Grupo Controle (p= 0,191, p=0,865 respectivamente). Quanto à intensidade, há evidência de que a média diferencia os dois grupos (p= 0,002). CONCLUSÃO: A freqüência da vogal /e/ é menor no Grupo com Transtorno Fonológico. Existe diferença entre grupos para as médias da intensidade das vogais /a/, /e/ e /i/, sendo estas menores no Grupo com Transtorno Fonológico. Não foram encontradas diferenças entre grupos para as médias do jitter e do shimmer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ABSTRACT OBJECTIVE To describe the length of exposure to screens and the prevalence of consumption of meals and snacks by Brazilian adolescents in front of screens. METHODS We evaluated 74,589 12 to 17-year old adolescents from 1,247 schools in 124 Brazilian municipalities. A self-administered questionnaire was used. Its segment regarding nutrition contained questions about using TV, computers, and video game systems, having meals while watching TV, and consuming snacks in front of screens. Consumption of meals and snacks in front of screens was analyzed according to the following variables: geographical region, gender, age range, type of school (public or private), and school shift. The prevalences and their respective 95% confidence intervals were estimated under a complex sampling design. RESULTS A great deal of the adolescents (73.5%, 95%CI 72.3-74.7) reported spending two or more hours a day in front of screens. That habit was more frequent among male adolescents, private school students, morning shift students, and students from Brazil’s South region. More than half of the adolescents (56.6%, 95%CI 55.4-57.8) reported almost always or always having meals in front of TV, and 39.6% (95%CI 38.8-40.5) of them said they consumed snacks in front of screens exactly as often. Both situations were the most prevalent ones among the girls, who attended public schools and were from Brazil’s Midwest region. CONCLUSIONS Length of exposure to screens and consumption of meals and snacks almost always or always in front of screens are high among Brazilian adolescents. It is necessary to develop strategies aiming to reduce the length of screen use, considering the media reality that children and adolescents have been experiencing from earlier and earlier ages. That context must therefore be analyzed in an indissociable way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some viruses of the families Retroviridae, such as Human T Lymphotropic Virus (HTLV); Herpesviridae as the Cytomegalovirus (CMV) and Hepadnaviridae such as the Hepatitis B Virus (HBV) are liable to be co-transmitted with the Human Immunodeficiency Virus (HIV). Since prisoners are exposed to several and important risk factors involved in the transmission of HIV and the above mentioned viruses, male inmates from the penitentiary complex of Campinas, SP, Brazil, including HIV + and HIV - ones, were examined for the presence of HTLV-I and/or II antibodies; IgG and IgM anti-CMV antibodies, and the research of the superficial hepatitis B antigen (HBsAg). The presence of anti-HTLV-I and/or II was determined by the Western Blot (WB) technique, whereas IgG and IgM anti-CMV and the search of HBsAg were carried out by the Microparticle Enzyme Immunoassay (MEIA-Abbott Lab).With regard to anti-HTLV-I and/or II, 58.3% (14/24-Number of positive reactions/number of sera examined) were reactive among the anti-HIV positive sera. Conversely, only 12.5% (3/24) among the HIV- negative sera showed positive reactions to HTLV-I and/or II antibodies. When looking for IgG anti-CMV percentages of 97.7% (43/44) and 95% (38/40) were obtained for anti-HIV positive and negative sera, respectively. As to IgM anti-CMV antibodies 11.36% (5/44) and 2.5% (1/40) of reactive sera were found for anti-HIV positive and negative, respectively. The HBsAg was found in 12.8% (5/39) of the sera which were anti-HIV positive.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Animal and human rabies samples isolated between 1989 and 2000 were typified by means of a monoclonal antibody panel against the viral nucleoprotein. The panel had been previously established to study the molecular epidemiology of rabies virus in the Americas. Samples were isolated in the Diagnostic Laboratory of the Pasteur Institute and in other rabies diagnostic centers in Brazil. In addition to the fixed virus samples CVS-31/96-IP, preserved in mouse brain, and PV-BHK/97, preserved in cell culture, a total of 330 rabies virus samples were isolated from dogs, cats, cattle, horses, bats, sheep, goat, swine, foxes, marmosets, coati and humans. Six antigenic variants that were compatible with the pre-established monoclonal antibodies panel were defined: numbers 2 (dog), 3 (Desmodus rotundus), 4 (Tadarida brasiliensis), 5 (vampire bat from Venezuela), 6 (Lasiurus cinereus) and Lab (reacted to all used antibodies). Six unknown profiles, not compatible with the panel, were also found. Samples isolated from insectivore bats showed the greatest variability and the most commonly isolated variant was variant-3 (Desmodus rotundus). These findings may be related to the existence of multiple independent transmission cycles, involving different bat species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab.) for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

196 soros de crianças provenientes de dois educandários da Guanabara foram ensaiados quanto à presença de anticorpos para rubéola. através do teste de inibição de hemaglutinação. Apenas 24 crianças sem anticorpos foram encontradas e destas crianças susceptíveis um grupo foi vacinado com amostra Cendehill liofilizada do Lab. R.I.T. (Genval, Bélgica), sendo o outro grupo deixado como controle. Observou-se 100% de formação de anticorpos para rubéola no grupo vacinado. O alto nivel de anticorpos pré-vacinais encontrado sugere alta circulação do vírus cla rubéola em nosso meio.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To measure the thickness of adductor pollicis muscle in healthy adults. This measurement will be used as a nutritional anthropometric parameter in further studies. SUBJECTS AND METHOD: Four hundred and twenty-one healthy adults were studied, 209 men and 212 women, with ages ranging from 18 to 87 years, living in Rio de Janeiro. The adductor pollicis muscle was also studied in the human anatomy lab as well as in normal healthy volunteers using CAT scans and nuclear magnetic resonance imaging to ensure that only the adductor pollicis was included in measurement of muscle thickness with a Lange caliper. To standardize the measurement, the methodology was detailed, with subjects sitting with the dominant hand dangling over the homolateral thigh and the elbow bent at approximately a 90° angle. The Lange caliper was applied at a pressure of 10 g/mm², pinching the adductor pollicis muscle at the vertex of an imaginary angle between the thumb and the index finger. The average of 3 consecutive measurements was considered to be the muscle thickness. RESULTS: This study provides the first estimates of adductor pollicis thickness in normal healthy subjects as an anthropometric parameter. The normal values in the dominant hand for men were 12.5 ± 2.8 mm (mean ± SD), median 12 mm, and for women were 10.5 ± 2.3 mm, median 10 mm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

(1) In the period 1965/77 fertilizer consumption in Brazil increased nearly fifteen foild from circa 200,000 tons of N + P2O5 + K2O to 3 million tons. During the fifteen years extending from 1950 to 1964 usage of the primary macronutrients was raised by a factor of 2 only. (2) Several explanations are given for the remarkable increase, namely: an experimental background which supplied data for recommendations of rates, time and type of application; a convenient governmental policy for minimum prices and rural credit; capacity of the industry to meet the demand of the fertilizer market; an adequate mechanism for the diffusion of the practice of fertilizer use to the farmer. (3) The extension work, which has caused a permanent change in the aptitude towards fertilization, was carried out in the traditional way by salesmen supported by a technical staff, as well as by agronomists of the official services. (4) Two new programs were started and conducted in a rather short time, both putting emphasis on the relatively new technology of fertilizer use. (5) The first program, conducted in the Southern part of the country, extended lab and green house work supplemented by a few field trials to small land owners - the so called "operação tatú" (operation armadillo). (6) The seconde program, covering a larger problem area in the Northeast and in Central Brazil, began directly in field as thousands of demonstrations and simple experiments with the participation of local people whose involvement was essential for the success of the initiative; in this case the official extension services, both foreign and national sources of funds, and universities did participate under the leadership of the Brazilian Association for the Diffusion of Fertilizers (ANDA). (7) It is felt that the Brazilian experience gained thereof could be useful to other countries under similar conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The latex action of Euphorbia splendens var. hislopii (Christ's Crown) against snails Lymnaea columella, intermediate host of Fasciola hepatica, derived from irrigation ditches of the Station of Pisciculture at Universidade Federal Rural do Rio de Janeiro, was studied in the laboratory. Lab bioassays, using aqueous solutions of the latex, varying between 0.1 and 10 mg/l, have proven molluscicidal activity of the product collected on the same day the tests were performed, during the four seasons of the year, finding the following lethal concentrations (LC90): 1.51 mg/l in the spring; 0.55 mg/l in the summer; 0.74 mg/l in the fall and 0.93 mg/l in winter, after 24 h exposure of the snails, showing significant differences among the seasons of the year (ANOVA test, F = 11.01, G.L.= 3/33, p < 0.05), as well as among the concentrations (ANOVA test, F = 27.38, G.L.= 11/33, p < 0.05). In the summer, mortality reached 100% from concentration at 0.6 mg/l, the same during fall and in winter as of 1 mg/l, while in spring it only reached 100% mortality as of 2 mg/l. Mortality in the controls was low, reaching 5% in the summer and winter and 10% in the fall and spring. None of the samples died. During the assay, with an aqueous solution of the latex at a concentration of 5 mg/l, in order to check the time of duration of the product effect, in the laboratory, it was observed that the molluscicidal activity remained stable up to the 15th day after the beginning of the test with 100% mortality of L. columella, gradually losing its effect until the 23rd day, when we no longer observed animal mortality. In the control group, there was a random daily variation in mortality rate ranging 0-50% after 48 h of observation for 30 days.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.